OPERATION AND PARTS MANUAL MODELS: ST2037 ST2047 ST2047B ST2038P ST2040T SUBMERSIBLE PUMPS Revision #3 (06/15/10) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
ST2037, 47, 47B, 40T, 38P SERIES SUB. PUMPS — TABLE OF CONTENTS Multiquip ST2037, ST2047, ST2047B ST2038P and ST2040T Submersible Pumps Table Of Contents ..................................................... 2 Parts Ordering Procedures ....................................... 3 Here's How to Get Help ............................................ 4 Safety Message Alert Symbols ................................. 5 Rules For Safe Operation ...................................... 6-7 Dimensions ....................
www.multiquip.com PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Order via Internet (Dealers Only): Best Deal! Effective: January 1st, 2006 If you have an MQ Account, to obtain a Username and Password, E-mail us at: parts@multiquip. com. Order parts on-line using Multiquip’s SmartEquip website! N View Parts Diagrams N Order Parts N Print Specification Information To obtain an MQ Account, contact your District Sales Manager for more information.
NOTE PAGE PAGE 4 — ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
ST2037, 47, 47B, 38P, 40T SUB. PUMP— SAFETY MESSAGE ALERT SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — RULES FOR SAFE OPERATION CAUTION Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used when operating the ST2037, ST2047, ST2047B, ST2038P, and ST2040T Submersible Pump: ■ NEVER use gas piping as an electrical ground.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — RULES FOR SAFE OPERATION local codes before operating pump. Severe injury or death by electrocution can result from operating an ungrounded pump. . Emergencies ■ ALWAYS know the location of the nearest fire extinguisher. WARNING- Risk of Electric Shock This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — DIMENSIONS Figure 1. Submersible Pump Dimensions PAGE 8 — ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — SPECIFICATIONS TABLE 1. SPECIFICATIONS Model ST-2037 ST-2047 / ST-2047B Type Centrifugal Submersible Pump Centrifugal Submersible Pump Nitorile Rubber over Steel Impeller ST-2038P ST-2040T Centrifugal Submersible Trash Submersible Pump Pump Nitorile Rubber over Nitorile Rubber Steel over Steel Nitorile Rubber over Steel Suction & Discharge Size 2.00 in. (50 mm) 2.00 in. (50 mm) 2.00 in. (50 mm) 2.00 in.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — GENERAL INFORMATION Introduction The Multiquip Model ST2037, ST2047, ST2047B, ST2038P, and ST2040T submersible pumps are designed to pump water and is used for the draining (de-watering) of swimming pools, well casings construction sites, cofferdams, manholes, transformer vaults and excavations. A Nitorile rubber over steel impeller is attached to the output shaft of a 1HP electric motor which provides adequate power for general purpose pumping.
ST2037, 47, 47B,38P, 40T SUB. PUMP — COMPONENTS ST2037, ST2047, ST2047B ST2038P ST2040T Figure 2. Submersible Pump Components Figures 2 shows the location of the basic components, for the ST2037, ST2047, ST2047B, ST2038P, and ST2040T submersible pumps. Listed below is a brief explanation of each component. 1. 2. 3. 4. 5. 6. Carrying Handle – Always carry the submersible pump by its handle. NEVER! carry the pump by its power cord.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — FLOAT SWITCHES Float Switch Theory Design Features Mercury monitoring is a mercury-switch actuated, liquid level control that has proven to be more economical and longer lasting than other types of liquid-level control systems, easily replacing and improving upon diaphragm switches, air bubble systems and electromechanical switches most often relied upon in the past. Constructed of rigid, durable ABS polymer ultrasonically welded.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — FLOAT SWITCH (PIGGY-BACK) Float Switch Single or dual control float switches (Figure 6) can be used for the unattended operation of the submersible pump. When using the piggy-back power configuration (plug), the pumps DO NOT require the use of a control box. In this configuration (piggy-back), the SW-1 (single float switch) or SW-2 (dual float switch) are required. The illustration below is an example of a single float switch application. Mounting The Float Switch 1.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — FLOAT SWITCH (CONTROL BOX) Control Box (CB3) For special remote pumping applications of the submersible pump, a control box (Model CB3) may be required. This water resistant control box provides watertight housing and glands to prevent water from leaking into the box, and a float switch interface. When using the CB3 control box, only the SW-1WOP float switch (2) can be used (no plug, bare wires). Shown below (Figure 7) is a wiring layout of the CB3 control box.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — OPERATION Hose Connections 1. Connect a 2-inch hose to the discharge port on the pump as shown in Figure 8. Make sure that the hose is attached correctly to the discharge port. Pump Power Connections (Piggy-Back Cord Only) 1. Make sure the circuit breaker supplying power to the pump is in the OFF position. 2. Connect the float switch or switches to the AC power receptacle as shown in Figure 6. Attaching Lifting Rope 1.
ST2037, 47, 47B, 38P, 40T SUB. PUMP— CONTROL BOX INSTALLATION DANGER The ST2037, ST2047, ST2047B, ST2038P, and ST2040T submersible pumps are also designed to work with a control box (Model CB3). This control box contains the necessary electronics (float switch connections) to operate the pump. Remember this control box contains hazardous voltages. Disconnect all sources of power before installing or servicing.
