Cut Sheet

Color
CodeChart
No. of
Conductors
Color
T
racer
No. of
Conductors
Color
T
racer
1
B
lack
--
12
B
lack
White
2
White
--
13
Red
White
3
Red
--
14
Green
White
4
Green
--
15
Blue
White
5
Orange
--
16
Black
Red
6
B
lue
--
17
W
hite
Red
7
W
hite
Black
18
O
range
Red
8
R
ed
Black
19
B
lue
Red
9
Green
Black
20
Red
Green
10
Orange
Black
21
Orange
Green
11
Blue
Black
Little Rock
1-800-945-5542
Baton Rouge
1-888-754-5707
Houston
1-888-388-6280 http://www.prioritywire.com
MU L
TI-CONDUCTOR
TYPE
SOOW
90°
600
V
olt
UL/CSA
Portable
Cord
Application:
F
or
use
with
control ci rcuit s,
too l s,
he a vy
indust rial,
processing and
construction equipment.
Specifications:
Conductors:
14 through 10
A WG
fully
annealed
stranded bare copper per
ASTM
B -174
Insulation:
Premium
grade col or coded
90°C
CPE,
refer to
color
code
chart.
Jacket:
T
emp er a
ture
R a
tin g -4C to
+
90°C
CPE
Extra
flexible stranding
Resists
flame,
ozone,
oils,
solvents,
and abrasion
90°C
ra ted c onducts and
jacket
UL
Listed and
CSA
Certifi ed
for
indoor and outdoor
use
UL
Flexible Cord
Subject
62
and
CSA
Flexible Cor d
C -2 2.2 -4 9
OSHA
Acceptable and
MSHA
A
pproved,
JC
580
Nominal Insulation
Thickness
Nominal
Overall
Diameter
No.
of
Conductors
A WG
Conductor
Strand
Inches
mm
Inches
mm
Current
Amps
**
W
eight
LBS/M
5
14
41/30
.045
1.14
.650
16 .51
12
275
6
14
41/30
.045
1.14
.710
18.03
12
315
7
14
41/30
.045
1.14
.710
18.03
10.5
345
8
14
41/30
.045
1.14
.760
19.30
10.5
385
9
14
41/30
.045
1.14
.830
21.08
10.5
410
10
14
41/30
.045
1.14
.830
21.08
7.5
430
12
14
41/30
.045
1.14
.870
22.10
7.5
485
14
14
41/30
.045
1.14
1.000
25.40
7.5
590
16
14
41/30
.045
1.14
1.030
26.16
7.5
665
18
14
41/30
.045
1.14
1.100
27.94
7.5
710
20
14
41/30
.045
1.14
1.155
29.34
7.5
780
24
14
41/30
.045
1.14
1.260
32.00
6.7
985
28
14
41/30
.045
1.14
1.330
33.78
6.7
1080
30
14
41/30
.045
1.14
1.340
34.04
6.7
1130
37
14
41/30
.045
1.14
1.480
37.54
6
1330
5
12
65/30
.045
1.14
.710
18.03
16
330
6
12
65/30
.045
1.14
.740
18.80
16
360
7
12
65/30
.045
1.14
.770
19.56
14
415
8
12
65/30
.045
1.14
.825
20.96
14
470
9
12
65/30
.045
1.14
.900
22.86
14
515
10
12
65/30
.045
1.14
1.000
25.40
14
580
12
12
65/30
.045
1.14
1.010
25.65
10
650
14
12
65/30
.045
1.14
1.080
27.43
10
740
16
12
65/30
.045
1.14
1.135
28.83
10
835
18
12
65/30
.045
1.14
1.150
29.97
10
910
20
12
65/30
.045
1.14
1.170
30.48
10
990
24
12
65/30
.045
1.14
1.400
35.56
9
1240
26
12
65/30
.045
1.14
1.400
35.56
9
1270
27
12
65/30
.045
1.14
1.485
37.72
9
1310
28
12
65/30
.045
1.14
1.500
38.10
9
1345
30
12
65/30
.045
1.14
1.500
38.10
9
1415
36
12
65/30
.045
1.14
1.653
41.99
8
1670
40
12
65/30
.045
1.14
1.690
42.93
8
1830
44
12
65/30
.045
1.14
1.885
47.88
7
2000
50
12
65/30
.045
1.14
1.970
50.04
7
2300
5
10
104/30
.045
1.14
.770
19.56
20
465
6
10
104/30
.045
1.14
.875
22.23
20
500
8
10
104/30
.045
1.14
.940
23.88
17.5
625
10
10
104/30
.045
1.14
1.025
26.04
17.5
765
12
10
104/30
.045
1.14
1.140
28.96
12.5
865
16
10
104/30
.045
1.14
1.230
31.24
12.5
1150
20
10
104/30
.045
1.14
1.260
32.00
12.5
1445
**
V
alues sh o
wn
are
for current
car rying conductors.
A
groundin g conducto r
,
or
one
which
carries only the unbalanced
current from
other conductors,
is
NOT
counted
in
determining
current
car rying ca pacit y
.
1-800-945-5542
©
Priority
Wir
e &
Cable,
Inc. Little Rock,
AR,
2003 PWC02/2003

Summary of content (1 pages)