Operating instructions
347 – AL Open Load Cylinder A7
ZKP-Number: 18.004.546
Cause Corrective action
Disruption fault in injector cabling
to cylinder A7. Result: Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
348 – AL Open Load Cylinder A8
ZKP-Number: 18.004.547
Cause Corrective action
Disruption fault in injector cabling
to cylinder A8. Result: Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
349 – AL Open Load Cylinder A9
ZKP-Number: 18.004.548
Cause Corrective action
Disruption fault in injector cabling
to cylinder A9. Result: Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
350 – AL Open Load Cylinder A10
ZKP-Number: 18.004.549
Cause Corrective action
Disruption fault in injector cabling
to cylinder A10. Result: Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
351 – AL Open Load Cylinder B1
ZKP-Number: 18.004.550
Cause Corrective action
Disruption fault in injector cabling
to cylinder B1. Result: Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
352 – AL Open Load Cylinder B2
ZKP-Number: 18.004.551
Cause Corrective action
Disruption fault in injector cabling
to cylinder B2. Result: Misfiring.
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
MS150047/02E 2012-03 | Troubleshooting | 101