Classic User Manual

Classic owner’s manual Rev H 2056
40 | P a g e 1 0 - 0 0 1 - 1 R E V : H
SOC % LOW Battery State of Charge Active LOW
SOC % HIGH Battery State of Charge Active HIGH
GFP TRIP HIGH Ground Fault sets AUX1 HIGH for 0.1 seconds repeatedly
VENT FAN LOW Aux1 on below setpoint
VENT FAN HIGH Aux1 on above setpoint
FLOAT LOW Aux1 off when in Float
FLOAT HIGH Aux1 on when in Float
CLIPPER CONTROL PWM Control for Clipper
DAY LIGHT Aux1 on at dawn off at dusk
NITE LIGHT Aux1 on at dusk off at dawn
TOGGLE TEST Aux1 cycled 1 sec interval
Pv V ON LOW Aux1 on below Pv in setpoint
Pv V ON HIGH Aux1 on above Pv in setpoint
WASTE NOT LO Divert based on charge state lo
WASTE NOT HI Divert based on charge state hi
LOW BAT DISC Disc load based on bat volt
DIVERSION Slow Diversion control
Aux 2 Function. Output/Input
OUTPUT = 12V/0V Signal / 500Hz PWM
WIZBANG JR Current Shunt Option
FORCE FLOAT IN IN > 6V Forces Float
LOGIC INPUT 2 IN < 2V = Resting or IN > 6V = Charge
LOGIC INPUT 1 IN > 6V = Resting or IN < 2V = Charge
FLOAT LOW Aux2 off when in Float
FLOAT HIGH Aux2 on when in Float
DAY LIGHT Aux2 on at dawn off at dusk
NITE LIGHT Aux2 on at dusk off at dawn
CLIPPER CONTROL PWM Control for Clipper
Pv V ON LOW PWM sig below Pv in setpoint
Pv V ON HIGH PWM sig above Pv in setpoint
TOGGLE TEST Aux2 cycled 1 sec interval
WASTE NOT LO PWM divert rltvchg state lo
WASTE NOT HI PWM divert rltvchg state hi
DIVERSION LO PWM Divert on Bat voltage lo
DIVERSION HI PWM Divert on Bat voltage hi
To set/ change threshold voltage as well as time do the following:
When in the function you wish to use press the right soft button
This will take you to the VOLTS menu here is where you set your threshold voltage
Use the left and right arrow keys to navigate through the options
Use the up and down arrow keys to raise or lower the threshold voltage
To change the time press again the right soft button to get to the TIME menu
In this menu do the same as you did in the VOLTS menu, until desired adjustments are made
Press ENTER to save