Troubleshooting ProStar Operator’s Manual
57
56
5.0
Uncalibrated
The controller was not factory calibrated. Return the
controller to an authorized Morningstar dealer for
service.
5.2 LED Fault Indications
Solar Over-current
Error status LED: Flashing red. Battery status LEDs:
R/Y-G sequencing. When the ProStar’s rated input
current is exceeded, the unit will interrupt array
current until current falls below the maximum capacity.
While rare, if array current exceeds approximately
130% of the controller’s output current rating, this fault
can occur. The fault is generally related to fast, large
battery voltage transients (connecting a very heavy
or capacitive load like an inverter) that are faster than
the controller can regulate and it shuts off to protect
the circuitry. The controller will automatically clear the
fault, and attempt to re-start in 10 seconds.
Load Over-current
Error Status LED: Flashing red. Battery status LEDs:
R/Y-G sequencing. If the load current exceeds the
maximum load current rating, the ProStar will discon-
nect the load. The greater the overload, the faster the
load will be disconnected. A small overload could take
a few minutes to disconnect. The ProStar will attempt
to reconnect the load two (2) times. Each attempt
is approximately 10 seconds apart. If the overload
remains after two (2) attempts, the load will remain
disconnected until power is removed and re-applied.
Solar Short Circuit
Charging Status LED: OFF. Solar input power wires
are short-circuited. Charging automatically resumes
when the short is cleared.
Battery Reverse Polarity
No LED indication, the unit is not powered. No
damage to the controller will result. Correct the
mis-wire to resume normal operation.
Load Short Circuit
Error status LED: Flashing red. Battery status LEDs:
R/G-Y sequencing. Fully protected against load wiring
short-circuits. After two (2) automatic load reconnect
attempts (10 seconds between each attempt) the
ProStar will wait, and then automatically reconnect the
load, once the short is cleared.
Solar High Voltage Disconnect
Charging Status LED: R flashing. No battery
status indications. If the solar input open-circuit
voltage (Voc) exceeds the 60 Volt maximum rating, the
array will remain disconnected until the Voc falls safely
below the maximum rating.
Remote Temperature Sensor (RTS)
Error status LED: Flashing red. Battery status LEDs:
R/Y - G/Y sequencing. A bad RTS connection or a
severed RTS wire has disconnected the temperature
sensor during charging. Charging automatically re
-
sumes when the problem is fixed. To resume operation
without an RTS, disconnect all power to the ProStar
and then reconnect. If the controller is re-started with
the failure still present, the controller may not detect
that the RTS is connected, and the LEDs will not