Morningstar ProStar MPPT Manual

Operation
42
the “boost” cycle for sealed cells can be disabled by setting
the equalize setting switch to manual, if required.
Battery Charge Settings
Preset ProStar MPPT battery charging options are shown in
tables 4-1 and 4-2 below. All voltage settings listed are for
nominal 12 Volt batteries. Multiply the voltage settings by
two (2) for 24 Volt batteries.
NOTE: These settings are general guidelines for
use at the operator’s discretion. The ProStar MPPT can
be programmed to satisfy a wide range of charging parameters,
but only the battery manufacturer can recommend optimal
settings for their products.
DIP
S
witch
S
ettings
4
-5-6
B
attery
T
ype
A
bsorp.
S
tage
(
volts)
F
loat
S
tage
(
volts)
E
qualize
S
tage
(
volts)
A
bsorp.
T
ime
(
mins)
E
qualize
T
ime
(
mins)
E
qualize
T
imeout
(
mins)
E
qualize
I
nterval
(
days)
off-off-off 1 - Sealed* 14.00 13.70
150
off-off-on 2 - Sealed* 14.15 13.70 14.40 150 60 120 28
off-on-off 3 - Sealed* 14.30 13.70 14.65 150 60 120 28
off-on-on 4- AGM/Flooded 14.40 13.70 15.10 180 120 180 28
on-off-off 5 - Flooded 14.60 13.50 15.30 180 120 180 28
on-off-on 6 - Flooded 14.70 13.50 15.40 180 180 240 28
on-on-off 7 - L-16 15.40 13.40 16.00 180 180 240 14
on-on-on 8 - Custom Custom Custom Custom Custom Custom Custom Custom
* “Sealed” baery type includes gel and AGM baeries
* "Sealed" battery types include gel and AGM batteries
Table 4.1. Battery charging settings for each selectable battery type
Shared Settings Value Units
Absorption Extension Voltage 12.50 volts
Absorption Extension Time Absorption Time + 30 minutes
Float Exit Time-out 30 minutes
Float Cancel Voltage 12.30 volts
Equalize Time-out Equalize Time + 60 minutes
Temperature Compensation Coefficient - 5
millivolts / °C
/ cell
Table 4.2. Battery settings that are shared among all battery types