Operating instructions

506 – AL Low Starter Voltage
ZKP-Number: 14.500.906
Cause Corrective action
The battery voltage is too low for
the starting process.
u Check starter battery and cabling.
507 – AL POM Error
ZKP-Number: 14.500.907
Cause Corrective action
A general POM error occurred. u Replace POM.
508 – AL Wrong POM-ID
ZKP-Number: 14.500.908
Cause Corrective action
POM sends a different ID
number than expected.If alarm
occurs in combination with alarm
504, the resistor in the POM
cabling is missing.
u Check POM wiring harness.
519 – Oillevel Calibration Error
ZKP-Number: 10.158.921
Cause Corrective action
Error when writing the calibration
value into the Flash or SD
memory of the level sensor;
associated PV: AL Group 6 Mot
Bit 11
1. Check sensor and cabling, replace as necessary.
2. Contact Service.
525 – SD P-Lube Oil (R2)
ZKP-Number: 18.004.638
Cause Corrective action
Redundant lube oil pressure
sensor faulty; Short circuit or
wire break
u Check sensor and cabling, replace as necessary.
526 – SD T-Coolant (R2)
ZKP-Number: 18.004.639
Cause Corrective action
Redundant coolant temperature
sensor faulty; Short circuit or
wire break
u Check sensor and cabling, replace as necessary.
MS150047/02E 2012-03 | Troubleshooting | 109
TIM-ID: 0000018389 - 002