Contact us For all enquiries, please call 0844 871 1525 Email: info@baxi.co.uk Visit: www.baxi.co.uk Please note calls may be monitored or recorded Pocket Technical Guide Open Monday - Friday, 8am - 6pm Saturdays & Bank Holidays, 8.30am - 2pm We are closed on Christmas Day & New Year’s Day Pocket Technical Guide Baxi, Brooks House, Coventry Road, Warwick CV34 4LL www.baxi.co.uk This Brochure is printed on paper sourced from well managed forests and controlled sources.
Welcome Notes Useful contacts Welcome to your pocket technical guide Notes Our technical guide is designed to assist you with the installation and servicing of our boilers providing you with helpful technical information in one easy reference booklet. We have an extensive range of courses available to you and we would strongly encourage you to take a look at page 58 to see how we can help support you and your business.
Contents Contents Introduction History of Baxi Innovative THINK technology Overview of the range Useful information Efficiency ratings Sales order codes Flue terminal positioning The Baxi range of boilers 4 5 6-7 8 9 10-13 Duo-tec Combi GA Flue groups, technical specifications & control options 14-21 Neta-tec Combi GA Flue groups, technical specifications & control options 22-29 Megaflo System Compact GA Flue groups, technical specifications & control options 30-37 Baxi Solo HE A Flue group
History of BAXI The brand that stands for quality and innovation A firm favourite with homeowners and installers alike, Baxi is one of Europe’s largest and longest-established boiler manufacturers. We have over 150 years of engineering experience – so we know a thing or two about how to do it right. We’re very proud not only of our long heritage of quality and innovation, but also that we continue to manufacture here in the UK.
Innovative THINK technology Innovative THINK technology – the heart of every Baxi GA boiler Our world-beating technical innovation is focused on delivering years of reliable and economical service and the maximum environmental benefit. Take our pioneering THINK technology, for example, found at the heart of every boiler in the Baxi GA range.
Overview Overview An at a glance guide to our new boilers, the key features available with each model and their benefits to you and your customer Features and benefits Gas Adaptive Technology Automatic set-up for faster and easier installation Wide modulation range Reduces wear and tear, and gas usage Front component access For quicker and easier servicing Two years parts and labour warranty* For peace of mind Pre-plumbing jig For faster and easier installation Cupboard fit For more flexible and discreet
Overview Baxi Duo-tec Baxi Neta-tec Combi GA Baxi Megaflo System Compact GA Baxi Solo HE A 1:7 1:5 1:7 1:3 Combi GA † For technical enquiries e-mail technical.helpline@bdrthermea.com X8013 - Technical pocket guide DL v14_post proof.
Efficiency ratings Efficiency ratings chart 2005/2009 SEDBUK 2005 (%) SEDBUK 2009 (%) Baxi Duo-tec Combi 24 GA (NG/LPG) 91.1 / 93.2 88.9 / 91.0 Baxi Duo-tec Combi 33 GA (NG/LPG) 91.1 / 93.2 89.0 / 90.9 Product Baxi Duo-tec Combi GA Baxi Duo-tec Combi 28 GA (NG/LPG) 91.1 / 93.2 Baxi Duo-tec Combi 40 GA (NG/LPG) 91.1 / 93.2 Baxi Neta-tec Combi GA 88.9 / 91.0 88.9 / 90.9 Baxi Neta-tec Combi 24 GA (NG/LPG) 91.1 / 93.2 88.9 / 91.0 Baxi Neta-tec Combi 33 GA (NG/LPG) 91.1 / 93.2 89.0 / 90.
