Technical data
Battery-Charging Generator 6–55
6.17.2 Battery-charging generator drive – drive belt condition check
Preconditions
• Engine is stopped and starting disabled.
Belt condition check
1. Remove guard cover.
2. Check belt for contamination by oil, cracks, wear,
and signs of overheating.
3. Replace drive belt:
• If belt is oily;
• If belt shows signs of overheating;
• If ribs are broken around the entire
circumference (A);
• If ribs are broken around the entire
circumference and material is broken off in
some places (B) (→ Page 6 – 56).
4. Install guard cover.
M015560/00E 03-05 ©MTU