MultiFRAD 200-Series Models FR221 & FR221/V2 User Guide
User Guide 88311950 Revision A MultiFRAD (Models FR221 and FR221/V2) This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright © 1999, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose.
Contents Chapter 1 - Introduction and Description Introduction ................................................................................................................................................ 6 Preview of this Guide ................................................................................................................................. 7 Front Panel Description ............................................................................................................................
Point to Point Setup ................................................................................................................................. 57 Frame Relay Setup .................................................................................................................................. 58 Data Port Configuration ............................................................................................................................ 63 Changing Channel Parameters (FR221/V2 only) ..........
Chapter 1 - Introduction and Description
MultiFRAD User Guide Introduction Welcome to Multi-Tech's new MultiFRAD™, Models FR221 and FR221/V2, Routers/ Two-Port Frame Relay Access Devices (FRADs). The “/V2” version includes a “Voice option” with two voice/fax channels (with three voice/fax interfaces on each voice channel). Both versions have a 10 Mbps Ethernet LAN interface, an internal DSU for the WAN interface, and a command port for configuration.
Chapter 1 - Introduction and Description Preview of this Guide This User Guide describes the MultiFRAD and details how to install and configure it. The information contained in each chapter is as follows: Chapter 1 - Introduction and Description Chapter 1 describes the MultiFRAD and includes front panel descriptions, back panel connectors, and relevant technical specifications. Chapter 2 - Installation This chapter provides information on unpacking and cabling your MultiFRAD.
MultiFRAD User Guide Front Panel Description The front panel of the FR221 has four groups of LEDs that provide the status of the LAN connection and the general status of the MultiFRAD. The FR221/V2 has an additional group of LEDs for its two voice/fax channels. From left to right, the first group of LEDs indicates whether the self test passed or failed and if the power On/Off switch on the back of the MultiFRAD is switched On. The Ethernet LEDs display LAN activity; i.e.
Chapter 1 - Introduction and Description FXS VOICE/FAX CHANNELS (FR221/V2 Only) Foreign Exchange Station indicator lights when the voice/fax Channel is configured for FXS operation. FXO Foreign Exchange Office indicator lights when the voice/fax Channel is configured for FXO operation. E&M Ear and Mouth indicator lights when the voice/fax Channel is configured for E&M operation. FAX Fax indicator lights when there is fax traffic on the voice/fax Channel.
MultiFRAD User Guide Back Panel Description All the cable connections to the MultiFRAD are made at the back panel. Four categories of signal cables are used on the MultiFRAD: Ethernet, Channels, Command Port, and Trunk (RS232/V.35). The back panel connectors are shown in Figure 1-3 and described in the following groups. VOICE/FAX CHANNEL 1 VOICE/FAX CHANNEL 2 GND E&M FXO FXS DIGITAL ETHERNET RS232 10BASE-T COMMAND E&M FXO FXS CHANNEL 2 (RS232C/V.35) I O DSU TRUNK (RS232C/V.
Chapter 1 - Introduction and Description Shunts There are three shunts (Figure 1-4) on the printed circuit board for the composite link trunk connection and the two data Channels. Trunk RS232 Shunt Position Trunk V.35 Shunt Position Channel 1 V.35 Shunt Position Channel 2 V.35 Shunt Position Figure 1-4. Shunts Initially, all three shunts are installed in their default RS232 locations and the associated V.35 16-pin DIP sockets are empty.
MultiFRAD User Guide Technical Specifications The MultiFRAD conforms to the following specifications: • • • • Provides access to Frame Relay Networks for IP, IPX, bridged LAN traffic, Async and HDLC Sync devices DSU Port - 56 Kbps, synchronous Data ports can be configured as either EIA-232 or V.35 Command Port - 19.2 Kbps, asynchronous Data Ports • • • • Supports 2 data ports with speeds of 300 bps to 115.
Chapter 2 - Installation
MultiFRAD User Guide Introduction This chapter will guide you through the unpacking and installation of your MultiFRAD. The installation procedure, which is preceded by important safety warnings, provides step-by-step instructions on cabling and powering-on the MultiFRAD. Chapter 3 provides instructions on installing and configuring the MultiFRAD software. Safety Warning Telecom 1. Never install phone wiring during a lightning storm. 2.
