OPERATION AND PARTS MANUAL WHISPERWATT™ SERIES MODEL DCA20SPXU2 DIGITAL CONTROLLER 60HZ GENERATOR (ISUZU BV-4LE2 DIESEL ENGINE) PARTS LIST NO. M1873300004 Revision #1 (03/25/11) To find the latest revision of this publication, visit our website at: www.mqpower.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
PROPOSITION 65 WARNING Diesel engine exhaust and some of PAGE 2 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
REPORTING SAFETY DEFECTS If you believe that your vehicle has a defect that could cause a crash or could cause injury or death, you should immediately inform the National Highway Traffic Safety Administration (NHTSA) in addition to notifying Multiquip at 1-800-421-1244. If NHTSA receives similar complaints, it may open an investigation, and if it finds that a safety defect exists in a group of vehicles, it may order a recall and remedy campaign.
TABLE OF CONTENTS DCA20SPXU2 60 Hz Generator With Digital Controller Proposition 65 Warning ........................................... 2 Reporting Safety Defects......................................... 3 Table Of Contents .................................................... 4 Parts Ordering Procedures ...................................... 5 Safety Information .............................................. 6-11 Specifications ........................................................ 12 Dimensions .........
www.multiquip.com PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Order via Internet (Dealers Only): Best Deal! Effective: January 1st, 2006 If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip. com. Order parts on-line using Multiquip’s SmartEquip website! ■ View Parts Diagrams ■ Order Parts ■ Print Specification Information To obtain an MQ Account, contact your District Sales Manager for more information.
SAFETY INFORMATION Do not operate or service the equipment before reading the entire manual. Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the safety messages and operating instructions could result in injury to yourself and others. Potential hazards associated with the operation of this equipment will be referenced with hazard symbols which may appear throughout this manual in conjunction with safety messages.
SAFETY INFORMATION GENERAL SAFETY CAUTION NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations. NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication. NEVER operate this equipment under the influence of drugs or alcohol.
SAFETY INFORMATION ENGINE SAFETY DANGER The engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled. The engine of this equipment requires an adequate free flow of cooling air. NEVER operate this equipment in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause injury to people and property and serious damage to the equipment or engine.
SAFETY INFORMATION FUEL SAFETY DANGER DO NOT start the engine near spilled fuel or combustible fluids. Diesel fuel is extremely flammable and its vapors can cause an explosion if ignited. Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.” ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains, etc.
SAFETY INFORMATION ELECTRICAL SAFETY DANGER DO NOT touch output terminals during operation. Contact with output terminals during operation can cause electrocution, electrical shock or burn. The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn generator and all circuit breakers OFF before performing maintenance on the generator or making contact with output terminals.
SAFETY INFORMATION BATTERY SAFETY DANGER DO NOT drop the battery. There is a possibility that the battery will explode. DO NOT expose the battery to open flames, sparks, cigarettes, etc. The battery contains combustible gases and liquids. If these gases and liquids come into contact with a flame or spark, an explosion could occur. ENVIRONMENTAL SAFETY NOTICE Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.
SPECIFICATIONS Model Type Armature Connection Phase Standby Output Prime Output Voltage Frequency Speed Power Factor Aux. AC Power Sound Level db (A) full Load at 23 ft. (7 meters) Weight (No Fuel) Weight (Fuel) Model Type No. of Cylinders Bore x Stroke Displacement Rated Output Starting Coolant Capacity Lube Oil Capacity Fuel Type Fuel Tank Capacity Fuel Consumption Battery Table 1.
DIMENSIONS Figure 1. Dimensions Table 3. Dimensions Reference Letter Dimension in. (mm) Reference Letter Dimension in. (mm) A 21.06 in. (535 mm.) F 72.83 in. (1,850 mm.) B 21.06 in. (535 mm.) G 39.37 in. (1,000 mm.) C 24.21 in. (615 mm.) H 29.53 in. (750 mm.) D 26.38 in. (670 mm.) E 25.00 in. (635 mm.) DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
INSTALLATION Figure 2. Typical Generator Grounding Application PAGE 14 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
INSTALLATION OUTDOOR INSTALLATION GENERATOR GROUNDING Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes. To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.
