Installation Instructions

3
Pumper Cap Installation:
1. Confirm the hydrant is de-pressurized as described in steps 1-4 on
page 2.
2. Use Hydrant Wrench to remove existing Pumper Cap.
3. Install Inner Pumper Cap with plastic plug and tighten.
4. Place Sealed Electronics. Note Sky should be pointing towards the
sky and as parallel as possible to the ground. Also note the
location of the NFC antenna shown by the words NFC and arrow.
5. Place outer cap and tighten with washer and nut. Outer Pumper
Cap can be rotated in 60 degrees increments.
6. After the Pumper Cap and electronics have been installed, the
phone app can be used to checked reception. App will use existing
cellular modem and network to determine cellular reception in the area.