Operating instructions

3. Insert feeler gauge with determined value
between valve bridge and valve-stem end
(A).
4. At the opposite valve-stem end (B), a feeler
gauge thicker by 0.05 mm should not fit,
otherwise adjust valve bridge balance.
M015675/05E 2011-10 | Task Description | 73