Sales order codes Sales order codes Product Baxi Duo-tec Combi GA Sales Order Code Baxi Duo-tec Combi 24 GA (NG/LPG) 720117801 Baxi Duo-tec Combi 33 GA (NG/LPG) 720118201 Baxi Duo-tec Combi 28 GA (NG/LPG) Baxi Duo-tec Combi 40 GA (NG/LPG) 720118001 720118401 Baxi Duo-tec Combi GA Standard Flue 720598701 Baxi Neta-tec Combi 24 GA (NG/LPG) 720023001 Baxi Neta-tec Combi 33 GA (NG/LPG) 720023201 Baxi Neta-tec Combi GA Baxi Neta-tec Combi 28 GA (NG/LPG) Baxi Neta-tec Combi 24 GA (NG/LPG) & Std F
Flue options Flue options J,K R M I T U N I F L B G A I Likely flue positions requiring a flue terminal guard A 1 B1 C1 D2 E2 F2 G2 H2 I J K K L Terminal Position with Minimum Distance (mm) Above an opening, air brick, opening window etc 300 Directly below an opening, air brick, opening windows, etc Horizontally to an opening, air brick, opening window etc Below gutters, soil pipes or drain pipes 300 300 25 (75) Below eaves 25 (200) From a vertical drain pipe or soil pipe 25 (1
Flue options J,K U B A I R M I T U N F L D E C I B G A I A I H A S I F J,K H Likely flue positions requiring a flue terminal guard D E C A I H M A S I F J,K H Terminal Position with Minimum Distance Vertically from a terminal on the same wall N Horizontally from a terminal on the same wall S From adjacent opening window (vertical only) R T U (mm) 1500 300 From adjacent wall to flue (vertical only) Adjacent to windows or openings on pitched and flat roofs Bel
Flue options Flue options 300 min Terminal Assembly Top View Rear Flue Property Boundary Line NOTE: The distance from a fanned draught appliance terminal installed parallel to a boundary may not be less than 300mm, in accordance with the diagram above. Plume Displacement Kit Air Inlet Opening Window or Door 150mm MIN. IMPORTANT: If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors. 12 X8013 - Technical pocket guide DL v14_post proof.
Flue options Plume Displacement Kit permissible lengths NOTE: If using a Plume Displacement Kit please refer to the shaded areas of the graphs below for maximum permissible PDK lengths.
Duo-tec Combi GA Baxi Duo-tec Combi GA 5mm Min 5mm Min 450mm 170mm 170mm Min (300mm Min if using 80/12 25mm flueing system m) 106mm At Atleast least 1.5° 1.5° 450mm 450mm MinMin For servicing For servicing purposes purposes 763mm 150mm Min 5mmMin Min 5mm 345mm* 345mm* In operation In operation *355mm with control panel flap Clearances Above: Left: Right: 175mm 5mm 5mm Below: Front 150mm** 5mm (in operation) 450mm (for servicing) **This is MINIMUM recommended dimension.
st 1.5° Duo-tec Combi GA Flue lengths Flue Group (diameter) Flue Group A (60/100) Flue Group G (80/125) Flue Group N (80/80) Horizontal or Vertical (H/V?) H&V H&V H&V Max. Permissible length 10m 20m 15m Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.5m, 93° = 1.0m. Multifit Flue Group A – (60mm/100mm Concentric flue) horizontal and vertical options Part No. 720599401 Part No. 720598701 Part No. 720642701 Part No. 720644201 Part No. 5111068 Part No.
Duo-tec Combi GA Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.5m, 93° = 1.0m. Multifit Flue Group G – (80mm/125mm Flue systems) horizontal and vertical options Part No. 5118580 Horizontal Flue Kit 685mm Part No. 5118588 Part No. 5118584 1m Flue Extension Kit Part No. 5118610 Part No. 5118597 Bend (pair) 135˚ Part No. 5111078 Bend 91.5˚ Flue Support Bracket 125mmØ Vertical Flue Terminal 80/125 (Black) Part No. 246143 Part No. 5122151 Part No.
Duo-tec Combi GA Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.25m, 93° = 0.5m. Multifit Flue Group N – (80mm Twin Flue systems) horizontal and vertical options Part No. 5111087 Flue Extension (pair, includes 2 brackets) Part No. 5111084 Part No. 5111072 Flue Bend (pair) 90˚ Part No. 5120172 Part No. 5111086 Flue Bend (pair) 135˚ Part No.
Duo-tec Combi GA For Plume Displacement Kit permissible flue lengths please see page 13. 500mm Min. IMPORTANT: If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors. The inlet of the PDK MUST be at least 300mm above ground or balcony level or any projection or ledge. A guard must be fitted where the inlet is below 2 metres. Flue options White Black Plume Displacement Kits Ø 60/100mm - Multifit Flue Group A Part No. 720627001 Part No.