ST2037, 47, 47B, 38P, 40T SUB. PUMP— CONTROL BOX INSTALLATION Connecting AC Power to the Control Box 1. 2. 3. The AC power cord (input) should have three wires. Each wire is color coded. The colors are WHITE, BLACK and GREEN. Remove the AC input connector housing from the control box, then route the power cord through the cable gland on the control box. Connect the AC power cord to the contactor as shown in Figure 7 and Table 6. 2.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — CLEAN-UP AND MAINTENANCE Pump Shut-Down/Clean-up For Model ST2037, ST2047, ST2047B and ST2038P: 1. Remove the power from the pump by turning off the circuit breaker or switch that provides power to the pump. Remember to make sure that hands are dry (not wet), and feet are not standing in water when removing disconnecting power from the pump. 1. Position pump upside down. 2. Using the lifting rope, lift the pump up from its current position.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — MAINTENANCE Figure 11. Checking Hydraulic Oil ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — TROUBLESHOOTING Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 8 (Pump Troubleshooting) as a basic guideline for troubleshooting the pump. If the problem cannot be remedied, contact Multiquip's service department. TABLE 8.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — PERFORMANCE CURVES Figure 12. Pump Performance Curves ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
ST2037, 47, 47B, 38P, 40T SUB. PUMP — PUMP WIRING DIAGRAM 115 VAC, 60 Hz. ELECTRIC MOTOR WIRING DIAGRAM Capacitor Thermal Protector LEAD WIRES GREEN (GROUND) U V 1 BLACK (LINE) WHITE (NEUTRAL) 3 P AUXILIARY COIL 2 MAIN COIL AC POWER CORD Motor CONTROL BOX WIRING DIAGRAM CONTACTOR PUMP POWER CORD SUBMERSIBLE PUMP BLACK WHITE GREEN WHITE T1 INPUT POWER CORD L1 BLACK COIL EXTERNAL 1-PHASE (115 VAC, 60 Hz.
NOTE PAGE ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
EXPLANATION OF CODE IN REMARKS COLUMN The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions. NOTICE The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed. SAMPLE PARTS LIST NO. 1 2% 2% 3 4 PART NO. PART NAME QTY. REMARKS 12345 BOLT......................1 .....
ST2037, 47, 47B, 38P, 40T SUB. PUMP — SUGGESTED SPARE PARTS ST2037, ST2047, ST2047B ST2038P, ST2040T SUBMERSIBLE PUMP 1 TO 3 UNITS Qty. P/N Description Remarks 1 ............ 0201503UL120 .............. AC CORD WITH GLAND ........... ST2037, ST2038P, ST2040T 1 ............ 0202010UL120 .............. AC CORD WITH GLAND ........... ST2047 1 ............ 020S500UL060 .............. MECHANICAL SEAL 1 ............ 020S500UL074 .............. PACKING ST2037,47, 47B, 38P, 40T SUB.
ST2037, ST2047, ST2047B — ELECTRIC SUBMERSIBLE PUMP ASSY. ST2037 AND ST2047 ELECTRIC SUBMERSIBLE PUMP ASSY. 444 7 265 125 358 431 67 893 894 121 103 895 896 120 102 34 65 127 174 829 3 829 1 214 53 5 129 4 170 131 1 157 224 119 445 446 238 264 74 146 891 302 918 60 NOTES: MODEL ST2037 ONLY HEAT-TREATED IMPELLER WITH KEY. 300 299 PAGE 26 — ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
ST2037, ST2047, ST2047B — ELECTRIC SUBMERSIBLE PUMP ASSY. ST2037 AND ST2047 ELECTRIC SUBMERSIBLE PUMP ASSY.
ST2040T — ELECTRIC SUBMERSIBLE PUMP ASSY. ST2040T ELECTRIC SUBMERSIBLE PUMP ASSY. PAGE 28 — ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
ST2040T — ELECTRIC SUBMERSIBLE PUMP ASSY. ST2040T ELECTRIC SUBMERSIBLE PUMP ASSY.
ST2038P— ELECTRIC SUBMERSIBLE PUMP ASSY. ST2038P - ELECTRIC SUBMERSIBLE PUMP ASSY. PAGE 30 — ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
ST2038P— ELECTRIC SUBMERSIBLE PUMP ASSY. ST2038P - ELECTRIC SUBMERSIBLE PUMP ASSY.
TERMS AND CONDITIONS OF SALE — PARTS PAYMENT TERMS 5. Parts must be in new and resalable condition, in the original Multiquip package (if any), and with Multiquip part numbers clearly marked. 6. The following items are not returnable: Multiquip reserves the right to quote and sell direct to Government agencies, and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products. a. SPECIAL EXPEDITING SERVICE Terms of payment for parts are net 30 days.
NOTE PAGE ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV.
OPERATION AND PARTS MANUAL HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Corporate Office 18910 Wilmington Ave. Carson, CA 90746 Contact: mq@multiquip.com MQ Parts Department Tel. (800) 421-1244 Fax (800) 537-3927 Mayco Parts 800-427-1244 310-537-3700 Fax: 800-672-7877 Fax: 310-637-3284 Warranty Department 800-306-2926 310-537-3700 Fax: 800-672-7877 Fax: 310-637-3284 Service Department 800-421-1244, Ext. 279 310-537-3700, Ext.