Operator`s manual

701333-004 4-7
Configuring the 1330 in 3270 Mode
104 – Maximum Print Position (MPP)
Configuration Option 104 enables you to specify a maximum print position (MPP) value.
This value is the print position of the last character on the print line. The MPP range is
based on the following MPP-CPI chart. Valid values are 1 through the value shown in the
chart for each CPI. The default is 132.
PPM IPC
23101
85121
89151
0227.61
5221.71
46202
To specify an MPP value, follow the configuration procedure that begins on Page 4-1.
You can enter a different choice, or you can keep the current value by pressing Save.
If an Invalid message is displayed when you change the MPP, first change the CPI setting
using Configuration Option 102, then change the MPP.
105 – Form Length
Configuration Option 105 enables you to specify the number of lines per page that the
1330 will print. Valid values are 0 through 660 for 6 LPI and 0 through 880 for 8 LPI. The
values are based on a maximum allowable form length of 110 inches.
To specify the forms length, follow the configuration procedure that begins on Page 4-1.
You can enter a different value, or you can keep the current value by pressing Save.
106 – Line Spacing
Use Configuration Option 106 to specify whether the 1330 will print double line spacing.
Refer to “103 – Lines per Inch (LPI)” above for information on Option 103.
noitpO eciohC gninaeM
601
)elgniS(1eht,sitaht;301noitpOnideificepssaIPL
)tluafed(IPL8roIPL6tastnirp0331
)elbuoD(2eht,sitaht;2ybdedivid301noitpOsiIPL
IPL4roIPL3tastnirp0331
To specify your choice, follow the configuration procedure that begins on Page 4-1.
Enter your choice (1 or 2) and press Save.