Duo-tec Combi GA Notes For technical enquiries e-mail technical.helpline@bdrthermea.com 19 X8013 - Technical pocket guide DL v14_post proof.
Duo-tec Combi GA Technical data Appliance Type C13, C33, C43, C53 Appliance Category CAT I 2H 3P Heat Input CH (Net) Max 24 model kW 20 28 model kW 24 33 model kW 28 40 model kW 32 Heat Output CH (Condensing) Max 24 model kW 21.2 28 model kW 25.3 33 model kW 29.6 40 model kW 33.8 Heat Output DHW 24 model 28 model 33 model 40 model kW kW kW kW Min 3.5 3.9 4.8 5.9 Min 3.7 4.1 5.1 6.2 Max 24 28 33 40 NATURAL GAS ONLY ! (Natural Gas - G20) Max Gas Rate (After 10 mins) 24 model m3/h 2.54 28 model m3/h 2.
Duo-tec Combi GA Clearances copper tails 175mm Min 150mm Min* 450mm Min Above Casing Below Casing Front (For Servicing) 5mm Min Front (In operation) L.H. Side R.H. Side 5mm Min 5mm Min *This is MINIMUM recommended dimension. Greater clearance will aid installation and maintenance. NOx Class 5 DHW Circuit Pressures Max Operating Min Operating Flow Rates DHW Flow @ 30o CRise DHW Flow @ 35o CRise Min Working DHW Flow bar 8 0.15 (24) (28) (33) (40) l/min l/min l/min l/min 10.9 12.9 15.3 18.3 9.
Neta-tec Combi GA Baxi Neta-tec Combi GA 390mm 5mm Min 5mm Min 162mm 175mm Min (300mm Min if using 80/125mm flueing system) 106mm At least At least 1.5° 1.5° 450mm Min Min 450mm Forservicing servicing For purposes purposes 700mm 5mmMin Min 5mm 150mm Min 290mm* 290mm * In operation In operation *300mm with control panel flap Clearances Above: Left: Right: 175mm 5mm 5mm Below: Front 150mm** 5mm (in operation) 450mm (for servicing) **This is MINIMUM recommended dimension.
east 1.5° Neta-tec Combi GA SEDBUK Flue lengths Flue Group (diameter) Flue Group A (60/100) Flue Group G (80/125) Flue Group N (80/80) Horizontal or Vertical (H/V?) H&V H&V H&V Max. permissible length 10m 20m 15m Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.5m, 93° = 1.0m. Multifit Flue Group A – (60mm/100mm Concentric flue) horizontal and vertical options Part No. 720870201 Neta-tec Horizontal Telescopic Flue Kit (Black terminal) Part No. 5111068 Part No.
Neta-tec Combi GA Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.5m, 93° = 1.0m. Multifit Flue Group G – (80mm/125mm Flue systems) horizontal and vertical options Part No. 5118580 Horizontal Flue Kit 685mm Part No. 5118588 Part No. 5118584 1m Flue Extension Kit Part No. 5118610 Part No. 5118597 Bend (pair) 135˚ Part No. 5111078 Bend 91.5˚ Flue Support Bracket 125mmØ Vertical Flue Terminal 80/125 (Black) Part No. 246143 Part No. 5122151 Part No.
Neta-tec Combi GA Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.25m, 93° = 0.5m. Multifit Flue Group N – (80mm Twin Flue systems) horizontal and vertical options Part No. 5111087 Flue Extension (pair, includes 2 brackets) Part No. 5111084 Part No. 5111072 Flue Bend (pair) 90˚ Part No. 5120172 Part No. 5111086 Flue Bend (pair) 135˚ Part No.
Neta-tec Combi GA For Plume Displacement Kit permissible flue lengths please see page 13. 500mm Min. IMPORTANT: If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors. The inlet of the PDK MUST be at least 300mm above ground or balcony level or any projection or ledge. A guard must be fitted where the inlet is below 2 metres. Flue options White Black Plume Displacement Kits Ø 60/100mm Part No. 720627001 Part No. 720622901 Part No.
Neta-tec Combi GA Notes For technical enquiries e-mail technical.helpline@bdrthermea.com 27 X8013 - Technical pocket guide DL v14_post proof.