Chapter 2 - Installation Unpacking your MultiFRAD Remove all items from the box. Your shipping box should contain the MultiFRAD, a power supply, various cables, software and manual disks, and a MultiFRAD Quick Start Guide. Inspect all items (Figure 2-1) before proceeding with the installation. If any item appears to be damaged, do not power up the unit; contact Multi-Tech’s Technical Support personnel for advice (Refer to Chapter 6).
MultiFRAD User Guide Cabling your MultiFRAD Cabling your MultiFRAD involves making the proper Power, Command Port, Ethernet, and Channel (and Voice/Fax, FR221/V2 Only) connections. Figure 2-2 shows the back panel connectors and the associated cable connections. The MultiFRAD supports two data channels.
Chapter 2 - Installation 5 On the FR221/V2 only: if you are connecting your MultiFRAD to a station device; e.g., analog telephone, fax machine, or Key Telephone System (KTS); connect one of the supplied RJ-11 cables to the Voice/Fax Channel 1 FXS connector on the back of the MultiFRAD and the other end to the station device.
MultiFRAD User Guide V.35 Shunt Procedure If you are using an external link device on a data port (or the trunk port), and the connection will be a V.35 connection, the corresponding internal shunt must be moved from its default RS232C position prior to cabling and power-up. The following steps detail the procedures for switching the shunt. Step Procedure 1 Ensure that the external power supply is disconnected from the MultiFRAD.
Chapter 2 - Installation 5 Pry the shunt (TRUNK, CHANNEL 1, or CHANNEL 2) out of its default RS232 position; check that no pins are bent or missing, then insert the shunt in the corresponding V.35 position shown on Figure 2-5. Note: Markings are on main PCB assembly; shunts are shown in their default RS232 locations. RS232 V.35 V.35 V.35 RS232 RS232 CHANNEL 2 CHANNEL 1 TRUNK Back Panel Jacks, Connectors, and Switch Figure 2-5.
MultiFRAD User Guide E&M Jumper Block Positioning Procedure (FR221/V2 Only) Each voice/fax channel on the FR221/V2 has a separate E&M jumper block, located near the channel jacks on the back panel of the MultiFRAD. Each jumper block has 8 pairs of pins with a jumper plug on three adjacent pairs of pins. The E&M type numbers are labeled on the printed circuit board, and the jumper plug needs to be centered on the E&M type number corresponding to type of E&M connection used on that channel (1 or 2).
Chapter 3 - Software Loading and Configuration
MultiFRAD User Guide Installing Your Software The following procedure does not provide every screen or option used in the process of installing the MultiFRAD software. The assumption is that a technical person with a thorough knowledge of Windows and the software loading process is doing the installation. Additional information on the MultiFRAD software is provided in the User Guide supplied with your MultiFRAD. 1 Run Windows on the PC that is connected to the Command Port.
Chapter 3 - Software Loading and Configuration 7 After all the program files from both disks are loaded, the Setup dialog box is displayed, enabling you to designate the COM port of the PC that is connected to your MultiFRAD. On the Select Port field, click the down arrow and choose the COM port of your PC (COM1 -- COM4) that is connected to your MultiFRAD. Click OK to continue. 8 The Setup Complete screen is displayed. Click Finish to continue.
MultiFRAD User Guide 9 The following message is displayed: Click Yes to continue. 10 If your MultiFRAD is already turned on and fully booted, you may get the following message; if so, click Yes to continue.
Chapter 3 - Software Loading and Configuration Ethernet Setup 11 If your MultiFRAD is connected to an IPX network, continue with the following steps (12 thru 15). If your MultiFRAD is NOT connected to a LAN, click the IPX Routing Enable check box to disable IPX, then click OK and proceed to step 16 to disable IP protocol. 12 Router Name: You can either use the default Router Name (MultiFRAD 200) or assign a new Router Name in this field.
MultiFRAD User Guide 17 Record the IP address protocol information for your specific network in the space provided below: Ethernet IP Address ___.___.___.___ IP Address ___.___.___.___ Frame Type Mask ___.___.___.___ TYPE II/SNAP WAN Port Mask Remote Address ___.___.___.___ ___.___.___.___ 18 The default Ethernet IP Address has to be changed to your unique LAN address. Enter an acceptable, unique IP address for the Ethernet port.
Chapter 3 - Software Loading and Configuration WAN Port Setup 23 The WAN Port Setup dialog box is displayed. The defaults are as shown above: Frame Relay connection, Synchronous mode, with external clocking (DDS) from the phone system. Since the DSU connector on your MultiFRAD is cabled to a trunk connection of a frame relay network, click OK.
