OPERATION AND PARTS MANUAL GLOBUG MODEL GB4000 LIGHT TOWER MOUNT TYPE BALLOON LIGHT SERIAL NO. G3100044 AND ABOVE Revision #1 (02/25/14) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
NOTES PAGE 2 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
TABLE OF CONTENTS GB4000 BALLOON LIGHT Table of Contents...................................................... 4 Parts Ordering Procedures....................................... 5 Safety Information............................................... 6-13 Specifications......................................................... 14 Dimensions............................................................. 15 Footcandle Plot....................................................... 16 General Information................
www.multiquip.com PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Order via Internet (Dealers Only): Best Deal! Effective: January 1st, 2006 If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip. com. Order parts on-line using Multiquip’s SmartEquip website! ■ View Parts Diagrams ■ Order Parts ■ Print Specification Information To obtain an MQ Account, contact your District Sales Manager for more information.
SAFETY INFORMATION Do not operate or service the equipment before reading the entire manual. Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the safety messages and operating instructions could result in injury to yourself and others.
SAFETY INFORMATION GENERAL SAFETY CAUTION NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations. NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication. NEVER operate this equipment under the influence of drugs or alcohol.
SAFETY INFORMATION LIGHT TOWER SAFETY DANGER NEVER operate the equipment in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death. WARNING NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.
SAFETY INFORMATION ENGINE SAFETY NOTICE DANGER The engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled. The engine of this equipment requires an adequate free flow of cooling air. NEVER operate this equipment in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause injury to people and property and serious damage to the equipment or engine.
SAFETY INFORMATION FUEL SAFETY DANGER DO NOT start the engine near spilled fuel or combustible fluids. Diesel fuel is extremely flammable and its vapors can cause an explosion if ignited. ALWAYS refuel in a well-ventilated area, away from sparks and open flames. ALWAYS use extreme caution when working with flammable liquids. DO NOT fill the fuel tank while the engine is running or hot.
SAFETY INFORMATION TRANSPORTING SAFETY If lifting through pockets, make sure forks of forklift are inserted in pockets as far as possible before lifting. CAUTION Before lifting, make sure that light tower parts are not damaged and screws are not loosened or lost. Place chock blocks underneath wheel to prevent rolling while parked. ALWAYS make sure crane or lifting device has been properly secured to lifting hook of the equipment.
SAFETY INFORMATION ELECTRICAL SAFETY DANGER The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn generator and all circuit breakers OFF before performing maintenance on the generator. NEVER insert any objects into the output receptacles during operation. This is extremely dangerous. The possibility exists of electrical shock, electrocution or death.
SAFETY INFORMATION BATTERY SAFETY DANGER DO NOT drop the battery. There is a possibility that the battery will explode. DO NOT expose the battery to open flames, sparks, cigarettes, etc. The battery contains combustible gases and liquids. If these gases and liquids come into contact with a flame or spark, an explosion could occur. WARNING ENVIRONMENTAL SAFETY NOTICE Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.
SPECIFICATIONS Table 1. Specifications Model Lamp Fan Type Number of Bulbs Current Voltage Lumens Current Voltage Storage Dimensions Working Balloon Weight Bracket & J-Box Total Appropriate Generator GB4000 1000 W Metal Halide (X4) 4 37.2 A (9.3 A x 4) 120 V 428,000 (10,700 x 4) lm 1.2 A 24 VDC 15.7 x 15.7 x 45.6 in (400 x 400 x 1160 mm) 55.1 x 55.1 x 47.2 in (1400 x 1400 x 1200 mm) 39.9 lb (18.1 kg) 19.2 lb (8.7 kg) 59.1 lb (26.8 kg) 3.
DIMENSIONS A C D B CLOSED OPENED Figure 1. Dimensions Table 2. Dimensions Reference Letter Dimension in. (mm) A 15.7 (400) B 46 (1,170) C 55.1 (1400) D 41.7 (1,060) GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
FOOTCANDLE PLOT 30 20 10 5 2 1 0.5 0.25 1 grid = 40 ft. Illuminance (Footcandle) 30 20 10 5 Diameter (Feet) 60 78 98 149 205 259 314 426 46 2 1 0.5 0.25 0.1 Figure 2. Footcandle Plot PAGE 16 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
GENERAL INFORMATION The GB4000 lamp fixture is a difused balloon light that is designed to be mounted and operated on most conventional mobile light tower masts. Its design and features permit clean, difused light to be cast uniformly over 232 feet (70.7 meters). The shadow-less lighting dramatically reduces glare in the work area. This type of lighting improves safety and enhances the illuminated area. The GB4000 is ideal for highway work, construction job sites, security support, and special events.
COMPONENTS 1. Lamp Fixture — Made of heat resistant polyester balloon and four 1000-watt metal halide lamps. 2. Locking Pin — Locks the lamp fixture in place when attached to the pole on the bracket. 3. Balloon Power Cable — Provides AC power to the lamps, fan and balloon inflation circuit. 1 4. Adapter Plate — Attaches to the T-Bar and mast interface of the light tower to allow the GB4000 to be installed. NOTICE This adapter plate (item 4) fits most conventional light tower masts. 5.
