Owner manual

DCA180SSI/DCA180SSIU 60 HZ GEN/ • OPERATION AND PARTS MANUAL — REV. #1 (08/02/10) — PAGE 31
INSPECTION/SETUP
Refueling Procedure:
1. Level Tanks — Make sure fuel cells are level with the
ground. Failure to do so will cause fuel to spill from the
tank before reaching full capacity (Figure 30).
Figure 30. Only Fill on Level Ground
2. Open cabinet doors on the “right side” of the generator
(from generator control panel position). Remove fuel
cap and fill tank (Figure 31).
WARNING
Diesel fuel and its vapors are dangerous
to your health and the surrounding
environment. Avoid skin contact and/or
inhaling fumes.
CAUTION
ALWAYS place trailer on firm level ground before
refueling to prevent spilling and maximize the amount
of fuel that can be pumped into the tank.
NOTICE
ONLY use #2 diesel fuel when refueling.
Figure 31. Fueling the Generator
3. NEVER overfill fuel tank It is important to read the
fuel gauge when filling trailer fuel tank. DO NOT wait
for fuel to rise in filler neck (Figure 32).
Figure 32. Full Fuel Tank
Figure 33. Fuel Expansion
COOLANT (ANTIFREEZE/SUMMER COOLANT/
WATER)
ISUZU recommends ISUZU antifreeze/summer coolant for
use in their engines, which can be purchased in concentrate
(and mixed with 50% demineralized water) or pre-diluted. See
the ISUZU Engine Owner’s Manual for further details.
CAUTION
DO NOT OVERFILL fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 33).
WARNING
If adding coolant/antifreeze mix to the
radiator, DO NOT remove the radiator cap
until the unit has completely cooled. The
possibility of hot! coolant exists which can
cause severe burns.