GENERAL INFORMATION GENERATOR This generator (Figure 3) is a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.
MAJOR COMPONENTS Table 4. Generator Major Components ITEM NO. DESCRIPTION 1 Output Terminal Assembly 2 Auxiliary Receptacles Assembly 3 Muffler Assembly 4 Air Filter Assembly 5 Battery Assembly 6 Generator Assembly 7 Engine Assembly 8 Fuel Tank Assembly 9 Main Circuit Breaker Assembly 10 Control Panel Assembly Figure 3. Major Components DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
CONTROL PANEL 1 2 3 DECREASE INCREASE SUPPLYING LOAD ALARM 5 NOT IN AUTO EDIT RESET RUN ALARM SILENCE LAMP TEST OFF AUTO 4 Figure 4. Control Panel The definitions below describe the controls and functions of the Control Panel (Figure 4). 1. Voltage Regulator Control — Allows ±15% manual adjustment of the generator’s output voltage. 2. Panel Light — Normally used in dark areas or at night time. When activated, panel lights will illuminate.
DIGITAL CONTROLLER PANEL 1 2 3 4 5 SUPPLYING LOAD ALARM NOT IN AUTO 12 ALARM SILENCE LAMP TEST 6 7 EDIT RESET 11 RUN 10 9 OFF AUTO 8 Figure 5. Digital Controller Panel The definitions below describe the controls and functions of the Digital Control Panel (Figure 5). 1. Liquid Crystal Display (LCD) — The LCD serves as the local information source for metering, alarms, pre-alarms, and protective functions. 2.
LCD DISPLAY/GENERATOR CONTROL BOX The definitions below describe the monitoring parameters of the Digital Control Panel Display(Figure 6). Located behind the generator control panel is the Generator Control Box. This box contains some of the necessary electronic components required to make the generator function.
OUTPUT TERMINAL PANEL FAMILIARIZATION OUTPUT TERMINAL PANEL OUTPUT TERMINAL FAMILIARIZATION The Output Terminal Panel (Figure 7) shown below is located on the right-hand side (left from control panel) of the generator. Lift up on the cover to gain access to receptacles and terminal lugs.
OUTPUT TERMINAL PANEL FAMILIARIZATION 120 VAC GFCI Receptacles There are two 120 VAC, 20 amp GFCI (Duplex Nema 5-20R) receptacles provided on the output terminal panel. Each receptacle is protected by a 20 amp circuit breaker. These breakers are located directly above the GFCI receptacles. Remember the load output (current) of both GFCI receptacles is dependent on the load requirements of the U, O, and V output terminal lugs. Pressing the reset button resets the GFCI receptacle after being tripped.
OUTPUT TERMINAL PANEL FAMILIARIZATION Connecting Loads Over Current Relay Loads can be connected to the generator by the output terminal lugs or the convenience receptacles (Figure 12). Make sure to read the operation manual before attempting to connect a load to the generator. An over current relay (Figure 13) is connected to the main circuit breaker. In the event of an overload, both the circuit breaker and the over current relay may trip.
LOAD APPLICATION/GENERATOR OUTPUT SINGLE PHASE LOAD Always be sure to check the nameplate on the generator and equipment to insure the wattage, amperage, frequency, and voltage requirements are satisfactorily supplied by the generator for operating the equipment. Generally, the wattage listed on the nameplate of the equipment is its rated output.
OUTPUT TERMINAL PANEL CONNECTIONS UOV TERMINAL OUTPUT VOLTAGES 1Ø-120 Output Terminal Voltage 240/120V outout voltages can be obtained using the output terminal lugs. 1. Connect the load wires to the output terminal lugs as shown in Figure 16. The voltage regulator (VR), Figure 15 allows the user to increase or decrease the selected voltage. 1Ø-240 Output Terminal Voltage 1. Connect the load wires to the output terminal lugs as shown in Figure 14. Figure 16.
