Operating instructions

Fault code Alarm text Meaning Task
364 STOP POWER STAGE
2
Solenoid valve or wiring or
ECU defective
Automatic engine shutdown.
1.
Check wiring.
2.
Try to re-start the engine
(→ Page 32).
3.
Contact Service.
365 STOP SOLENOID-WIR-
ING
Solenoid-valve wiring faulty;
Automatic engine shutdown.
1.
Check wiring.
2.
Try to re-start the engine
(→ Page 32).
3.
Contact Service.
381 TRAN.OUT1 PLANT
DEF
Binary transistor output
plant 1 defective
Contact Service.
382 TRAN.OUT2 PLANT
DEF
Binary transistor output
plant 2 defective
Contact Service.
383 TRAN.OUT3 PLANT
DEF
Binary transistor output
plant 3 defective
Contact Service.
384 TRAN.OUT4 PLANT
DEF
Binary transistor output
plant 4 defective
Contact Service.
385 TRAN.OUT 5 PLANT
DEF
Binary transistor output
plant 5 defective
Contact Service.
386 TRAN.OUT 6 PLANT
DEF
Binary transistor output
plant 6 defective
Contact Service.
M015675/06E 2013-04 | Troubleshooting | 51
TIM-ID: 0000003161 - 001