Neta-tec Combi GA Technical data Appliance Type C13, C33, C43, C53 Heat Input CH (Net) Max 24 model kW 20 28 model kW 24 33 model kW 28 Heat Output CH (Condensing) Max 24 model kW 21.2 28 model kW 25.3 33 model kW 29.6 Heat Output DHW Max 24 model kW 24 28 model kW 28 33 model kW 33 Min 3.5 3.9 4.8 Min 3.7 4.1 5.1 NATURAL GAS ONLY ! (Natural Gas - G20) Max Gas Rate (After 10 mins) 24 model m3/h 2.54 28 model m3/h 2.96 33 model m3/h 3.
Neta-tec Combi GA Clearances Above Casing Below Casing Front Front L.H. Side R.H. Side copper tails 175mm Min 150mm Min* 450mm Min (For Servicing) 5mm Min (In Operation) 5mm Min 5mm Min : *This is MINIMUM recommended dimension. Greater clearance will aid installation and maintenance. NOx Class 5 CO2 N.G. 9.0% ± 0.7 L.P.G. 10.5% ± 1.0 DHW Circuit Pressures Max Operating Min Operating Flow Rates (24) l/min DHW Flow @ 30o CRise 10.9 DHW Flow o @ 35 CRise 9.8 Min Working DHW Flow 2 bar 8 0.
Megaflo System Compact GA Baxi Megaflo System Compact GA Output: 12,15,18, 24 and 28kW 390mm 390mm 5mm 5mmMin Min 5mm 5mmMin Min (450mm - 32kW model) 162mm 106mm 175mm Min 175mm Min (300mm Min if if (300mm Min using 80/125mm using 80/125mm flueing system) flueing system) At least 1.
Megaflo System Compact GA Baxi Megaflo System GA Output: 32kW 390mm 390mm 450mm 5mm Min 5mm Min 5mm Min 5mm Min 5mm Min 5mm Min (450mm - 32kW model) (450mm - 32kW model) 170mm 162mm 106mm 106mm 175mm Min 175mm Min 175mm Min (300mm Min (300mm Min if ifif (300mm Min using 80/125mm using 80/125mm using 80/125mm flueing system) flueing system) flueing system) 700mm 700mm (763mm 763mm (763mm - 32kW model) 32kW model) 150mm Min 150mm Min 150mm Min Clearances Above Flue: Left: Right: At least 1.
Megaflo System Compact GA Flue lengths In line bend reduction amount: 135° = 0.5m, 93° = 1.0m. Flue group are also applicable to the Baxi Megaflo System GA 32kW. Horizontal or Vertical Max. permissible Flue Group (diameter) (H/V?) length Flue Group A (60/100) H&V 10m Flue Group G (80/125) H&V 20m Flue Group N (80/80) H&V 15m Horizontal and vertical fluing options Multifit Flue Group A – (60mm/100mm Concentric flue) horizontal and vertical options Part No. 720599401 Part No. 720598701 Part No.
Megaflo System Compact GA Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.5m, 93° = 1.0m. Multifit Flue Group G – (80mm/125mm Flue systems) horizontal and vertical options Part No. 5118580 Horizontal Flue Kit 685mm Part No. 5118588 Part No. 5118584 1m Flue Extension Kit Part No. 5118610 Part No. 5118597 Bend (pair) 135˚ Part No. 5111078 Bend 91.5˚ Flue Support Bracket 125mmØ Vertical Flue Terminal 80/125 (Black) Part No. 246143 Part No. 5122151 Part No.
Megaflo System Compact GA Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.25m, 93° = 0.5m. Multifit Flue Group N – (80mm Twin Flue systems) horizontal and vertical options Part No. 5111087 Flue Extension (pair, includes 2 brackets) Part No. 5111084 Part No. 5111072 Flue Bend (pair) 90˚ Part No. 5120172 Part No. 5111086 Flue Bend (pair) 135˚ Part No.
Megaflo System Compact GA For Plume Displacement Kit permissible flue lengths please see page 13. 500mm Min. IMPORTANT: If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors. The inlet of the PDK MUST be at least 300mm above ground or balcony level or any projection or ledge. A guard must be fitted where the inlet is below 2 metres. Flue options White Black Plume Displacement Kits Ø 60/100mm - Multifit Flue Group A Part No.
