Operating instructions
6 Operation
After emergency stop from LOP
Item Task
Switching cabinet, control
panel etc. (depending on
manufacturer)
Press button for alarm acknowledgement.
Audible and visual signalization stops.
3.8 After stopping the engine engine remains
ready for operation
After stopping the engine
Item Task
Engine/generator control system Select operating mode, e.g. MANUAL OPERATION, AUTOMATIC
OPERATION.
3.9 After stopping the engine putting the engine out of service
Preconditions
MTU Fluids and Lubricants Specification (A001061/..) is available.
After stopping the engine
Item Task
Cooling system Drain engine coolant ( Page 6 40);
Drain charge-air coolant (
Page 6 46) if:
freezing temperatures are expected and the engine is to remain out of
service for an extended period and coolant has no antifreeze additive;
the engine room is not heated;
the coolant is not maintained at a suitable temperature;
the antifreeze concentration is insufficient for the engine-room
temperature;
antifreeze concentration is 50% and engine-room temperature is below
-40
C.
Engine/generator control system S wit c h O FF.
Air intake and exhaust system If the engine is to remain out of service for more than 1 week, seal the engines
air and exhaust sides. If the engine is to remain out of service for more than
1 month, carry out preservation (
MTU Fluids and Lubricants Specification
A001061/..).
M015403/00E 02-09 © MTU