INSPECTION/SETUP CIRCUIT BREAKERS To protect the generator from an overload, a 3-pole, 90 amp, main circuit breaker is provided to protect the U,O and V Output Terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload. Two 50 amp load circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.
INSPECTION/SETUP Refueling Procedure: WARNING 2. Open cabinet doors on the “right side” of the generator (from generator control panel position). Remove fuel cap and fill tank (Figure 20). Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes. 1. Level Tanks — Make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity (Figure 19).
INSPECTION/SETUP COOLANT (ANTIFREEZE/SUMMER COOLANT/ WATER) ISUZU recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the ISUZU Engine Owner’s Manual for further details. CLEANING THE RADIATOR The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air.
INSPECTION/SETUP BATTERY When connecting battery do the following: This unit is of negative ground DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level are not properly maintained. Add only distilled water when replenishment is necessary. 1. NEVER connect the battery cables to the battery terminals when the Control Power Switch is in either the ON position.
GENERATOR START-UP PROCEDURE (MANUAL) BEFORE STARTING STARTING (MANUAL) CAUTION The engine’s exhaust contains harmful emissions. ALWAYS have adequate ventilation when operating. Direct exhaust away from nearby personnel. 1. Place the control power switch on the control panel (Figure 27) in the ON position. WARNING NEVER manually start the engine with the main, GFCI or auxiliary circuit breakers in the ON (closed) position. 1. Place the main, G.F.C.I., and aux.
GENERATOR START-UP PROCEDURE (AUTO) STARTING (AUTO MODE) DANGER Before connecting this generator to any building’s electrical system, a licensed electrician must install an isolation (transfer) switch. Serious damage to the building’s electrical system may occur without this transfer switch. 1. Pressing the AUTO button (Figure 30) on the controller places the Digital Controller in the auto mode. This mode allows the controller to monitor the remote start contacts.
GENERATOR SHUT-DOWN PROCEDURES NORMAL SHUTDOWN PROCEDURE EMERGENCY SHUTDOWN PROCEDURE To shutdown the generator, use the following procedure: 1. Place the main, G.F.C.I., and aux. circuit breakers (Figure 31) in the OFF position. WARNING NEVER stop the engine suddenly except in an emergency. 2. Press the OFF button (Figure 32) on the Digital Controller to shutdown the engine. 1. Place the main, G.F.C.I., and aux. circuit breakers (Figure 31) in the OFF position. Figure 31. Main, Aux.
MAINTENANCE 10 Hrs DAILY X X X X X X Table 11.
MAINTENANCE If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result. This can lead to a loss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists. FUEL ADDITION FUEL TANK INSPECTION In addition to cleaning the fuel tank, the following components should be inspected for wear: Rubber Suspension — look for signs of wear or deformity due to contact with oil.
MAINTENANCE CHECK OIL LEVEL RADIATOR CLEANING Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 17 The radiator (Figure 36) should be sprayed (cleaned) with a high pressure washer when excessive amounts of dirt and debris have accumulated on the cooling fins or tube.
MAINTENANCE JACKET WATER HEATER AND INTERNAL BATTERY CHARGER 120 VAC INPUT RECEPTACLES (OPTIONAL) This generator can be optionally equipped with two 120 VAC, 20 amp input receptacles located on the output terminal panel. The purpose of these receptacles is to provide power via commercial power to the jacket water heater and internal battery charger. If the generator will be used daily, the battery should normally not require charging.
TRAILER MAINTENANCE TRAILER MAINTENANCE This section is intended to provide the user with generic trailer service and maintenance information. The service and maintenance guidelines referenced in this section refer to a wide range of trailers. Remember periodic inspection of the trailer will ensure safe towing of the generator and will prevent personal injury and damage to the equipment. The definitions below describe some of the major components of a typical trailer that would be used with generator. 1.