Megaflo System Compact GA Technical data (12, 15, 18, 24, 28) Appliance Type C13 C33 Heat Input CH (Net) C43 Max 12 model kW 12 15 model kW 15 18 model kW 18 24 model kW 24 28 model kW 28 Heat Output CH (Condensing) Max 12 model kW 12.7 15 model kW 15.9 18 model kW 19 24 model kW 25.4 28 model kW 29.6 C53 Min 2.1 2.2 2.6 3.5 4.1 Min 2.2 2.3 2.8 3.7 4.3 NATURAL GAS ONLY ! (Natural Gas - G20) Max Gas Rate (After 10 mins) 12 model m3/h 1.27 15 model m3/h 1.59 18 model m3/h 1.90 24 model m3/h 2.
Megaflo System Compact GA Technical data (32) Outercase Dimensions Casing Height Overall Height Inc Flue Casing Width Casing Depth 700mm 860mm 390mm 300*mm *This can be reduced to 290mm by removing the boiler control access flap Weights Packaged Boiler Installation Lift Packaged Boiler Installation Lift NOx Class 5 (12/15/18/24 model) 36.5kg 32.5 kg (28 model) 38.5kg 34.5 kg CO2 N.G. 9.0% ± 0.7 L.P.G. 10.5% ± 1.
Solo HE A Baxi Solo HE A 5mm Min 390mm 5mm Min 200mm Min (300mm Min if using 80/125mm At least 1.5° 600mm 500mm Min For Servicing Purposes 285mm 50mm Min 5mm Min In Operation Clearances Above Flue: Left: Right: 200mm 5mm 5mm Below: Front 50mm* 5mm (in operation) 500mm (for servicing) *This is MINIMUM recommended dimension. Greater clearance will aid installation and maintenance.
Solo HE A Flue lengths Flue Group (diameter) Flue Group B (70/110) Flue Group P (80/80) Flue Group L (70/110) Horizontal or Vertical (H/V?) H&V H&V N/A Max. permissible length 4m + terminal 75m N/A Horizontal and vertical fluing options In line bend reduction amount: 135° = 0.5m, 93° = 1.0m. Multifit Flue Group B – (70mm/110mm Concentric flue) horizontal and vertical options Part No. 243013BAX Horizontal Flue Terminal 0.85m Part No. 241694 Flue Extension 0.5m Part No.
Solo HE A Horizontal and vertical fluing options In line bend reduction amount: 135° = Air 1.3m, Flue gas 2.6m; 93° = Air 4.8m, Flue gas 9.6m Multifit Flue Group P – (80mm Twin Flue systems) horizontal and vertical options Part No. 246137 Part No. 246136 Part No. 246135 Flue Extension (pair) 1m Flue Extension (pair) 0.5m Flue Extension (pair) 0.25m Part No. 5121560 Part No. 243013 BAX Flue Bend (pair) 90° Horizontal Wall Terminal Part No. 242757 Part No. 5121561 Part No. 242757 Part No.
Solo HE A For Plume Displacement Kit permissible flue lengths please see page 13. 500mm Min. IMPORTANT: If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors. The inlet of the PDK MUST be at least 300mm above ground or balcony level or any projection or ledge. A guard must be fitted where the inlet is below 2 metres. Flue options Plume Displacement Kits 70/110mm diameter - Mulitfit Flue Group L Part No.
Solo HE A Technical data Appliance Type C13, C33, C53 Heat Input (Q) (Gross) Gross 12 model kW 15 model kW 18 model kW 24 model kW 30* model kW Appliance Category CAT I 2H Max 13.34 16.88 20.18 24.50 33.76 Min 10.2 10.2 10.2 10.2 10.2 *NOTE: The maxiwmum output of the 30 model is factory set at 22.0kW. This can be altered to 30.18kW Heat Output (Condensing 40° C Mean Water Temp) Max Min 12 model kW 12.81 15 model kW 16.49 10.1 18 model kW 19.27 24 model kW 23.8 10.1 30 model kW 32.61 10.
