Technical data
Engine Governor (Electronic) Control System 6 – 63
6.21 Engine Governor (Electronic) Control System
6.21.1 ECU – Removal and installation
Preconditions
• Engine is stopped and starting disabled.
Special tools
Designation / Use Part No. Qty.
Connector pliers
Covering caps for Cannon sockets
ECU – Removal
1. Note or mark assignment of cables to connector
sockets.
2. Use connector pliers (2) to disengage the
bayonet union nuts (4) of the connectors (3) by
turning them counterclockwise.
3. Withdraw all connectors.
4. Close connector sockets with appropriate
covering caps (1).
5. Disconnect grounding strip from ECU grounding
pin .
6. Unscrew corresponding screws and remove ECU.
ECU – Installation
1. Follow reverse sequence of operations as described for removal. Ensure correct assignment of connectors
to sockets.
2. Use connector pliers to turn the bayonet union nuts of the connectors clockwise until they lock into place.
M015560/00E 03-05 ©MTU