Operating instructions

RAW WATER CIRCUIT (open circuit)
Number of cylinders 16
Raw water pump: Inlet pressure, min. L bar -0.2
Raw water pump: Inlet pressure , max. L bar 0.5
Pressure loss in external raw water system, max. L bar 0.7
LUBE OIL SYSTEM
Number of cylinders 16
Lube oil operating temperature before engine, from R °C 72*
Lube oil operating temperature before engine, to R °C 80*
Lube oil operating pressure before engine, from R bar 6
Lube oil operating pressure before engine, to R bar 8
Lube oil operating pressure, low idle (meas. point: before engine) R bar 2.0
FUEL SYSTEM
Number of cylinders 16
Fuel pressure at engine supply connection, min. (when engine is starting) L bar -0.1
Fuel pressure at engine supply connection, min. (when engine is running) L bar -0.3
Fuel pressure at engine supply connection, max. (when engine is starting) L bar 1.5
Fuel supply flow, max. R liter/min 30
GENERAL OPERATING DATA
Number of cylinders 16
Firing speed, from R rpm 80
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 16
Starter, rated voltage (standard design) R V= 24
STARTING (with compressed air/hydraulic starter)
Number of cylinders 16
Starting-air pressure before starter motor, min. R bar 8
Starting-air pressure before starter motor, max. R bar 10
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders 16
Longitudinal inclination, continuous max., driving end down (option: max.
operating inclinations)
L Degrees 15
Longitudinal inclination temporary max. drive side down (design: max. oper‐
ating inclinations)
L Degrees 22.5
60 | Product Summary | MS150047/02E 2012-03