TRAILER MAINTENANCE BRAKES Hydraulic Surge Brakes Trailer brakes should be inspected the first 200 miles of operation. This will allow the brake shoes and drums to seat properly. After the first 200 mile interval, inspect the brakes every 3,000 miles. If driving over rough terrain, inspect the brakes more frequently. Figure 38 displays the major hydraulic surge brake components that will require inspection and maintenance.
TRAILER MAINTENANCE TIRES/WHEELS/LUG NUTS Suspension Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched. The leaf suspension springs and associated components (Figure 39) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners. Replace all damaged parts (suspension) immediately.
TRAILER MAINTENANCE Lug Nut Torque Requirements It is extremely important to apply and maintain proper wheel mounting torque on the trailer. Be sure to use only the fasteners matched to the cone angle of the wheel. Proper procedure for attachment of the wheels is as follows: 1. Start all wheel lug nuts by hand. 2. Torque all lug nuts in sequence (Figure 40). DO NOT torque the wheel lug nuts all the way down. Tighten each lug nut in 3 separate passes as defined by Table 15. 3.
TRAILER WIRING DIAGRAM Figure 41. Trailer/Towing Vehicle Wiring Diagram DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
GENERATOR WIRING DIAGRAM Figure 42. Generator Wiring Diagram PAGE 42 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
ENGINE WIRING DIAGRAM Figure 43. Engine Wiring Diagram DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
TROUBLESHOOTING (GENERATOR) Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 16 shown below for diagnosis of the Generator. If the problem cannot be remedied, consult our company’s business office or service plant. Symptom High Voltage Output Circuit Breaker Tripped Table 16. Generator Troubleshooting Possible Problem Solution Is wiring connection loose? Check wiring and repair. Is AVR defective? Replace if necessary.
PROTECTIVE DEVICES PROTECTIVE DEVICES When ready to restart the generator, make sure all circuit breakers are OFF. Also check and make sure the that OFF button on the Digital Controller has been pressed to clear the system and that the OFF LED on the Digital Controller is RED. Restart the generator as outlined in the Manual/ Auto startup sections within this manual. Protection devices and emergency stop devices are provided for protection of the generator against trouble during operation.
EXPLANATION OF CODE IN REMARKS COLUMN The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. NOTICE The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed. SAMPLE PARTS LIST NO. 1 2% 2% 3 4 PART NO. PART NAME QTY. REMARKS 12345 BOLT......................1 .....
SUGGESTED SPARE PARTS DCA20SPXU2D WHISPERWATT GENERATOR WITH ISUZU BV-4LE2 DIESEL ENGINE 1 to 3 units QTY. P/N DESCRIPTION 1............B1312500403 .......HOSE, RADIATOR UPPER 1............B1312500503 .......HOSE, RADIATOR LOWER 1............0602011079..........RADIATOR CAP 1............0605505070..........FUEL CAP 1............0602122272..........UNIT, OIL PRESSURE 1............0602123275 .........UNIT, WATER TEMPERATURE 6............8980374810..........FILTER, FUEL CARTRIDGE 6............8944370220.......
GENERATOR ASSY. PAGE 48 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
GENERATOR ASSY. NO. 1 1-1# 1-2# 1-3# 1-4# 1-5# 1-6# 1-8# 1-9# 1-10# 1-11# 2 2A 2B 3 4 4-1 5 6 7 8 9 10 11 12 13 13A 13B 14 15 16 17 18 19 PART NO.
CONTROL BOX ASSY. PAGE 50 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
CONTROL BOX ASSY. NO. 1 1- 1 1- 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16A 16B 17 17A 17B 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 34A 35 36 37 38 39 39 40 PART NO.
ENGINE AND RADIATOR ASSY. PAGE 52 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
ENGINE AND RADIATOR ASSY. NO. 1 1A 1-1 2 3 4 5 6 7 8 9 9-1 9-2 9-3 10 11 12 13 14 15 16 17 17A 18 19 20 21 22 22A 23 24 25 26 27 28 29 30 PART NO.
