Configuration 21
AES-VMUX/-SFP User Manual Rev. G
6.5.2 Example 2
Figure 6.4 Point to point 8 out and 8 back.- 2 Modules, 2 sites.
Both modules are used for embedding and de-embedding and the SDTI signal is connected in a
loop so one of the modules must be the clock master.
Table 6.7 Local module
Port Directions SW2 1-3 off, on, off
Master clock mode SW2.6 on
Demux start address SW1 1-4 off, off, on , off
Mux start address SW1 5-8 off, off, off, off
Table 6.8 Remote module
Port Directions SW2 1-3 off ,on ,off
Demux start address SW1 1-4 off, off, off, off
Mux start address SW1 5-8 off, off, on , off