16
Photovoltaic Wire
ServiceSolar
®
(for use with Solar Panels)
VW-1, USE-2 or RHH or RHW-2
1,000/2,000 Volt Copper
Standards:
ASTM B3, B8 and B787
UL 44, UL 854, UL 4703,
C(UL) RPVU90 1kV/RPV90 2kV
Direct Burial Rated
Flame Rated: VW-1/FT1
Federal Spec. A-A-59544
ICEA S-95-658/NEMA WC-70
For CT use 1/0 AWG and larger
Sunlight Resistant
Gasoline and Oil Resistant II
-40°C rated
Suitable for use in 105°C Dry System
RoHS Compliant
Description:
Single copper conductor, stranded, insulated with moisture and
heat resistant cross-linked polyethylene. Rated 2KV to meet the
challenging requirements of transformerless inverters on photovoltaic
(solar) panel installations. Temperature rating is 90°C in wet and dry
applications. Available in colors.
Applications:
Photovoltaic wire (1,000/2,000 Volt) for use as interconnection wiring
on solar panels in grounded or ungrounded systems as defined in
applicable parts of the National Electrical Code (NEC) NFPA 70,
such as article 690.31(A).
Also suitable for use in low leakage circuits
requiring a dielectric constant of 3.5 or less (Hospital Grade).
Part
Number
Size
AWG
or
MCM
Strand
(no.)
Insulation
Thickness
(mils)
Nominal
Diameter
Overall
(inch)
Approx. Net
Weight
(lbs./mft)
Ampacity*
90°C
Wet/Dry
XLPE PV / 1KV / 2KV RHH / RHW-2
PV2K14VW
14 7 75 .223 33 35 †
PV2K14VW-C
14 19 75 .223 33 35 †
PV2K12VW
12 7 75 .242 43 40 †
PV2K12VW -C
12 19 75 .242 43 40 †
PV2K10VW
10 7 75 .266 58 55 †
PV2K10VW-C
10 19 75 .266 58 55 †
PV2K8VW
8 7 85 .316 86 80
PV2K8VW-C
8 19 85 .316 86 80
PV2K6VW
6 7 85 .354 122 105
PV2K4VW
4 7 85 .402 177 140
PV2K3VW
3 7 85 .430 215 165
PV2K2VW
2 7 85 .432 262 190
PV2K1VW
1 19 105 .531 338 220
PV2K1/0VW
1/0 19 105 .570 413 260
PV2K2/0VW
2/0 19 105 .614 506 300
PV2K3/0VW
3/0 19 105 .664 623 350
PV2K4/0VW
4/0 19 105 .720 768 405
PV2K250VW
250 37 120 .815 920 455
PV2K300VW
300 37 120 .869 1,086 500
PV2K350VW
350 37 120 .921 1,260 570
PV2K400VW
400 37 120 .968 1,416 615
PV2K500VW
500 37 120 1.053 1,752 700
PV2K600VW
600 61 135 1.163 2,099 780
PV2K750VW
750 61 135 1.268 2,587 885
*Based on ambient temperature of 30°C per NEC-Table 310-17
The overcurrent protection for items marked with an obelisk (†) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC 310-17 footnote.