Cut Sheet
Applications: Wiring of thermostat controls, heating and air conditioning equipment, doorbells,
as well as other low voltage applications. Sunlight resistant except CL2P.
Features: Sequential footage markings on spools. Braided ripcord.
THERMOSTAT CABLE 60° C - CL2
Thermostat Cables
For Spec Sheets go to http://www.genesiscable.com/LitCenter.asp
Code Restrictions:
OK for use with all power-limited circuits except those in risers and plenums.
Construction: Copper conductors, polypropylene insulation, polyvinyl-chloride jacket.
Code Restrictions: OK for use with all Power-Limited Circuits.
Construction: Copper Conductors, Low Smoke PVC, Low Smoke PVC Jacket.
AWG #/COND. PACKAGING SOL NOM. O.D. NOM. CAP. PF/FT LISTINGS AVG. WT. PER MFT PART#
20 2 4 x 500 S or 1 x 500 SB SOL .118 17 CL2 11 4701
20 3 4 x 500 S or 1 x 500 SB SOL .124 17 CL2 14 4702
20 4 4 x 250 S or 1 x 250 SB SOL .136
17 CL2 18 4703
20 5 4 x 250 S or 1 x 250 SB SOL .148 17 CL2 20 4704
20 6 4 x 250 S or 1 x 250 SB SOL .161 17 CL2 24 4705
20 7 4 x 250 S or 1 x 250 SB SOL .161 17 CL2 27 4706
20 8 4 x 250 S or 1 x 250 SB SOL .174
17 CL2 31 4707
20 9 4 x 250 S or 1 x 250 SB SOL .188 17 CL2 35 4708•
20 10 4 x 250 S or 1 x 250 SB SOL .204 17 CL2 39 4709•
18 2 4 x 500 S or 1 x 500 SB SOL .136 19 CL2 16 4710
18 3 4 x 500 S or 1 x 500 SB SOL .144
19 CL2 21 4711
18 4 4 x 250 S or 1 x 250 SB SOL .157 19 CL2 26 4712
18 5 4 x 250 S or 1 x 250 SB SOL .172 19 CL2 32 4713
18 6 4 x 250 S or 1 x 250 SB SOL .188
19 CL2 38 4714
18 7 4 x 250 S or 1 x 250 SB SOL .188 19 CL2 44 4715
18 8 4 x 250 S or 1 x 250 SB SOL .204 19 CL2 50 4716
18 9 4 x 250 S or 1 x 250 SB SOL .220 19 CL2 55 4717
18 10 4 x 250 S or 1 x 250 SB SOL .240
19 CL2 61 4718
18 12 1 x 250 S or 1 x 250 SB SOL .248 19 CL2 74 4719
• Consult factory for availability. S=Spools SB=Speedbags MFT=1000 Feet
AWG #/COND. PACKAGING SOL NOM. O.D. NOM. CAP. PF/FT LISTINGS AVG. WT. PER MFT PART#
18 2 4 x 500
S SOL .136 28 CMP, CL2P, C(UL) FT6 17 4760
18 3 4 x 500 S SOL .144 28 CMP, CL2P, C(UL) FT6 23 4761
18 4 4 x 250 S SOL .157 28 CMP, CL2P, C(UL) FT6 29 4762
18 5 4 x 250 S SOL .172 28 CMP, CL2P, C(UL) FT6 35 4763
18 6 4 x 250
S SOL .188 28 CMP, CL2P, C(UL) FT6 42 4764
18 7 4 x 250
S SOL .188 28 CMP, CL2P, C(UL) FT6 47 4765•
18 8 4 x 250 S SOL .204 28 CMP, CL2P, C(UL) FT6 54 4766
18 9 4 x 250 S SOL .220 28 CMP, CL2P, C(UL) FT6 60 4767•
18 10 4 x 250 S SOL .240 28 CMP, CL2P, C(UL) FT6 67 4768
18 12 1 x 250 S SOL .248 28 CMP, CL2P, C(UL) FT6 79 4769•
•
Consult factory for availability. S=Spools MFT=1000 Feet
THERMOSTAT CABLE PLENUM RATED—CL2P