SETUP PREPARATION POWER DISCONNECTION 1. Place the light tower in an area free of dirt and debris with enough clearance as not to interfere with any overhead obstructions. Make sure it is on secure level ground with chock blocks underneath each wheel to prevent the light tower from rolling. 1. For LT12D light towers, disconnect the negative cable (black) from battery. See Figure 5.
SETUP LAMP ADAPTER PLATE MOUNTING INSTALLATION 1. Remove the adapter plate kit hardware from its container. 2. Before proceeding make sure the light tower mast is in the stow position (down) and the cradle lock/release pin has been inserted and the mast is locked. 3. Attach the lamp adapter plate to the T-Bar as shown in Figure 7. Align adapter plate so that adapter spacer notch fits over screw on T-Bar. Pay close attention to the orientation of the two support brackets. 5.
SETUP VIEW FROM BACK SIDE BUBBLE LEVEL 2 1 LOCK WASHER (4) HEX NUT (4) 3 SPACER 1 LOW END 2 4 FLUSH W/ T-BAR BOTTOM FLAT WASHER (8) SUPPORT BRACKET (2) BOLT T-BAR BOLT (4) LAMP ADAPTER PLATE T-BAR 1 BACK SIDE UNDERNEATH 3 BOLT 2 2 LAMP ADAPTER PLATE 4 SUPPORT BRACKET J1 NOTES: J2 1 It is important for the adapter SPACER to seat against the T-Bar as shown above. 2 For proper alignment of the adapter plate, use of a bubble level is required. Figure 7.
SETUP JUNCTION BOX MOUNTING LAMP MOUNTING 1. Secure the junction box (Figure 8) to the adapter plate using the supplied bolts (2), lock washer (2), and flat washer (2). Tighten mounting bolts securely. 1. Place the GB4000 lamp fixture onto the lamp adapter plate pole as shown in Figure 9. LAMP T-BAR ADAPTER PLATE 2. Insert locking pin into hole opening on pole, then insert cotter pin to lock pin in place. BALLOON POWER CABLE BOLT (2) 1.
LAMP CABLE CONNECTIONS On the T-Bar (Figure 10) there are four power receptacles J1, J2, J3 and J4. These receptacles provide AC power to the existing rectangular lamps. When the GB4000 lamp assembly is employed, these receptacles are used to connect the GB4000. Refer to Figure 10. GB4000 JUNCTION BOX T-BAR 1 2 3 4 NOTE: CABLE FROM LAMP 1 MUST BE CONNECTED FOR OTHER LAMPS TO OPERATE AND FOR BALLOON TO INFLATE.
OPERATION REMOVING BALLOON PROTECTIVE COVER CAUTION 4. Once, the engine has started, place the main circuit breaker switch (Figure 12) on the LT12 control panel in the ON position. DO NOT use excessive force when zipping or unzipping the balloon. The possibility exists of the zipper tearing, which would make the balloon unusable. 1. Expose the balloon by unsnapping the buttons and unzipping the protective cover as shown in Figure 11.
OPERATION INFLATING BALLOON AND TURNING ON LAMPS (MLT ONLY) 5. Next, turn on lamp circuit breakers The balloon should begin to inflate and the lamps will light. 1. On MLT series light towers, reconnect the 4-pin power cable (Figure 13) to the 120 VAC twist-lock receptacle on the front panel of the generator. 6. Secure any unused lamp cables. DEFLATING AND STORING BALLOON 1. Turn lamps OFF and allow to cool for at least five minutes. MLT LIGHT TOWER 2.
MAINTENANCE REPLACING LAMP 3. Press the tabs on the lamp holder and push up lamp holder to release it from lamp. Do the same to the lower lamp if necessary. See Figure 17. DANGER Never attempt to replace lamp in a wet place. The possibility exists of electric shock. WARNING Always allow sufficient time for the lamp to cool down before replacing. The possibility exists of severe burns if hot lamp is touched.
MAINTENANCE NOTICE Do not use excessive force when screwing the lamp to prevent lamp from breaking. 3. Slide in the new replacement balloon over the top of the lamp guard assembly. See Figure 22. 6. Secure lamp holder on top of the lamp. 7. Reinstall lamp guard. 8. Pull down balloon and zip the bottom zipper to cover lamp. INSTALL NEW BALLOON REPLACING BALLOON 1. Unzip the top and bottom of the balloon. See Figure 20. Figure 22. Replacing Balloon 4. Zip up the top and bottom of the new balloon.
MAINTENANCE SYMPTOM Lamp does not light. Lamp only lights for a short time. Balloon does not inflate. Only Fan is working. Shuts down after 30 seconds. Table 3.