Solo HE A Electrical Supply 230V~ 50Hz (Appliance must be connected to an earthed supply) External Fuse Rating 3A Water Content litres 2.6 pints 4.6 Static Head max 30 metres (100 ft) min 1 metre (3.25 ft) Gas Connection G1/2” B.S.P. Inlet Pressure at Gas Valve (Natural Gas) Min 18.1 mbar Max 22.5 mbar Power Consumption 80W Internal Fuse Rating (BS 4265) Fuse 3.15 AT (PCB) Electrical Protection IPX2 Low Head 0.
Accessories and controls Accessories and controls Part Number Temperature Only Control Time only Control Time & Temperature Control Baxi room thermostat Baxi electro mechanical 24hr timer kit Baxi plug in digital 24hr timer kit Baxi programmable 24hr wireless sensor 720971401 720645201 720818201 720644901 Baxi Wireless Programmable Room Thermostat 720030501 Baxi wired weather sensor 720103001 Multifit GasSaver Additional items 720971601 Multifit Heatsaver kit Multifit external boiler dischar
Accessories and controls Baxi Duo-tec Combi GA Baxi Neta-tec Combi GA Baxi Megaflo System Compact GA Baxi Solo HE A * 0 For technical enquiries e-mail technical.helpline@bdrthermea.com 45 X8013 - Technical pocket guide DL v14_post proof.
Accessories and controls Accessories and controls The advanced range of Baxi GA boilers deserve state of the art controls and accessories. We’ve introduced sensors that monitor internal and external temperatures so the boiler can adjust its output to perfectly suit the home’s heat requirement, and an external boiler PRV and condensate discharge pump, which removes the need for additional pipework. Fitting Baxi has never been easier.
Accessories and controls Baxi plug-in digital 24 hour timer kit – standard (#720645201) & compact (#720818201) ompatible with Baxi Neta-tec Combi GA and C Baxi Duo-tec Combi GA Plugs into boiler fascia for simple timer option Easy-to-read backlit LCD display The familiarity of a mechanical timer with digital simplicity Time and temperature controls: Baxi Programmable 24 hour wireless sensor (#720644901) ompatible with Baxi Neta-tec Combi GA and C Baxi Duo-tec Combi GA Single channel timer and ro
Accessories and controls Accessories and controls Wired weather sensor (#720103001) onitors outside temperature and optimises M boiler performance for efficiency, economy and comfort Recognised SAP benefit up to 3% No servicing or maintenance Multifit external boiler discharge pump (PRV & condensate) (#720648301) External pump solution Stores and discharges high temperature waste from boiler pressure relief valve avoiding the need for external pipework Manages condensate line waste allowing pump t
Accessories and controls Multifit HeatSaver kit (#720721001) AP benefit up to 7.
Accessories and controls Accessories and controls Condensate trace heating kits Baxi is pleased to present an addition to the Multifit accessory range: the Multifit Condensate Trace Heating Kit. The Multifit Condensate Trace Heating Kit is compatible with all condensing boilers and easy for installers to fit where external condensate pipes are used.
Low zero carbon Low zero carbon overview Baxi Ecogen™ The Baxi Ecogen is a dual energy micro-CHP boiler, delivering highly efficient heating and hot water and generating up to 1kW/h of low cost, low carbon electricity. MCS certified. Baxi Solargen™ The Baxi Solargen is a complete PV kit which uses energy from daylight to produce clean, sustainable electricity. The range includes a number of outputs with both pitched roof & flat roof mountings available.
Baxi Solarflo™ Why use Solar? Savings for customers mean opportunities for installers Real savings can be made over the medium to long term when homeowners switch to renewable energy sources. As the world’s supply of gas diminishes, we must use this resource more efficiently and find other ways of meeting our hot water requirements.
