Instructions
Instruction Sheet
Subject: BIC LMS Valve Replacement
SCOPE: MULTIPLEX BIC UNITS MA-8-2, MA-8-2BF, MA-8-2AF
1 of 3
Document Number: MPX-i-078 October 07, 2022
MULTIPLEX
645 PARK EAST BLVD SUITE 5, NEW ALBANY, IN 47150
844724CARE
WWW.MULTIPLEXBEVERAGE.COM
Refreshing the Experience
TOOLS REQUIRED
• Safety Gloves (cut resistant)
• Oetiker Pliers (PN 00681815)
• Needle Nose Pliers
• Screw Drivers, Phillips & Flat Head
• 3/8” or ¼” Drive Socket Set (3/8” and 5/16”)
• Cleaning Manifold & Cleaning Buckets (store supplied)
PARTS REQUIRED
• Food Grade Lubricant
• Replacement parts listed below:
QTY DESCRIPTION PART NUMBER
9 Valve, Dispense Outlet, LMS 1706172
9 15.7 Oetiker Clamp 15.7-706R
NOTE: There are two different User Interface (UI) screens
that are used on Blend-in-Cup (BIC) units. See below for
reference names.
Common Controller
Glass Screen
MR7
Plastic Overlay
DISPENSE MOUNTING PLATE
FRONT OF UNIT
BACK OF UNIT
WATER
18
45
7 2
36
INSTRUCTION
1. Verify operation of unit with manager. Make notes and
take pictures of any issues.
2. Move all product/bins from lower refrigerated cabinet
to store’s walk-in cooler.
3. Rinse and empty product lines by running product
pumps. Use warm water to make lines more pliable.
A. Place cup in dispense area.
B. Fill cleaning bucket with warm water.
C. Connect cleaning manifold to product pumps and
place other end of manifold in bucket of warm water.
D. Use touchscreen to operate solenoids
FOR MR7
Press the BACK arrow to return to easyToUCH screen
Press MANAGER Menu. Press A then GREEN check
Press DOWN arrow then press SERVICE
Press A then press GREEN check
Press OUTPUTS
Toggle each flavor solenoid ON until line runs clear
then toggle OFF. Repeat for each of the eight (8)
solenoids.
FOR COMMON CONTROLLER
From easyToUCH screen press SERVICE
Press A then GREEN check
Press OUTPUTS
Toggle each flavor solenoid ON until line runs clear
then toggle OFF. Repeat for each of the eight (8)
solenoids.