Classic User Manual

Classic owner’s manual Rev H 2056
66 | P a g e 1 0 - 0 0 1 - 1 R E V : H
Electrical Specifications
Model
Classic150
Classic200
Classic250
Operating Volts in
150VDC
200VDC
250VDC
Max Hyper VOC
150+battery
200+battery
250+battery
*Battery Charge Volts
12-93 volts
12-93 volts
12-93 volts
**Absolute Current
Output at 25°C
96a at 12v battery
94a at 24v battery
83a at 48v battery
74a at 12v battery
70a at 24v battery
65a at 48v battery
60a at 12v battery
62a at 24v battery
55a at 48v battery
De-rate current
at 40°C+
80 amperes
66 amperes
52 amperes
Environment
-40c to 40c
Dimensions of Classic
14.87”X 5.95”X 4.00” 378mm X 151mm X 102mm
Dimensions of Box
19.00”X 8.50”X 5.70” 483mm X 216mm xX145mm
Shipping Weight
11.5 lb 4.9 kg
NOTE: Current output ratings were measured with 75% of the PV array’s VOC (Open Circuit Voltage)
*NOTE: Calculated by adding battery voltage to the maximum input operating voltage (48V battery max)
* **NOTE: Measurement Accuracies: +- 0.12v, offset calibration adjustment maybe necessary