This mode will turn Aux 1 on when it reaches a set point based on battery voltage (V High) and turn it off
at another set point based on battery voltage (V Low). It also allows you to set a delay time in seconds the
Classic will wait before turning Aux 1 on after reaching the V High set point. It also allows you to set a
hold time in seconds the Classic will wait before turning Aux 1 off after reaching the V Low set point.
Aux 2 – Control Settings
Float Low
This mode will turn Aux 2 off whenever the Classic is in Float. Aux 2 will stay off until the Classic falls 3
tenths of a volt below the float voltage set point.
Float High
This mode will turn Aux 2 on whenever the Classic is in Float. Aux 2 will stay on until the Classic falls 3
tenths of a volt below the float voltage set point.
Day Light
This mode will turn on Aux 2 at sunrise and turn it off at sunset based on the PV input voltage.
Nite Light
This mode will turn on Aux 2 at sunset and turn it off at sunrise based on the PV input voltage.
Clipper Control
This mode was intended to control the MidNite Clipper. It will send out a PWM signal on AUX 2
whenever the controller is unloading the turbine because the battery is full or close to it. There are several
adjustment in this mode to optimize the Classic/Clipper combo; please see the Clipper manual for full
details.
Pv V on Low
This mode is PWM based and is just reverse logic of Pv V High. It would be comparable to using the NC
contacts of the relay used in Pv V High. It can be used that way with a solid state relay with NC contacts
for a failsafe load.
Pv V on High
This mode is PWM based and will PWM Aux 2 above a user set voltage (V High) based on the input
voltage to the Classic and stop when it hits a low voltage set point (V Low).
Toggle Test