Operating instructions
5.3 ADEC engine governor – Fault codes
29 – HI ETC Idle Speed too High
ZKP-Number: 18.004.206
Cause Corrective action
Idle speed of one of the
secondary turbochargers is too
high.
u Contact Service.
38 – AL ETC Speed Deviation
ZKP-Number: 18.004.205
Cause Corrective action
Speed of one of the secondary
turbochargers deviates from
primary turbocharger speed.
1. Reduce power.
2. Contact Service.
39 – AL ETC2 CutIn Failure
ZKP-Number: 18.004.204
Cause Corrective action
ETC2 could not be cut in. 1. Reduce power.
2. Contact Service.
81 – AL Rail Leakage
ZKP-Number: 18.004.046
Cause Corrective action
Pressure gradient in rail is too
low during starting or too high
during stopping (HP system
leaky or air in the system)
u Contact Service.
102 – AL Cons. Counter Defect
ZKP-Number: 18.004.624
Cause Corrective action
Consumption meter faulty. u Contact Service.
104 – AL Eng Hours Counter Defect
ZKP-Number: 18.004.623
Cause Corrective action
Hour meter faulty. u Contact Service.
86 | Troubleshooting | MS150047/02E 2012-03