MultiFRAD User Guide Data Ports Setup 24 The Data Port Configuration dialog box enables you to individually configure the two data channels (Port 1 and Port 2) for PPP/Frame Relay, data over IP, or as a frame relay Hub. The Encapsulation Type group determines how the data channel is configured. If your MultiFRAD will be connected to a frame relay network or point-to-point, then accept the default PPP/Frame Relay option in the Encapsulation Type group.
Chapter 3 - Software Loading and Configuration DLCI Setup 28 If you enabled Frame Relay in the WAN Ports Default Setup dialog box, the Frame Relay DLCI Default Setup dialog box is displayed with all the groups inactive. Click OK to continue. Note: When your MultiFRAD is connected to an active frame relay network service, it can detect DLCIs and the frame relay management type. However, at this point your MultiFRAD is not yet communicating with the frame relay network.
MultiFRAD User Guide Voice/Fax Channel Setup 29 The Voice/Fax Channel setup dialog box is displayed. Its three tabs are used to define the voice/fax channel interface, voice coder, fax parameters, and regional phone parameters (tone pairs) for each channel. Configure each channel for the type of interface you are connecting to. The Interface tab defaults to Channel 1 in the Select Channel field. 30 The Interface group defaults to FXS (Loop Start).
Chapter 3 - Software Loading and Configuration 31 Repeat the above step to configure the interface type for voice/fax channel 2. To change the channel number, click the down arrow and highlight Channel 2. 32 When you are satisfied with your interface choices, and if the default voice coder is acceptable and your country/region is the default USA, then you can click OK and continue building your phone directory database. If you need to change the voice coder, click the Voice/Fax tab and proceed to step 34.
MultiFRAD User Guide Click OK to continue. 36 The Writing Setup dialog box is displayed as the setup configuration is written to the MultiFRAD. 37 After the setup is written to the MultiFRAD, the unit reboots. 38 Check that the BOOT LED on the MultiFRAD is Off after the download is complete. This may take several minutes as the MultiFRAD reboots. 39 Win3.1 users - you are returned to your Program Manager where the MultiFRAD 200 Program Group and Program Item (Windows icons) have been created.
Chapter 3 - Software Loading and Configuration Detect and Map Your DLCIs 40 To detect DLCIs and map your data ports and protocols to the detected DLCIs, perform the following steps: Win3.1 users - from the Program Manager, click the MultiFRAD Configuration icon in the MultiFRAD 200 Program Group. The main menu is displayed. Win95/98/NT users - from your desktop, click Programs | MultiFRAD 200 | MultiFRAD Configuration. The main menu is displayed. Click Frame Relay.
MultiFRAD User Guide 43 Click DLCI and the Frame Relay DLCI Setup dialog box is displayed. The Compression option may be useful at low link speeds (i.e., below 56K); however, do not use this feature with a high speed link (i.e., 56K or higher). Click to enable this option for each DLCI on which you want to use the compression function. 44 Click the DLCI you want to map. The Protocol Mappings, Port Mappings, and all the other groups become active.
Chapter 3 - Software Loading and Configuration Click OK. 53 The main menu is displayed. Build Your Phone Directory Database Perform the following steps to construct your phone directory database. 54 Click Phone Book on the main menu. The Phone Directory Database dialog box is displayed. You will build your personalized MultiFRAD Phone Directory in the following steps.
MultiFRAD User Guide In the Station Information group, enter a unique phone number for the destination voice/fax channel in the Phone Number field. For example, phone number 101. (This number does not have to be a standard number with 7 or more digits.) The Description field for the phone number is optional. In the following example, we describe this phone number as, “Jerry’s Desk.” The Voice Channel field defaults to Channel 1.
Chapter 3 - Software Loading and Configuration 57 Repeat steps 55 and 56 for each additional phone number. You should enter one phone number for each remote channel that you want to call. When you are finished, click OK. 58 You are returned to the main menu. Click Download Setup. 59 The “Save Current Setup” dialog box is displayed. Click the check box to retain the current setup as the User Default Configuration, then click OK.
