6.17 Auxiliary PTO
6.17.1 Bilge pump – Relief bore check
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury – danger to life!
• Take special care when working on a running engine.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
• Wear ear protectors.
Checking bilge pump relief bore
1. Check relief bores for oil and water dis‐
charge.
2. Stop engine (→ Page 74) and disable en‐
gine start.
3. Clean relief bores with a wire if dirty.
• Permissible water discharge: Up to 10
drops per hour
• Permissible oil discharge: Up to 5 drops
per hour
4. If discharge exceeds the specified limits:
Contact Service.
MS150047/02E 2012-03 | Task Description | 167
TIM-ID: 0000015791 - 003