Cut Sheet
II.
CONSTRUCTION (Continued):
SIZE
(AWG
or
KCMIL)
STRANDING
CONDUCTOR
DIAMETER
(INCHES)
1/0 19/.0745” .365
2/0 19/.0837” .411
4/0 19/.1055” .517
350 37/.0973” .667
500 37/.1162” .797
750 61/.1109” .978
A. CONDUCTORS:
Class B stranded, tin-
coated copper conforming to ASTM B
Underwriters’ Laboratories requirements. An opaque Mylar tape shall
applied over the conductor to facilitate stripping. Bare copper is available
upon request.
B. INSULATION:
90°C / 105°C rated limited smoke, non
Underwriters’ Laboratories Standard 44, Subjects 509 and 758, and CSA
No. 210.2 M90. In addition, TelcoHyde
of Telcordia Specification GR
Index of 35%.
C. SEPARATOR:
On sizes 6 AWG and larger, a 1 mil clear Mylar tape shall be applied
insulation.
D. COVERING:
On all sizes, a natural cotton braid conforming to UL Standard 44 requirements
is applied overall. A section of completed cable has a Limiting Oxygen Index
of 35%.
E. FINISH:
A moisture resistant, fire retardant saturan
to the braid.
CONSTRUCTION (Continued):
CONDUCTOR
DIAMETER
(INCHES)
INSUL.
MIN.
AVG.
WALL
(MILS)
NOMINAL
INSUL.
DIAM.
(INCHES)
NOMINAL
BRAID
DIAM.
(INCHES)
MAX
RES. @
20°C
(OHMS/M’)
80 .530 .580
0.106
.575 .630
0.084
.680 .735
0.052
95 .860 .915
0.032
.990 1.045
0.022
110 1.200 1.260
0.0148
coated copper conforming to ASTM B
-
33 and
Underwriters’ Laboratories requirements. An opaque Mylar tape shall
applied over the conductor to facilitate stripping. Bare copper is available
90°C / 105°C rated limited smoke, non
-halogen TelcoHyde
®
5221 conforming to
Underwriters’ Laboratories Standard 44, Subjects 509 and 758, and CSA
No. 210.2 M90. In addition, TelcoHyde
®
5221 complies with the requirements
of Telcordia Specification GR
-347-
CORE. The insulation has a Limiting Oxygen
On sizes 6 AWG and larger, a 1 mil clear Mylar tape shall be applied
On all sizes, a natural cotton braid conforming to UL Standard 44 requirements
is applied overall. A section of completed cable has a Limiting Oxygen Index
A moisture resistant, fire retardant saturan
t and a colored finisher are applied
MAX
D.C.
RES. @
20°C
(OHMS/M’)
AMPACITY
PER NEC
TABLE
310.16
75°C 90°C
0.106
150 170
0.084
175 195
0.052
230 260
0.032
310 350
0.022
380 430
0.0148
475 535
33 and
Underwriters’ Laboratories requirements. An opaque Mylar tape shall
be
applied over the conductor to facilitate stripping. Bare copper is available
5221 conforming to
Underwriters’ Laboratories Standard 44, Subjects 509 and 758, and CSA
C22.2
5221 complies with the requirements
CORE. The insulation has a Limiting Oxygen
On sizes 6 AWG and larger, a 1 mil clear Mylar tape shall be applied
over the
On all sizes, a natural cotton braid conforming to UL Standard 44 requirements
is applied overall. A section of completed cable has a Limiting Oxygen Index
t and a colored finisher are applied