MultiFRAD User Guide 38
Chapter 4 - MultiFRAD Software
MultiFRAD User Guide Introduction This chapter describes various features of the MultiFRAD software that enable you to change (update) the configuration of your MultiFRAD. The basic configuration parameters were established during the loading of the software (Chapter 3). The MultiFRAD software and configuration utilities described in this chapter enable you to change that initial configuration as necessary. The primary interface to the MultiFRAD software is a main menu (with MultiFRAD v3.
Chapter 4 - MultiFRAD Software MultiFRAD Configuration To view or change your MultiFRAD configuration in Windows 95/NT, click Start | Programs | MultiFRAD 200 | MultiFRAD Configuration, or double-click the MultiFRAD Configuration icon in the MultiFRAD 200 program group. After loading, the MultiFRAD main menu will appear. The MultiFRAD main menu consists of 12 buttons in which you can point and click, an Events window, and a status bar.
MultiFRAD User Guide Changing IP Parameters The IP Setup dialog box enables you change the IP routing capabilities, add or delete logical WANs, enable the DHCP relay agent, assign DNS server addresses, and define static routes and a default route. The initial routing capabilities were established during the software installation. You can change IP routing parameters by clicking on the Advanced tab and changing, for example, the RIP Response Time or RIP Route Aging Time.
Chapter 4 - MultiFRAD Software The Advanced tab on the IP Setup dialog box controls the timers, Dynamic Host Configuration Protocol (DHCP) and Domain Name System (DNS) options, the default route, filters, and Static Routes. In most cases, you should not have to change the value of any timer (default TTL, reassembly time-out, RIP response time, or RIP route aging time). If you are using Default Routing, disable RIP based routing, then enter the IP host address of the “next hop.
MultiFRAD User Guide Changing IPX Parameters The IPX Setup dialog box controls the four frame types and the WAN ports. The Advanced tab enables IPX routing, enables auto learn of Ethernet network numbers, and specifies the distributed name of the MultiFRAD. The RIP and SAP default timers should not have to be changed for most applications. Disabling IPX and SPX Watchdog Spoofing in the Bandwidth Optimization group has proven effective under certain circumstances with Citrix clients.
Chapter 4 - MultiFRAD Software The IPX WAN network number has to be the same on both ends of the link and must be unique throughout the internetwork. If the WAN port is configured in a point-to-point operation, both WAN network numbers have to be the same and unique. If the WAN port is configured for frame relay, both logical WAN network numbers have to be the same and unique.
MultiFRAD User Guide Spanning Tree Setup When the Bridging Enable option is enabled, the Spanning Tree Setup dialog box controls transparent bridging; however, if there are any loops or redundant links in the internetwork, the Spanning Tree Algorithm Enable option must also be enabled. Spanning Tree is a method of transparent bridging, as opposed to source route bridging which the MultiFRAD does not support. The MultiFRAD defaults with one logical WAN port mapped to a DLCI.
Chapter 4 - MultiFRAD Software Statistics The Statistics dialog box enables you to view statistics on the major events of the MultiFRAD. The Statistics dialog box changes depending on the way the WAN port is configured. If the MultiFRAD is configured for point-to-point operation, the button to the right of the WAN button changes from “Frame Relay” to “PPP” and the DLCI button will no longer be active.
MultiFRAD User Guide IP Statistics IP is a connection-less network protocol that resides in the network layer of a conventional OSI layered model (for more information on this model, refer to Appendix C). Depending on what is going on at the application layer, IP will typically use one of two transport layer protocols.
Chapter 4 - MultiFRAD Software IPX Port Statistics The IPX Port Statistics dialog box displays information pertaining to the IPX Port; for example, the frame type used or the number of packets transmitted/received. IPX is a network layer protocol usually associated with Novell NetwareTM networks. It allows for encapsulation of four different frame types over a single physical LAN connection (provided each frame type has a unique network address): RAW (802.3), LLC (802.2), Ethernet II, and SNAP.
MultiFRAD User Guide SNMP Statistics The SNMP Statistics dialog box provides statistical information on Simple Network Management Protocol (SNMP). SNMP is an application layer protocol that facilitates the exchange of management information between network devices. There are three key components in SNMP: the devices that are to be managed, agents, and the network management systems. The managed device is the network device, such as a router.
Chapter 4 - MultiFRAD Software Frame Relay Statistics The Frame Relay Management Statistics dialog box can be a useful tool for troubleshooting MultiFRAD installations and monitoring the performance of active links, and checking that the MultiFRAD is talking to the provider’s switch. The Polling Details section lists the various management frames sent and received. For every Status Enquiry Sent, a Status Response should be received from the network.
