Instructions
3 of 3
Document Number: MPX-i-078 October 07, 2022
Subject: BIC LMS Valve Replacement
17. Reposition the dispensing mounting plate to the top of
the dispensing area and secure with the four (4) outer
screws.
18. Reverse actions in Step 6 pulling the tubing downwards
within the refrigerated cabinet and pushing the tubing
upwards in the dispensing area towards the inside of
the tubing chase.
19. Verify cabinet temperature is 39°F (4°C) or below.
FOR MR7
From easyToUCH screen press the RECIPE BOOK
From drink making screen the cabinet temperature
will display in the top LEFT corner
FOR COMMON CONTROLLER
From easyToUCH screen temperature will display in
the top LEFT corner
20. After cabinet temperature reaches 39°F (4°C) or below
reinstall product bags and bins in correct slots.
21. Prime product lines. Only prime lines that have
product bags installed.
A. Put a cup under the dispense area.
B. Use touchscreen to operate solenoids. See STEP 3
D on page 1.
C. Empty cup in dispense area as needed. Do NOT
pour down the unit drains.
CONFIRM OPERATION
22. With the manager present make sample drinks of each size.
23. Confirm operation of all functions.