MidNite Classic Specifications

12 Through 72 volts on Classic's. Lite requires PC or MNGP to program above 48V
Classic 150 and 150 Lite = 96A on 12V, 94A on 24V and 86A on 48V battery
Classic 200 and 200 Lite = 79A on 12V, 78A on 24+48V and 65A on 72V battery
Classic 250 and 250 Lite = 61A on 12V, 62A on 24V, 55A on 48V and 43A on 72V battery
Classic150 = 150V + HyperVOC (battery voltage up to 48V) Example 150V + 48V = 198VOC
Classic200 = 200V + HyperVOC (battery voltage up to 48V)
Classic250 = 250V + HyperVOC (battery voltage up to 48V) NOTE: See HyperVOC at bottom
98% (Typical system)
2.5W
Zero - Internal relay for reverse current
Low Battery voltage disconnect and re-connect of loads fully
programmable with 2 Auxiliary outputs to control external load
disconnect /re-connect switches
Standard all models - Extended VOC range for cold climates
Standard on Classic, 0.1 second detect and trip speed - Not available on the Lite
Standard all models - resettable, no fuse to blow
Bulk, Absorb, Float as well as Equalization
10-100VDC
Adjustable Voltage and Duration, Manual or Auto
Protected to Max VOC
Fully protected
Fully protected
Fully protected
Automatic when BTS is installed, Adjustable mV per degree C per
2V cell
2 Auxiliary outputs, Aux1 can be 12V out or dry contact, Aux2 is
12V out or Logic IN
Graphical display - MNGP (NOTE: MNGP is an option on the Classic Lites)
Standard 4 conductor phone cable, no hub needed
RS232, Ethernet and ModBus openly published protocol
Display can be relocated and a second display can be added
Local Application software included allows viewing and control from
the network or over the Internet. MyMidNite.com - Online status monitoring
Internet Ready
380 days of daily history, 24 hours of data at 5 minute intervals
Standard on all models, requires a PC or MNGP on the Lite
Requires 2 pole input and output breakers
Minimum of -40C to 50C - Controller will auto derate as temperature
rises above 25C
Indoor type 1
Single 1" on the Left and Right. Two 1" on the bottom - 35MM hole
5 Year standard
12 Lbs. (5.45 kgs) - 14.9" x 6" x 4" (378MM x 152MM x 102MM)
19" x 8.5" x 5.7" (482.6MM x 215.9MM x 144.78MM)
MNGP (Display), 3ft networking cable
Listed by ETL for US & Canada, CE Certied, FCC Class B
12 Through 120 volts
56A on 12V, 58A on 24V, 50A on 48V and 35A on 120V battery
250V + HyperVOC (battery voltage up to 48V)
NOTE: See HyperVOC at bottom
98% (Typical system)
2.5W
Zero - Internal relay for reverse current
Low Battery voltage disconnect and re-connect of loads fully
programmable with 2 Auxiliary outputs to control external load
disconnect /re-connect switches
Standard - Extended VOC range for cold climates
Standard, 0.1 second detect and trip speed
Standard - resettable, no fuse to blow
Bulk, Absorb, Float as well as Equalization
10-150VDC
Adjustable Voltage and Duration, Manual or Auto
Protected to Max VOC
Fully protected
Fully protected
Fully protected
Automatic when BTS is installed, Adjustable mV per degree C per
2V cell
2 Auxiliary outputs, Aux1 can be 12V out or dry contact, Aux2 is 12V
out or Logic IN
Graphical display - MNGP
Standard 4 conductor phone cable, no hub needed
RS232, Ethernet and ModBus openly published protocol
Display can be relocated and a second display can be added
Local Application software included allows viewing and control from
the network or over the Internet. MyMidNite.com - Online status monitoring
Internet Ready
380 days of daily history, 24 hours of data at 5 minute intervals
Standard
Requires 2 pole input and output breakers
Minimum of -40C to 50C - Controller will auto derate as temperature
rises above 25C
Indoor type 1
Single 1" on the Left and Right. Two 1" on the bottom - 35MM hole
5 Year standard
12 Lbs (5.45 kgs) - 14.9" x 6" x 4" (378MM x 152MM x 102MM)
19" x 8.5" x 5.7" (482.6MM x 215.9MM x 144.78MM)
MNGP (Display), 3ft networking cable
Listed by ETL for US & Canada, CE Certied Listed, FCC Class B Listed
Nominal Battery Voltage
Maximum Output Current
PV Open Circuit Voltage VOC
(NOTE: See HyperVOC at bottom
Power Conversion Eciency
Maximum Stand-By Self-Consumption (12V)
Reverse Current At Night
Low Battery Voltage
Hyper VOC
Arc Fault Protection
Ground Fault Protection
Charging Regulation
Battery Voltage Regulation Set Points
Equalization Charging
PV Reverse Polarity
Battery Reverse Polarity
Battery Over Voltage
Battery Short Circuit
Battery Temp Compensation
Programmable Auxiliary Control Output
Status Display
Networking Cabling
Communications
Remote Display
Remote Monitoring And Control
Internet Ready
Data Logging
Wind And Hydro Applications
Positive Ground Applications
Operating Temperature
Environmental Rating
Conduit knock Outs
Warranty
Weight & Dimensions
Shipping Dimensions HxWxD
Options
Certications
HyerVOC: A non-operative VOC safety zone over and above the maximum input voltage for cold climates.
Classic and Classic Lite 150, 200 or 250 Classic 250KS
CLASSIC AND CLASSIC LITE SPECIFICATIONS
www.midnitesolar.com 360-403-7207 17722 - 67th Ave NE, Arlington, WA 98223