Operating instructions

Number of cylinders 8
Number of inlet valves per cylinder 2
Number of exhaust valves per cylinder 2
LUBE OIL SYSTEM
Number of cylinders 8
Lube-oil operating temperature before engine, from R °C 85
Lube oil temperature before engine, to R °C 90
Lube oil operating pressure before engine, from R bar 5.5
Lube oil operating pressure before engine, to R bar 6.0
Lube oil operating pressure (low idle) (meas. point: before engine) R bar 2.0
FUEL SYSTEM
Number of cylinders 8
Fuel pressure at engine supply connection, min. (when engine is starting) L bar -0.1
Fuel pressure at supply connection to engine (when engine is running),
min.
L bar -0.3
Fuel pressure at engine supply connection, max. (when engine is starting) L bar 1.5
Fuel supply flow, max. R liter/min 15.5
GENERAL OPERATING DATA
Number of cylinders 8
Firing speed, from R rpm 80
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 8
Starter, rated voltage (standard design) R V= 24
STARTING (with pneumatic / hydraulic starter)
Number of cylinders 8
Starting air pressure before starter motor, min. R bar 16
Starting air pressure before starter motor, max. R bar 30
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders 8
Longitudinal inclination, continuous max. driving end down (Option: max.
operating inclinations)
L degree 15
Longitudinal inclination, temporary max. driving end down (Option: max. op‐
erating inclinations)
L degree 22.5
Longitudinal inclination, continuous max. driving end up (Option: max. oper‐
ating inclinations)
L degree 10
Transverse inclination, continuous max. (Option: max. operating inclina‐
tions)
L degree 22.5
30 | Technical Data | M015412/03E 2012-02
TIM-ID: 0000011012 - 001