connections against damage. Please note that this does not mean meters or registers
can be carried while supported only by the AMR transmitter or wiring.
3. CONNECTING AND OPERATING THE MUELLER AMR
TRANSMITTER
The AMR transmitter is preprogrammed prior to being attached to the meter. All pit set
units come with either 5’ or 25’ of wire attached and potted at the factory as specified. If
a retro fit is required, the wires should be spliced to the existing wires coming from the
register. Wire the red to red, green to green, and black to black wires using 3M UY2
Scotchlok splices with the E-9Y application tool.
Figure 2
If a new wall unit is being installed it can be directly mounted to any surface by using the
holes shown in Figure 2 and the appropriate screws. New pit installations can use the
mounting method described above or a ½” PVC pipe can be used in conjunction with the
PVC Installation Slot shown in Figure 2. This feature allows for quick easy installation
without the use of zip ties, wraps, tape, or adhesives. Two solid stops were included in
the PVC Installation Slot in order to prevent the wire from being pinched when the PVC
pipe is installed. For best performance the top of the transmitter should be placed
approximately six inches below the pit lid. A TRU-Readremote display can be used in
conjunction with the Translator register and AMR transmitter for visual remote readings if
desired. Refer to TRU-Read installation instructions below to attach both devices. When
wiring the TRU-Read to the Translator you must connect the red wire to the red terminal,
the green to green, and the black to black, Figure 2.