MultiFRAD User Guide When troubleshooting a frame relay circuit, once it has been established that management frames are being sent and received, the next step is to determine whether the DLCIs are becoming active. This dialog box will provide that information. A FRAD needs to be present at both ends for the DLCI to be active. Keep in mind that the frame relay network tells the FRAD the status of the PVC with one of its status responses.
Chapter 4 - MultiFRAD Software These statistics may indicate that either the data channels, or more likely the devices attached to them, are being driven harder than they should be. Excessive buffer utilization and/or receive flow control time can usually be reduced or eliminated by slowing the speed at which the channel is operating.
MultiFRAD User Guide Call Progress Statistics (FR221/V2 Only) The Call Progress Statistics dialog box displays statistical information for the current activity, such as a call in progress. A drop-down list enables you to select which channel you want to monitor. After a channel is selected, all the relevant data for the current activity on that channel will be displayed in the fields provided. Note: the Packets Sent and Bytes Sent are for the local side of the current call.
Chapter 4 - MultiFRAD Software WAN Port Setup The WAN Port Setup dialog box selects whether the DSU port is enabled or not and controls how this port is configured (i.e., for frame relay or for point-to-point operation). For Frame Relay operation, you can ignore everything in the Mode and Connection Method groups on this dialog box. For point-topoint operation, the FR221/V2 voice/fax channels are not operational.
MultiFRAD User Guide Point-To-Point You can check communication between two MultiFRADs by cabling their DSU ports together with an RJ-45 cable, selecting point-to-point operation (PPP/SLIP), enabling DSU Loop Back, and setting one MultiFRAD to Internal Clocking and the other one to DDS. Data applied to the DSUs will be reflected both ways. Further configuration for point-to-point operation can be set up by clicking the PPP button on the main menu.
Chapter 4 - MultiFRAD Software Point to Point Setup The Point to Point Setup dialog box controls the WAN port protocol, dial on demand, and remote port setup. The WAN port protocol can be either Point to Point Protocol (PPP) or Serial Line Internet Protocol (SLIP). PPP is the more robust of the two protocols in that it enables the endpoints to negotiate use of the link and protocol parameters in a standardized way and also provides for standardized encapsulation of the packets.
MultiFRAD User Guide Frame Relay Setup The Frame Relay dialog box displays the CIR Measurement Interval in milliseconds, the Management Type and details of that management type, and the number of DLCI’s that are active. The MultiFRAD can detect DLCIs and the Management Type when you are connected to an active frame relay service. So it is important that if you change any frame relay parameters, that the new parameters agree with the way your frame relay service is provisioned.
Chapter 4 - MultiFRAD Software If you are connected to a frame relay service, this dialog box should display your current DLCI numbers automatically. It also shows the protocol mapping of the highlighted DLCI, which data ports are mapped to it, and how you set up your Congestion Management, Mode, CIR, and Be values. To change the mapping of a DLCI, highlight the DLCI number in the list on the left side of the dialog box. The dialog box will then change to the mapping of that DLCI.
MultiFRAD User Guide Congestion Management, Mode, and CIR/Be settings are used to avoid congestion and possible loss of data. The Committed Information Rate (CIR) and Excess Burst rate (Be) settings are throughput amounts determined by the network and user when each DLCI is ordered. The CIR is the basic throughput which the network will try to set aside for that DLCI. It will always be equal to or less than the actual access rate of the physical line (i.e.
Chapter 4 - MultiFRAD Software When you click the OK button in the IP WAN dialog box, you now have an IP address for a second logical WAN. Now we have to tie that IP address to a DLCI, which in our example is DLCI 17. Now, return to the Frame Relay DLCI dialog box and highlight DLCI 17. Click the Protocol Mappings Map IP Address down arrow and the IP address 192.168.2.1 appears. Click this address and now IP address 192.168.2.1 is mapped to DLCI 17. We now have WAN IP address 192.168.2.
MultiFRAD User Guide Packet Priority Three levels of priority (High, Medium, and Low) are supported for data packets (i.e., IP packets, IPX packets, and STP packets), whether in frame relay or point-to-point mode. When priority levels are in use, the packets are processed based on their priority setup.