Baxi Solarflo™ Baxi Solarflo™ key features & benefits: n-roof, in-roof and flat roof O portrait or landscape solar collector panel packages available (1, 2 or 3 panels) to enable installation to most roof styles vacuated tube packages also E available (20 or 30 tubes) rovides approximately 55% P of a home’s annual domestic hot water needs The package consists of solar collector panel (s), a hydraulic pump station, controller and all the components required for safeoperation ompatible with Heatrae
Baxi Solarflo™ On-roof Baxi Slate & Tile On-roof System Includes 1, 2 or 3 panels Solar controller Mounting rail and brackets Portrait or landscape options Solar fluid Codes portrait Codes landscape 2 panel 2 panel 720671901 1 panel 720670401 3 panel 720670801 720670601 1 panel 720671701 3 panel 720672101 Baxi Flat Roof A-frame System Includes 1, 2 or 3 panels Solar controller A-frame Portrait or landscape options Solar fluid Codes portrait Codes landscape 2 panel 2 panel 720676701
Baxi Solarflo™ In-roof Baxi Slate In-roof System Includes 1,2 or 3 panels 2.0m2 or 1 or 2 panels 2.5m2 Solar controller Mounting rail and brackets Solar fluid Portrait or landscape* options Slate flashing kit Codes portrait 2.0m2 Codes landscape 2.0m2 Codes portrait 2.5m2 2 panel 720763101 2 panel 720765101 2 panel 720764201 1 panel 720762501 1 panel 720764701 3 panel 720763501 3 panel 720765401 1 panel 720763801 Baxi Tile In-roof System Includes 1,2 or 3 panels 2.0m2 or 1 or 2 panels 2.
Baxi Solarflo™ Evacuated tube Baxi Evacuated Tubes for Slate or Tile Pitched Roof Includes 20 or 30 tubes Solar controller Mounting rail and brackets Solar fluid 30m flexible stainless steel pipe kit Hydraulic Pump Station Expansion vessel Manifold Codes 20 tube* 30 tube 5130214 5130215 * Evacuated tubes can be orientated portrait of landscape to suit application.
Baxi Solarflo™ East/West array kits The East/West array package is perfect for roof orientations which are not south facing. The kit enables collectors to be fitted on either side of the roof structure with one panel facing east and one facing west. East/West array kits enable solar gain around the building throughout the day. The solar controller supplied with the main hydraulic pump station (see Installation Guide on www.baxi.co.uk) already has the facility built in to control an East/West array.
Training Our support for you Our free product training courses are available throughout the UK and are a great way to learn about Baxi boilers So that you’re happy and confident in installing our great products, we provide a range of high quality courses on electrics, diagnostics, controls and every other aspect of installation. Our courses are held at dedicated, fully equipped UK training centres and delivered by trainers with many years’ experience of Baxi products.
heateam Supporting the best, with the best heateam, our award winning customer service division, is our team of 270 Gas Safe registered engineers working across the UK to ensure your customers are happy with their investment in their Baxi boiler. In fact, it’s like having your very own aftersales team. Any problems encountered with a Baxi product within two years of installation will be resolved quickly and efficiently by one of our engineers.
works works – You’ve earned it We want to thank you for your business and help you grow it Running a business of any size isn’t easy, especially in the current economic climate. That’s why we’ve set up works, our great business support scheme. Far more than a loyalty programme, works rewards genuine two-way communication between you and Baxi.
Supporting literature Baxi literature General Baxi GA Range Guide Baxi Pocket Guide Sales Order Code 402050 350621 Baxi Duo-tec Combi GA Sales Order Code Installation Instructions 7206334 User instructions Homeowner sales brochure Baxi Neta-tec Combi GA User instructions Installation Instructions Homeowner sales brochure Baxi Megaflo System Compact GA User instructions Installation Instructions Homeowner sales brochure Baxi Solo HE A User instructions Installation Instructions Homeowner sa
Conversion tables Metric and Imperial measures Imperial to Metric units 1 inch = 25.4 mm = 2.54 cm 1 foot = 304.8 mm = 0.3048 m 1 yard = 914.4 mm = 0.9144 m 1 mile = 1609 m = 1.609 km 1 square inch = 645.2 mm = 6.452 cm2 1 cubic inch = 16387 mm3 = 0.016 39 dm3 1 cubic yard = 0.764555 m3 1 ton = 1016 kg 0.1 inches water gauge = 0.25 mbar 1.0 inch water gauge = 2.5 mbar 1 atmosphere = 1.01325 bar 1 British thermal unit (Btu) = 1055 J 1 therm = 105.5 MJ 1000 Btu/h = 0.
