Cut Sheet

Conductor
Size+ (AWG)
Solid or
Stranded*
Grounding
Conductor
Size (AWG)
Outside Diameter
Over Armor
(inches)
Outside Diameter
Over Jacket
(inches)
Total Weight
(Ibs/1000 ft.)
Ampacities‡ (Amps) Standard Package
60°C 75°C 90°C Coil (feet) Reel (feet)
14/2 Solid 14 sol 0.439 0.539 122 15 15 15 250 1000
14/3 Solid 14 sol 0.464 0.565 142 15 15 15 250 1000
14/4 Solid 14 sol 0.494 0.594 162 15 15 15 250 1000
12/2 Solid 12 sol 0.475 0.575 152 20 20 20 250 1000
12/3 Solid 12 sol 0.505 0.605 180 20 20 20 250 1000
12/4 Solid 12 sol 0.539 0.639 209 20 20 20 250 1000
10/2 Solid 10 sol 0.542 0.642 204 30 30 30 250 1000
10/3 Solid 10 sol 0.580 0.680 247 30 30 30 250 1000
10/4 Solid 10 sol 0.623 0.723 291 30 30 30 250 1000
12/2 19 12-19 0.564 0.664 178 20 20 20 ---- 1000
12/3 19 12-19 0.602 0.702 217 20 20 20 ---- 1000
12/4 19 12-19 0.680 0.780 272 20 20 20 ---- 1000
10/2 19 10-19 0.653 0.753 245 30 30 30 ---- 1000
10/3 19 10-19 0.701 0.801 344 30 30 30 ---- 1000
10/4 19 10-19 0.799 0.899 436 30 30 30 250 1000
8/2 19 10-19 0.678 0.778 302 40 50 55 200 500
8/3 19 10-19 0.732 0.832 379 40 50 55 200 500
8/4 19 10-19 0.793 0.893 455 40 50 55 200 500
6/2 19 8-19 0.756 0.856 411 55 65 75 125 500
6/3 19 8-19 0.819 0.919 521 55 65 75 125 500
6/4 19 8-19 0.890 0.990 631 55 65 75 100 500
4/3 19 8-19 0.986 1.086 731 70 85 95 100 500
4/4 19 8-19 1.077 1.177 903 70 85 95 100 500
2/3 19 6-19 1.130 1.231 1042 95 115 130 100 500
2/4 19 6-19 1.239 1.339 1302 95 115 130 100 500
Note: Ampacities are based on Table 310.16 of the NEC, 2008 Edition.
‡Allowable ampacities shown are for general use as specified by the National Electrical Code, 2008 Edition, Section 310.15.
If the equipment is marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C).
60°C - When terminated to equipment for circuits rated 100 amperes or less or marked for size 14 through 1 AWG conductors.
75°C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG.
90°C - For ampacity derating purposes.
Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor.
*Circuit sizes 12 AWG and 10 AWG also available as stranded conductors.
+ Available in sizes up to 750 kcmil.
FEATURES
Reduces installation costs up to 50% over pipe and wire.
Lightweight aluminum armor--as much as 45% lighter than steel MC Cable.
UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117,
W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065,
C-AJ-4066, F-C-3038.