Figure 11
Battery Temperature Sensor Installation
CAUTION - To reduce risk of injury, charge only deep-cycle lead acid, lead antimony, lead calcium,
gel cell or absorbed glass mat type rechargeable batteries. Other types of batteries may burst, causing
personal injury and damage. Never charge a frozen battery.
WARNING: RISK OF INJURY. To reduce the risk of injury, charge only properly rated (such as 6
V 12 V and 24 V ) lead-acid (GEL, AGM, Flooded, or Nickel Cadmium) rechargeable batteries. Other
battery types may burst, causing personal injury and damage.
WARNING: Explosion hazard during equalization, the battery generates explosive gases. Follow all
the battery safety precautions listed in this guide. Ventilate the area around the battery thoroughly using
ventilators with brushless motors and ensure that there are no sources of flame or sparks in the vicinity.
The Classic comes with a Battery temperature sensor which plugs into the jack beside the DC Terminal
connector labeled “Batt Temp”. Route the cable through the E-panel into the battery box. Pick a battery in
the middle of the bank and about half way up the side of the battery thoroughly clean a spot off on the
case. Then remove the protective tape from the sensor and adhere the temperature sensor to the battery.
Some manufacturers use a double wall case on the battery. For mounting a temp sensor to a double wall
battery case please refer to the battery manufacturer's recommended procedure.
Battery Temp Sensor
(included)
Cable Clamp for network
cables
USB connector
Ethernet connector