6. Press the generator's pushbutton start switch
(Figure 17) and listen for the engine to start.
Figure 17. Start Switch (GA6HEB Only)
7. If the engine has started, slowly return the choke lever
(Figure 14) to the OpeN position. If the engine has not
started repeat steps 1 through 6.
8. Before the generator is placed into operation, run the
engine for 3-5 minutes. Check for abnormal smells,
fuel leaks, and noises that would associate with lose
components.
9. Place idle control switch (Figure 18) in the 
position. This will allow the engine speed to run at about
3600 RPM's.
Figure 18. Idle Control Switch (OFF)
OFF
ON
OFF
GA-6HB
GA-6HEB
NOTICE
Placing the idle control switch in the  position
(Figure 18) allows the engine to operate at a maximum
speed of about 3600 RPM's.
When the idle control switch (Figure 19) is placed in the
up position (ON), the generator will run at idle speed
(2200 RPM's) until a load is applied, at that time the
engine speed will increase to 3600 RPM's as long as
a load is being applied.
When the load is not in use, the engine speed will drop
back to the idle mode after about 3 seconds.
Figure 19. Idle Control switch (ON)
10. Place main circuit breaker (Figure 20) in the ON
position.
Figure 20. Main Circuit Breaker (ON)
11. Read voltmeter on front panel of generator (Figure 21)
and verify that 120 VAC is displayed. Using an external
voltmeter as shown in Figure 19, verify that 120 VAC
is present at the 120V twist-lock and GFCI duplex
receptacles.
Figure 21. 120V Twist-Lock/GFCI Receptacles
ON
OFF
GA-6HB
GA-6HEB
ON
OFF
ON
120V
OFF
V~
V
300 mV
A
A~
V
COM
120 VAC
GFCI
L5-30R
120
V
G
W
120VAC
X