ENGINE AND RADIATOR ASSY. (CONTINUED) PAGE 54 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
ENGINE AND RADIATOR ASSY. (CONTINUED) NO. 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 PART NO.
OUTPUT TERMINAL ASSY. ADD THE FOLLOWING DIGITS AFTER THE PART NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT: 1-ORANGE 5-BLACK 2-WHITE 6-CATERPILLAR YELLOW 3-SPECTRUM GREY 7-CATO GOLD 4-SUNBELT GREEN 8-RED THE SERIAL NUMBER MAY BE REQUIRED. PAGE 56 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
OUTPUT TERMINAL ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 11A 11B 12 12A 13 13A 13B 13C 14 15 16 17 18 19 20 21 22 22-1 23 24 25 26 26A 27 28 29 30 31 32 33 PART NO.
BATTERY ASSY. PAGE 58 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
BATTERY ASSY. NO. 1 2 3 4 5 6 7 8 8A PART NO. 0602220185 B9310500014 M9103000304 0602220920 0040006000 M1348400204 M2346400104 0016910020 0040510000 PART NAME BATTERY BATTERY SHEET BATTERY BAND BATTERY BOLT SET WASHER, LOCK BATTERY CABLE BATTERY CABLE HEX HEAD BOLT TOOTHED WASHER QTY. 1 1 1 2 2 1 1 1 3 REMARKS DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
MUFFLER ASSY. PAGE 60 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
MUFFLER ASSY. NO. 1 2 3 4 5 6 7 8 9 PART NO. M1330100803 0016908020 M1333002803 0602320100 M1333200014 0207008000 0016908035 M1330400804 0016906016 PART NAME MUFFLER HEX HEAD BOLT EXHAUST PIPE GASKET GASKET HEX NUT HEX HEAD BOLT COVER HEX HEAD BOLT QTY. 1 4 1 1 1 4 4 2 4 REMARKS DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
FUEL TANK ASSY. PAGE 62 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
FUEL TANK ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14A 15 16 17 17A 18 19 20 21 22 23 24 25 26 PART NO. M1363000212 0605505070 M1363200004 M9310500104 0016908020 0207308000 0222100080 M9200000003 M0920020004 0150000018 0016906020 M1363400104 0605515198 8943672922 8980374810 M1366700104 0016908020 8970398340 8944370220 0016906025 0191200900 0191200300 0191200650 0191201100 0605515108 0605515198 0605501078 0605516090 PART NAME QTY.
ENCLOSURE ASSY. PAGE 64 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
ENCLOSURE ASSY. NO. 1 2 3 4 4A 5 6 6A 7 8 9 10 10A 10B 11 12 13 14 14A 15 16 17 18 19 19A 20 21 21A 22 23 24 25 26 26A 27 28 29 30 31 31A 31B 32 PART NO.
ENCLOSURE ASSY. (CONTINUED) PAGE 66 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
ENCLOSURE ASSY. (CONTINUED) NO. 33 33A 34 34A 35 35A 36 36A 37 38 39 40 40A 41 42 43 44 45 46 47 48 49 50 50A 51 51A 52 52A 53 54 55 PART NO.
RUBBER SEALS ASSY. PAGE 68 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
RUBBER SEALS ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 PART NO.
NAMEPLATE AND DECALS ASSY. PAGE 70 — DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
NAMEPLATE AND DECALS ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 PART NO.
TERMS AND CONDITIONS OF SALE — PARTS PAYMENT TERMS 5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products. a. SPECIAL EXPEDITING SERVICE Terms of payment for parts are net 30 days.
NOTES DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV.
OPERATION AND PARTS MANUAL HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Corporate Office 18910 Wilmington Ave. Carson, CA 90746 Contact: mq@multiquip.com MQ Parts Department Tel.