Just the Facts for the Classic (continued)
19 | P a g e 10- 2 0 9 - 1 R E V : D
Auto Equalization (AUTO EQ)
The Classic can be set up to automatically equalize your batteries periodically, programmed as days between
Equalization and the number of days the Classic will try to finish the programmed equalization charge cycle.
To set up Auto EQ go into the CHARGE menu and highlight “EQ” and press “Enter”. Now press the SOFT RIGHT
key labeled "AUTO EQ". Pressing the AUTO EQ soft key enters the Auto EQ setup menu screen. The left side of
the EQ setup menu will show and select the number of days, or "interval” between auto EQ charge cycles. If set to
zero (0), it will display MANUAL which is the same thing as DISABLED.
Figure 12
On the right side of the Auto EQ setup menu is the number of DAYS that the Auto EQ will retry if it does not finish
the number of Hours and Minutes the Classic has been programmed to EQ for during the first day. For instance you
set the Auto EQ for an interval of every 30 days and the RE-TRY for 3 days. Then the first day it attempts an EQ the
Classic only accumulates 1 hour of a 2 hour EQ cycle, the next day the Classic will re attempt the EQ cycle. If the
Classic still didn't finish the EQ cycle on the 2nd day of its 3 allotted re-try days, it will have one more day to try to
finish the Equalize cycle. After this, if it did not complete the 2 hours of EQ time, it will not continue another day.
The Classic will show “EQ DONE" on the status screen until either the start of the next day or until the user presses
a button on the MNGP to stop it earlier.
At the bottom of the AUTO EQ screen shows the time, in hours and minutes, that the EQ is set for.
Pressing the Soft Right key, labeled "VIEW", takes you to a screen where you can view the interval and re-try
counters (timers).
Viewing Logged Data
The Classic logs 380 days’ worth of data in its memory. The data logging in the Classic has two modes and
frequency of data capture.