Operating instructions

2 Operation
3.2 Putting the engine into operation after scheduled
out-of-service-period
Preconditions
Engine is stopped and starting disabled.
Putting the engine into operation
Item Task
Lube oil system Check oil level ( Page 6 35);
Cooling system Check engine coolant level ( Page 6 41);
Check charge-air coolant level (
Page 6 48).
Cooling system Preheat coolant with preheating unit.
Fuel prefilter Drain( Page 6 24).
Monitoring equipment Carry out lamp test (see manufacturers documentation).
Engine/generator control system Switch ON;
Select operating mode, e.g. MANUAL OPERATION, AUTOMATIC
OPERATION.
3.3 Starting the engine in manual mode
Preconditions
Generator is not connected to network.
External start interlock is not activated.
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury danger to life!
Before barring or starting the engine, ensure that nobody is in the danger zone.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
Wear ear protectors.
Preparation
Item Task
Operating mode selector switch
(if provided)
Change to manual mode.
Preheating pump (if provided) Switch ON.
M015403/00E 02-09 © MTU
www.generent.ru