Operation Manual

www.hugo-mueller.de BA HUpro GB -22989- 2014-07-V03 - ED - A3 Seite 1
GB
Additional instruction master clock Site 1 / 2
PLEASE NOTE!!!
SAFETY INSTRUCTIONS
(SC 58.17 pro / SC 98.47 pro / SC 53.17 pro / SC 93.47 pro)
Please note the following for masterclock with time switch functionality:
This manual describes only masterclock features. Time switch relevant description can be
found in the standard time switch manual!
Only the connection diagram, initial operations and the safety instructions of this manual is
valid.
!!ATTENTION!! DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!!
=> Installation and assembly of electrical equipment must be carried out only by a skilled person!!!
=> Disconnect device from power supply for wiring and installation purposes!!!
=> Defective devices have to be put out of service immediately!!!
Connect the supply voltage/frequency as stated on the product!
Warranty void if housing opened by unauthorised person!
The electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if
external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with local building and electrical
codes!
The disposal of the device (and batteries) must be in accordance with the valid environmental and national law!
SC 58.07 pro (DIN rail mounting – master clock)
Technical data slave-clock-line (SL)
SC 58.07 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 35mA
Conn. terminals: 17 / 18
Max. number clocks: approx. 5 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The time switch is delivered in power back up mode (battery mode).
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode.
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to terminal no. 17 and 18 of the master clock.
SC 58.08 pro (DIN rail mounting – master clock)
Technical data slave-clock-line (SL)
SC 58.08 pro
Connection diagram
Connection sample
Number of lines: 1
Output voltage: Max. 250V~ (potential-free)
Output current: 1A
Conn. terminals: 2 / 8
Max. number clocks: Depends on the slave clocks
Pulse sequence: Normal operation = 1/min
During adjustment = ca. 6/min
Pulse length: 8 sec.
(Pulse sequence/length adjustable)
PLEASE NOTE: The two relays are
energized alternately every minute.
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to terminal no. 2 and 8 of the master clock.
Power supply slave-clock-line (SL) (See connection diagram on the left)
Connect power supply for clock motor(s) to terminals 1 / 9 and 3 / 7
SC 58.17 pro (DIN rail mounting – master clock with time switch functianality / weekly time switch)
Technical data slave-clock-line (SL)
SC 58.17 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 150mA
Conn. terminals: 17 / 18
Max. number clocks: approx. 20 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
Connection slave-clock-line (SL) => master clock (See
SC 98.47 pro (DIN rail mounting master clock with time switch functianality / yearly time switch)
Technical data slave-clock-line (SL)
SC 98.47 pro
Connection diagram
Number of lines: 1
Output voltage: 24VDC
Output current: 300mA
Conn. terminals: 35 / 36
Max. number clocks: approx. 40 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product!
(Master clock = terminals 22/23 / Time switch = terminals 4/5).
Connection slave-clock-line (SL) => master clock (See
SC 53.17 pro (19”-housing master clock with time switch functianality / weekly time switch)
Technical data slave-clock-line (SL)
SC 53.17 pro
Connection diagram
SC 53.17: 2 NU-Linie
The signal output for line 1 and line 2 can be configured
independently to emit pulses either every second or every minute!
NOTE! Power supply from a third party supplier:
The usage of a switched-mode power supply to drive the slave clock line
might disturb the reception of the FU 20.00 pro radio receiver. If the radio
receiver has no reception (the green LED on the bottom of the radio
receiver flashes rapidly or not at all) please connect GND of your
switched-mode power supply via an Y-capacitor with protective earth.
Number of lines: 2
Input USL: 24VDC (12VDC/48VDC/60VDC)
(Monitoring USL - switchable)
Output current: up to 1500mA for each line
(Depends on the power supply)
Conn. terminals: See conn. diagram on the left
Max. number clocks: approx. 200 slave clocks
(each line)
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
Module: NT 73 (Power adapter slave line)
Not included in delivery!
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product! (Terminals 32a und 32c).
Connection power supply the slave-clock-line (SL) => master clock
(See connection diagram on the left)
Depending on the specifications of the slave clocks, connect 12VDC; 24VDC; 48VDC; or
60VDC to terminals 26a and 26c.
Check polarity.
For voltages of slave clocks which differ from 24VDC, the dip switches on the PCB have to
be configured as stated within the table on the left.
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to:
Line 1 [L1] => terminals 24a und 24c
Line 2 [L2] => terminals 22a und 22c
Table dip switches
(Power supply monitoring of the slave-clock-
line)
SL S1 S2
SL S1 S2
12VDC ON ON
48VDC OFF ON
24VDC ON OFF
60VDC OFF OFF
SC 93.47 pro (19”-housing master clock with time switch functianality / yearly time switch)
Technical data slave-clock-line (SL)
SC 93.47 pro
Connection diagram
NOTE! Power supply from a third party supplier:
The usage of a switched-mode power supply to drive the slave clock line
might disturb the reception of the FU 20.00 pro radio receiver. If the radio
receiver has no reception (the green LED on the bottom of the radio
receiver flashes rapidly or not at all) please connect GND of your
switched-mode power supply via an Y-capacitor with protective earth.
Number of lines: 1
Input USL: 24VDC (12VDC/48VDC/60VDC)
(Monitoring USL - switchable)
Output current: up to 1500mA
(Depends on the power supply)
Conn. terminals: See conn. diagram on the left
Max. number clocks: approx. 200 slave clocks
Output signal: Pole changing pulse
Pulse sequence: Normal operation = 1/min
During adjustment = 10/min
Pulse length: 2 sec.
(Pulse sequence/length adjustable)
Module: NT 73 (Power adapter slave line)
Not included in delivery!
The display shows the power plug symbol [flashing ].
Press -button for 1 second. The display switches to automatic-mode
(Displaying the time and the current status of the slave-clock-line (SL)).
The master clock is already programmed with the current date and time and European
daylight savings time is activated. The slave-clock-line is preset as follows: Minute-line
activated / start time 12:00 / Slave-clock-line (SL) is stopped.
Power supply the master clock (See connection diagram on the left)
Connect the supply voltage/frequency as stated on the product! (Terminals 32a und 32c)
Connection power supply slave clockline => master clock
(See connection diagram on the left)
Depending on the specifications of the slave clocks, connect 12VDC; 24VDC; 48VDC; or
60VDC to terminals 26a and 26c.
Check polarity.
For voltages of slave clocks w
be configured as stated within the table on the left.
Connection slave-clock-line (SL) => master clock (See
Connect slave-clock-line to terminal no. 24a and 24c of the master clock.
Table dip switches
(Power supply monitoring of the slave-clock-
line)
SL S1 S2
SC S1 S2
12VDC ON ON
48VDC OFF ON
24VDC ON OFF
60VDC OFF OFF