Operating instructions
7.18.2 Battery-charging generator – Check
Preconditions
☑ Engine is stopped and starting disabled.
WARNING
Compressed air
Risk of injury!
• Do not direct compressed-air jet at persons.
• Wear protective goggles / safety mask and ear protectors.
Battery-charging generator check
Item Diagnosis Task
Ventilation area (arrow) Clean None
Ventilation area (arrow) Dirty Clean
Battery-charging generator cleaning
Note: Dry-clean battery-charging generator only.
1. Remove thick dirt from battery-charging generator.
2. Blow out ventilation area (arrow) with compressed air until all dust is cleared.
M015675/05E 2011-10 | Task Description | 121
TIM-ID: 0000007377 - 001