Operating instructions

1.5 Auxiliary materials, fluids and lubricants, fire prevention and
environmental protection
Fire prevention
Rectify any fuel or oil leaks immediately; even splashes of oil or fuel on hot components can cause fires –
therefore always keep the engine in a clean condition. Do not leave cloths soaked with fluids and lubri‐
cants lying on or near the assembly or unit. Do not store inflammable material near the assembly or unit.
Do not weld pipes and components carrying oil or fuel! Before welding, clean with a nonflammable fluid.
When starting the engine with an external power source, connect the ground lead last and remove it first.
To avoid sparks in the vicinity of the battery, connect the ground lead from the external power source to
the ground lead of the engine or to the ground terminal of the starter.
Always keep suitable firefighting equipment (fire extinguishers) at hand and familiarize yourself with their
use.
Noise
Noise can lead to an increased risk of accident if acoustic signals, warning shouts or noises indicating
danger are drowned.
Wear ear protectors in work areas with a sound pressure level in excess of 85 dB (A).
Environmental protection and disposal
Modification or removal of mechanical or electronic components or the installation of additional compo‐
nents as well as the execution of calibration processes that might affect the emission characteristics of
the engine are prohibited by emission regulations. Emission control units/systems may only be main‐
tained, exchanged or repaired if the components used for this purpose are approved by MTU or equiva‐
lent components. Noncompliance with these guidelines might represent a violation of the Clean Air Act
and involves the termination of the operating license by the emission authorities. MTU does not accept
any liability for violations of the emission regulations. MTU will provide assistance and advice if emission-
relevant components are intended to be modified. The MTU Maintenance Schedules ensure the reliabili‐
ty and performance of MTU engines and must be complied with over the entire life cycle of the engine.
Use only fuel of prescribed quality to comply with emission limit values.
Dispose of used fluids, lubricants and filters in accordance with local regulations.
Within the EU, batteries can be returned free of charge to MTU FN / MTU Onsite Energy where they are
subjected to proper recycling procedures.
Auxiliary materials, fluids and lubricants
Use only fluids and lubricants that have been tested and approved by MTU.
The Fluids and Lubricants Specifications will be amended or supplemented as necessary. Before using
them, make sure you have the latest version. The latest version is also available at: http://www.mtu-on‐
line.com/mtu/mtu-valuecare/mtu-valueservice-Technische-Dokumentation.
Keep fluids and lubricants in suitable, properly designated containers. When using fluids, lubricants and
other chemical substances, follow the safety instructions that apply to the product. Take special care
when using hot, chilled or caustic materials. When using flammable materials, avoid all sparks and do
not smoke.
Used oil
Used oil contains harmful combustion residues.
Rub barrier cream into hands.
Wash hands after contact with used oil.