CP
Thin Wall Conduit Fittings
(For EMT Conduit)
ɀ Compression Type Fittings
ɀ Set Screw Type Fittings
ɀ Combination Couplings
ɀ Straight Connectors
ɀ Couplings
COMPRESSION TYPE FITTINGS – RAINTIGHT
CONNECTORS
The Cooper Crouse-Hinds Raintight EMT connectors are used to join
EMT conduit to a box or enclosure in Raintight environments. The
design prevents water seepage into conduit, box or enclosure.
Features and Benefits
ɀ All steel construction with zinc electroplate finish provides for
durable corrosion resistance
ɀ Flat surface on Gland nut provides smooth, flat surface for easy
wrenching
ɀ Distinct black gland nut provides quick raintight identification
ɀ Integral gasketed compression ring secures and seals for reliable
installation
ɀ Interior shoulder conduit stop provides positive seating of conduit
inside the body
ɀ Gasket on male threads of box connector seals installation for
raintight connection between the box and the connector
ɀ Available in insulated and non-insulated versions to meet any
customer preference
ɀ Angled teeth on locknut for secure bite into enclosure
ɀ Extruded locknut with shoulder provides more threads for more
secure installation
ɀ Concrete tight
ɀ Standard material: Steel
ɀ Standard finish: Zinc plated
Certifications and Compliances
ɀ UL Listed
ɀ cUL Listed
Concrete Tight
Straight Connectors – Insulated – Raintight
UL File No. E-22132
Cat. # Size
Unit
Quantity
Standard
Package
Weight
Lbs. Per
100
1650RT
1
⁄2⍯ 50 250 11
1651RT
3
⁄4⍯ 25 125 17
1652RT 1⍯ 25 100 23
1653RT 1
1
⁄4⍯ 10 50 41
1654RT 1
1
⁄2⍯ 10 50 50
1655RT 2⍯ 52567
1656RT 2
1
⁄2⍯ 2 10 177
1657RT 3⍯ 1 5 234
Straight Connectors – Non-Insulated – Raintight
UL File No. E-22132
Cat. # Size
Unit
Quantity
Standard
Package
Weight
Lbs. Per
100
650RT
1
⁄2⍯ 50 250 11
651RT
3
⁄4⍯ 25 125 17
652RT 1⍯ 25 100 23
653RT 1
1
⁄4⍯ 10 50 41
654RT 1
1
⁄2⍯ 10 50 50
655RT 2⍯ 52567
656RT 2
1
⁄2⍯ 2 10 177
657RT 3⍯ 1 5 234
Couplings – Raintight
UL File No. E-22132
Cat. # Size
Unit
Quantity
Standard
Package
Weight
Lbs. Per
100
660RT
1
⁄2⍯ 50 250 14
661RT
3
⁄4⍯ 25 125 21
662RT 1⍯ 25 100 28
663RT 1
1
⁄4⍯ 10 50 49
664RT 1
1
⁄2⍯ 10 50 60
665RT 2⍯ 52579
666RT 2
1
⁄2⍯ 2 10 187
667RT 3⍯ 1 5 245
COMPRESSION TYPE FITTINGS – STEEL
New Space-Saver EMT Connector - Compression
UL File No. E-22132
Features:
ɀ Used to join EMT conduit to a box or
enclosure
ɀ Designed with the male threads on the
locknut, the Space-Saver takes up virtually
no room inside the box and the smooth pulling surface eliminates the
need for a bushing or insulated throat
ɀ Angled teeth on locknut bite into enclosure, preventing loosening
from vibration
ɀ Knurled wrenching surface for easy tightening
ɀ Zinc electroplated for corrosion resistance
ɀ Concrete tight when taped
Certifications and Compliances:
ɀ UL Listed
ɀ cUL Listed
Cat. # Size
Unit
Quantity
Standard
Package
Weight
Lbs. Per
100
SSC50
1
⁄2⍯ 50 250 8
SSC75
3
⁄4⍯ 25 100 12
SSC100 1⍯ 25 100 12
COMPRESSION TYPE FITTINGS – STEEL
Application:
Thinwall conduit fittings are used:
ɀ to join EMT to a box or enclosure
ɀ to couple two ends of EMT conduit
Features: Compression Type
ɀ Unique raised bump design affords fast, positive locking of
compression nuts
ɀ Male Hub Threads - NPSM
ɀ Steel Locknuts
ɀ Heavy Steel Walls
ɀ Standard Material: Steel
ɀ Standard Finish: Zinc Plated
Concrete Tight
Straight Connectors – Insulated
UL File No. E-22132
Cat. # Size
Unit
Quantity
Standard
Package
Weight
Lbs. Per
100
1650
1
⁄2⍯ 50 250 11
1651
3
⁄4⍯ 25 125 16
1652 1⍯ 25 100 25
1653 1
1
⁄4⍯ 10 50 43
1654 1
1
⁄2⍯ 10 50 54
1655 2⍯ 52576
1656 2
1
⁄2⍯ 2 10 190
1657 3⍯ 1 5 300
1658 3
1
⁄2⍯ 1 5 330
1659 4⍯ 1 5 360
Straight Connectors – Non-Insulated
UL File No. E-22132
Cat. # Size
Unit
Quantity
Standard
Package
Weight
Lbs. Per
100
650S
1
⁄2⍯ 50 250 9
651S
3
⁄4⍯ 25 125 16
652 1⍯ 25 100 25
653 1
1
⁄4⍯ 10 50 43
654 1
1
⁄2⍯ 10 50 54
655 2⍯ 52576
656 2
1
⁄2⍯ 2 10 190
657 3⍯ 1 5 300
658 3
1
⁄2⍯ 1 5 280
659 4⍯ 1 5 360
ɀCP
Thinwall
Fittings