Operating instructions
52 Battery-Charging Generator
Battery-charging generator drive drive belt
replacement
1. Remove guard cover.
2. Loosen locknut (2) and screws (1).
3. Release drive belt with tensioning nut (3) and
take off belt.
4. Check belt pulleys for cleanliness, remove
dirt, if any.
5. Fit new drive belt.
6. Tension drive belt with tensioning nut (3) and
check belt tension (
Page 6 50).
7. Tighten locknut (2).
8. Tighten screws (1).
9. Install guard cover.
10. Check drive-belt tension after 30 minutes and
again after 8 hours engine run time.
6.17.4 Battery-charging generator condition check
Preconditions
Engine is stopped and starting disabled.
Battery-charging generator condition check
1. Check securing screws of battery-charging generator for secure seating.
2. Tighten loose screw connections.
3. Check wiring (
Page 6 55).
M015403/00E 02-09 © MTU