Chapter 4 - MultiFRAD Software Data Port Configuration This dialog box lets you leave both data ports enabled for normal data transfer operations or disable a given port if you do not want to transmit or receive data over it. The Destination Port parameter will be active only if both data ports have been mapped to the same DLCI. For point-to-point operation, only APSM mode will be enabled. For frame relay operation, APSM mode allows both data ports and any protocol stacks to be mapped to a single DLCI.
MultiFRAD User Guide Changing Channel Parameters (FR221/V2 only) Click the Voice Channels button on the main menu to display the Voice/Fax Channel Setup dialog box. The Interface tab is the default tab that appears whenever this dialog box is opened. The other two tabs contain voice and fax settings and the voice communications Tone Pairs for the MultiFRAD. Interface The Interface tab defines the interface type used on each voice/fax channel.
Chapter 4 - MultiFRAD Software The Max Dial Digits field in the Dialing Options group indicates the longest phone number you can enter in the phone directory database. The value shown in this field is the maximum number of digits permitted in any phone number entered into the database. It does not represent an actual phone number. The range for the Maximum Dial Digits is 1 to 16 digits, and the default is 5 digits.
MultiFRAD User Guide Voice/Fax (FR221/V2 only) The Voice/Fax tab controls the voice coder, Fax settings, DTMF gain, and some miscellaneous options. The MultiFRAD supports numerous state-of-the art ITU (International Telecommunications Union) voice coders. The Voice Coder drop-down menu enables you to select from a range of coders with specific bandwidths. The higher the bps rate, the more bandwidth is used.
Chapter 5 - Remote Configuration and Management Regional (FR221/V2 only) The Regional tab controls the voice communications for the country or region in which the MultiFRAD is being used. From the Country/Region drop-down list you can select the country or region for which you are configuring the MultiFRAD. The Tone Pairs group always displays the tones used in the country or region currently selected.
MultiFRAD User Guide Changing the Phone Directory Database (FR221/V2 only) Clicking the Phone Book button on the main menu displays the Phone Directory Database dialog box, which displays the phone numbers of all the MultiFRADs in your network. The Station Phone Number field on this dialog box lists the phone numbers in numerical order.
Chapter 4 - MultiFRAD Software The Edit button on the Phone Directory Database dialog box enables you to edit any existing phone number in the database. Clicking the selected number, then clicking the Edit button displays the Edit Phone Entry dialog box where you can change the information in any field(s), permit hunting, or enable routing.
MultiFRAD User Guide Others Setup Clicking the Others button on the main menu displays the Others Setup dialog box. This dialog box lets you to enable SNMP Agent (the default is disabled) and set up all the necessary parameters; enable or disable various remote configuration methods such as TFTP (Trivial File Transfer Protocol) Server, Web Server, Dumb Terminal, and Telnet Server; and assign a Password to the MultiFRAD for Internet security.
Chapter 4 - MultiFRAD Software Enable Logging of Statistics Clicking the Log Setup button on the Others Setup dialog box displays the Log Statistics dialog box which lets you Enable/Disable Logging, set the time interval (in minutes) between logging, and either Log all Statistics or only those statistics that you enable (check) on this dialog box. You can also select specific port data or DLCI data for logging by clicking the appropriate button(s).
MultiFRAD User Guide Enable Analysis of Statistics Clicking the Analysis Setup button on the Others Setup dialog box displays the Log Statistics dialog box. This dialog box lets you set the Start/Stop parameters (the start date/time and end date/ time) for statistics logging, and enable Analyze All or analyze only certain statistics that you enable (check) on this dialog box.
Chapter 5 - Remote Configuration and Management
MultiFRAD User Guide Introduction This chapter provides procedures for viewing or changing the configuration of a remote unit. Two methods are provided to access a remote unit; the first method is modem based and the second method is using IP. Within the IP method, three applications can be used: 1) LAN-Based using TFTP (Trivial lFile Transfer Protocol), 2) Telnet as a client application, or 3) a standard Web browser on the Internet.
Chapter 5 - Remote Configuration and Management Verify that the Communication Type is set for COM Port and the Select Port field is set for the COM port of your local PC. In the Dial String field, enter the AT command for dialing (ATDT) plus the phone number of the remote MultiFRAD.
MultiFRAD User Guide LAN-Based The LAN-based remote configuration requires a Windows Sockets compliant TCP/IP stack. TCP/IP protocol software must be installed and functional before the configuration program can be used. 1 You must assign an Internet (IP) address for the PC and for each node that will be managed by the configuration program. Refer to the protocol software documentation for instructions on how to set the IP addresses.