Conversion tables Metric to Imperial units 1 millimetre = 0.03937 in 1 metre = 39.37 in = 3.281 ft 1 kilometre = 0.6214 mile = 1094 yd = 1.094 yd 1 square millimetre = 0.001550 in2 1 square metre = 1.196 yd2 = 0.047 hectare 1 cubic millimetre = 0.000061 in3 1 cubic decimetre = 61.02 in3 = 0.035 31 ft3 1 cubic metre = 35.31 ft3 = 1.308 yd3 = 220.0 gal 1 litre = 1.760 pint = 0.2200 gal = 0.035 ft3 1 gram = 0.03527 oz = 15.43 grains 1 kilogram = 2.
Gas rating chart Gas rating chart natural gas Gas rating chart for domestic gas meters (up to 6 m3/ hr) which measures gas in m3 Average CV = 38.76MJ/m3 -1040btu/ft3 m3 2 min kW (gross) 0.004 1.29 0.008 2.58 0.002 0.006 0.010 0.012 0.014 0.016 kW (net) 1.94 1.75 0.056 1.16 2.33 3.23 2.91 4.52 4.07 3.88 5.17 3.49 4.66 7.11 6.40 8.40 7.57 6.46 0.024 7.75 0.028 9.04 9.69 5.24 5.82 6.98 8.15 8.73 0.032 10.34 0.036 11.63 10.48 12.92 11.64 0.034 0.038 0.040 0.042 10.98 12.
Gas rating chart m3 2 min 0.102 kW (gross) kW (net) m3 2 min kW (gross) 0.154 49.74 32.95 29.68 0.152 0.106 34.24 30.85 0.156 0.110 35.53 0.104 0.108 0.112 0.114 0.116 0.118 33.59 34.88 30.26 31.43 32.01 36.18 32.59 37.47 33.75 36.82 38.11 33.17 34.34 0.120 38.76 0.124 40.05 36.08 41.34 37.25 0.122 0.126 0.128 0.130 39.41 40.70 41.99 0.132 42.64 0.136 43.93 0.134 0.138 0.140 0.142 43.28 36.66 37.83 38.41 38.99 39.57 40.16 45.87 41.32 45.22 46.51 0.148 47.
Gas rating chart Gas rating chart for domestic gas meters (up to 212 ft3/ hr) which measures gas in ft3 Average CV = 38.76MJ/m3 -1040btu/ft3 Sec 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 52 54 56 58 60 62 64 66 kW (gross) 64.57 60.98 57.77 54.89 52.27 49.90 47.73 45.74 43.91 42.22 40.66 39.20 37.85 36.59 35.41 34.30 33.23 32.29 31.36 30.49 29.67 28.89 28.15 27.44 26.77 26.14 25.53 24.95 24.39 23.86 23.36 22.87 22.40 21.95 21.11 20.33 19.60 18.9.
Useful contacts Useful contacts Useful contacts Head Office: Baxi, Brooks House, Coventry Road, Warwick, CV34 4LL Tel: 0844 871 1525 (option 6) Email: info@baxi.co.uk General webiste: www.baxi.co.uk Specification website: www.baxiknowhow.co.uk aftersales service Tel: 0844 871 1525 (option 1) Fax: 01926 410006 Email: info@baxi.co.uk Technical Tel: 0844 871 1525 (option 2) Fax: 01926 410006 Email: technical.helpline@bdrthermea.com Literature Tel: 0844 871 1525 (option 3) Email: info@baxi.co.
Useful contacts Useful contacts Energy Saving Trust Tel: 020 7222 0101 Website: www.energysavingtrust.org.uk Gas Safe Register Tel: 0800 408 5577 Email: enquiries@gassaferegister.co.uk Web: www.gassaferegister.co.uk Chartered Institute of Plumbing & Heating Engineering Tel: : 01708 472791 Email: info@ciphe.org.uk www.ciphe.org.uk Association of Plumbing and Heating Contractors Tel: 0121 711 5030 Email: info@aphc.co.uk Web: www.aphc.co.
Notes Useful contacts Notes For technical enquiries e-mail technical.helpline@bdrthermea.com 69 X8013 - Technical pocket guide DL v14_post proof.
Notes Notes 70 X8013 - Technical pocket guide DL v14_post proof.