Maintenance Schedule Application Group 3B 4 5
W Item Task
W3 LT coolant pump Check relief bore for oil and water discharge and
obstructions (
Page 6 49).
W3 Engine coolant cooler Check cooler elements for external contamination (see
manufacturers documentation).
W3 Charge-air coolant cooler Check cooler elements for external contamination (see
manufacturers documentation).
W3 Coupling Check condition (see manufacturers documentation).
W3 Battery Check (see manufacturers information).
W4 HP pump Check relief bore for oil and fuel discharge and obstructions
(
Page 6 14).
W4 Air filter Replace ( Page 6 30).
W4 Starter Check condition ( Page 6 32).
W4 Battery-charging generator drive Check belt condition ( Page 6 50).
W4 Battery-charging generator drive Check and adjust belt tension ( Page 6 50).
W4 Battery-charging generator Check condition ( Page 6 52).
W4 Engine / generator mounts Check tightness of securing screws ( Page 6 53).
W4 Engine / generator mounts Check condition of resilient mounts ( Page 6 53).
W4 Engine wiring Check ( Page 6 55).
W4 ECU Check (visual inspection) ( Page 6 57).
W4 ECU Clean( Page 6 56).
M015403/00E 02-09 © MTU