WIRING DIAGRAM LAMP 2 TOP LAMP 1 TOP LAMP 1 BOTTOM SOCKET SOCKET ① LAMP 2 BOTTOM SOCKET SOCKET M M M M M F F M M M F DC FAN MOTOR CABLE (POLE) R F M F F F F ① CABLE (POLE) W M M M RELAY ① BLUE M M M M M M M F F F F F F F F F F F CABLE (BALLOON) F M F M DC CONVERTER ① DF E C BAG GREEN BALLOON CABLE (PANEL) D F E C BA G M M M M M F F M M M F F GREEN M MICROSWITCH F F F F M BOX RELAY F F 16AWG-3C 16AWG-3C 16AWG-3C 16AWG-3C ① CABLE
EXPLANATION OF CODE IN REMARKS COLUMN The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. NOTICE The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed. SAMPLE PARTS LIST NO. 1 2% 2% 3 4 PART NO. PART NAME QTY. REMARKS 12345 BOLT .....................1 .....
SUGGESTED SPARE PARTS GB4000 BALLOON LIGHT 1 to 3 units Qty. P/N Description 2............E000127300..........LAMP 2............A100097802..........BALLOON COVER CP 3............A400038301..........FILTER NOTICE Part numbers on this Suggested Spare Parts list may supersede/replace the part numbers shown in the following parts lists. GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
NAMEPLATE AND DECALS B UR N HAZAR D G B 4000 To prevent burns , NE V E R touch lamp while lamp is on. Lamp s urface gets extremely hot! A LWAY S allow s ufficient time for lamp to c ool down before touching. A-4002526-00 3 120V 60Hz 4000 W 4 Metal halide lamp 1000W× 4 TYP E M47 G XXXXXX AV E R T IS S E ME NT R IS QUE DE B R ÛL UR E P our éviter les brulures , NE J A MA IS toucher la lampe, le ballas t ou le couvercle tant que la lampe es t allumée.
NAMEPLATE AND DECALS NO. PART NO. 1 A400290900 1 A400324200 2 A400252500 2 A400336800 3 A400252600 3 A400336900 4 5 A400252800 5 A400336700 6 A400336600 6 A400337000 7 A400326400 8 A400325000 PART NAME QTY. REMARKS DECAL; CAUTION, LAMP INFORMATION (ENGLISH) 1 DECAL; CAUTION, LAMP INFORMATION (FRENCH) 1 DECAL; DANGER, ELECTRICAL SHOCK HAZARD (ENGLISH) 1 DECAL; DANGER, ELECTRICAL SHOCK HAZARD (FRENCH) 1 DECAL; WARNING, BURN HAZARD (ENGLISH) 1 DECAL; WARNING, BURN HAZARD (FRENCH) 1 DECAL; SERIAL PLATE......
ELECTRICAL ASSY. 1 33 34 32 33 39 37 34 22 21 35 42 41 40 38 64 8 9 38 4 37 18 15 5 36 14 43 26 7 62 63 23 16 25 3 6 10 62 63 17 12 19 27 45 47 46 49 12 14 20 15 2 17 46 47 17 19 48 51 36 23 16 17 18 25 20 20 50 12 11 17 52 53 21 22 16 5 54 55 56 57 58 59 36 7 27 9 8 23 27 26 1 60 17 13 44 36 2 11 61 28 24 31 29 30 PAGE 34 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
ELECTRICAL ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 PART NO.
ELECTRICAL ASSY. (CONTINUED) 1 33 34 32 33 39 37 34 22 21 35 42 41 40 38 64 8 9 38 4 37 18 15 5 36 14 43 26 7 62 63 23 16 25 3 6 10 62 63 17 12 19 27 45 47 46 49 12 14 20 15 2 17 46 47 17 19 48 51 36 23 16 17 18 25 20 20 50 12 11 17 52 53 21 22 16 5 54 55 56 57 58 59 36 7 27 9 8 23 27 26 1 60 17 13 44 36 2 11 61 28 24 31 29 30 PAGE 36 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
ELECTRICAL ASSY. (CONTINUED) NO. 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 PART NO.
BRACKET AND J-BOX ASSY. PAGE 38 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
BRACKET AND J-BOX ASSY. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 PART NO. A200102501 A300282800 A300282700 0033304000 0024304008 0023305015 0033104000 A100088602 E000122700 A400288001 A300215302 A300283800 0013112130 0013510025 0023303012 E000128500 0043112000 0043212000 A400287902 0023205015 0033112000 A400287801 A400334300 0033103000 PART NAME QTY. REMARKS BOX (RELAY) 1 RUBBER CAP 1 PLATE CAP 1 CAP NUT (M4) 8 SCREW TRUSS (M4x8) 4 SCREW & WASHER (M4x12)..........................
TERMS AND CONDITIONS OF SALE — PARTS PAYMENT TERMS 5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products. a. SPECIAL EXPEDITING SERVICE Terms of payment for parts are net 30 days.
NOTES GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV.
OPERATION AND PARTS MANUAL HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Corporate Office 18910 Wilmington Ave. Carson, CA 90746 Contact: mq@multiquip.com MQ Parts Department Tel.