Parallel Host Bus Timing Table
Symbol Paramete
r
Min Max Units
READ (See Notes)
t
AS
Address Setup 5 - ns
t
AH
Address Hold
5 - ns
t
CS
Chip Select Setup
5 - ns
t
CH
Chip Select Hold 0 - ns
t
RD
RD Strobe Width 77 - ns
t
DD
Read Data Delay 10 25 ns
t
DRH
Read Data Hold 5 - ns
WRITE (See Notes)
t
AS
Address Setup 5 - ns
t
AH
Address Hold
5 - ns
t
CS
Chip Select Setup 0 - ns
t
CH
Chip Select Hold 10 - ns
t
WT
WT Strobe Width 15 - ns
t
DS
Write Data Setup (see Note 4) 15 20 ns
t
DWH
Write Data Hold (see Note 5) 5 - ns
Notes:
1. When the host executes consecutive Rx FIFO reads, a minimum delay of 2 times the internal CPU clock
cycle plus 15 ns (85.86 ns at 28.224 MHz) is required from the falling edge of RD to the falling edge of the
next Host Rx FIFO RD clock.
2. When the host executes consecutive Tx FIFO writes, a minimum delay of 2 times the internal CPU clock
cycle plus 15 ns (85.86 ns at 28.224 MHz) is required from the falling edge of WT to the falling edge of the
next Host Tx FIFO WT clock.
3.
t
RD'
t
WT
= t
CYC
+ 15 ns.
4.
t
DS is measured from the point at which both CS and WT are active.
5.
t
DWH is measured from the point at which either CS and WT become active.
6. Clock Frequency = 1.8432 MHz clock.
Parallel Host Bus – Read Parallel Host Bus - Write