Chapter 5 - Remote Configuration and Management Remote Management This section describes typical client applications that can be used to configure the MultiFRAD remotely. It is important to note that although any subsequent changes to configuration can be made using these applications, the initial setup and configuration of the MultiFRAD must be done using a local PC and the MultiFRAD software provided with your unit.
MultiFRAD User Guide MultiFRAD Configuration (Main Menu) Selecting Option 1 displays the MultiFRAD Configuration Main Menu, which enables you to view and change parameters on the protocol stacks, high and low level device drivers, enable or disable the supported servers, configure MUX data ports, set up filtering and priority, or view system information. Also, for the “/V2” version only, you can configure voice/fax channels 1 and 2, set up ‘Regional parameters, and build or edit the Phone Book Database.
Chapter 5 - Remote Configuration and Management Web Browser Management The MultiFRAD can be accessed, via a standard Web browser, from anywhere on the connected Internet. In order to provide this support, the WEB Server option has to be enabled from the Others button on the main menu which displays the Others Setup dialog box (see Chapter 4 - MultiFRAD Software).
MultiFRAD User Guide 80
Chapter 6 - Warranty, Service and Tech Support
MultiFRAD User Guide Introduction This chapter will provide you the resources for receiving service or support for your MultiFRAD. The chapter starts with a description of the warranty, and continues with instructions for contacting the Service department, Technical Support group, and various Multi-Tech Internet resources. Limited Warranty Multi-Tech Systems, Inc.
Chapter 6 - Warranty, Service and Tech Support Tech Support Multi-Tech has an excellent staff of technical support personnel available to help you get the most out of your Multi-Tech product. If you have any questions about the operation of this unit, call 1-800-9722439. Please fill out the MultiFRAD information (below), and have it available when you call. If your MultiFRAD requires service, the tech support specialist will guide you on how to send in your equipment (refer to the next section).
MultiFRAD User Guide Service If your tech support specialist decides that service is required, your MultiFRAD may be sent (freight prepaid) to our factory. Return shipping charges will be paid by Multi-Tech Systems. Include the following with your MultiFRAD: • a description of the problem. • return billing and return shipping addresses. • contact name and phone number. • check or purchase order number for payment if the MultiFRAD is out of warranty.
Chapter 6 - Warranty, Service and Tech Support The Multi-Tech BBS For customers who do not have Internet access, Multi-Tech maintains a bulletin board system (BBS) that mirrors its FTP site. Information available from the BBS includes new product information, product upgrade files, and problem-solving tips. The phone number for the Multi-Tech BBS is (800) 392-2432 (USA and Canada) or (612) 785-3702 (international and local).
MultiFRAD User Guide About the Internet If you prefer to receive technical support via the Internet, you can contact Tech Support via e-mail at the following address: http://www.multitech.com/_forms/email_tech_support.htm Multi-Tech’s presence includes a Web site at: http://www.multitech.com and an ftp site at: ftp://ftp.multitech.com The ftp server mirrors the Multi-Tech BBS.
Appendixes
MultiFRAD User Guide Appendix A - Cabling Diagrams Command Port Cable RS232 12345678 COMMAND To COMMAND PORT Connector RJ-45 DB9F PIN NO. PIN NO. 1 4 2 7 TRANSMIT DATA 3 8 RECEIVE DATA 4 3 To DTE Device 5 2 (e.g.
Appendix A - Cabling Diagrams Voice/Fax Channel Connectors 1 2 3 4 5 6 7 8 2 3 4 5 2 3 4 5 Pin Connections E&M 1 2 3 4 5 Description M E T1 R T FXO Description FXS Description 2 3 4 5 N/C Ring Tip N/C 2 3 4 5 N/C Tip Ring N/C 89
MultiFRAD User Guide Trunk Cable 13 25 12 11 24 10 23 9 22 8 21 20 7 6 19 5 18 4 17 3 16 2 15 1 14 TRUNK (RS232/V.35) RS232C/V.24 * Link Cable PIN NO. To External Synchronous Modem/DSU Connector PIN NO. 1 1 2 2 3 3 4 4 5 5 7 7 8 8 15 15 17 17 20 20 25 25 CHASSIS GROUND (AA) TRANSMIT DATA (BA) RECEIVE DATA (BB) REQUEST TO SEND (CA) CLEAR TO SEND (CB) SIGNAL GROUND (AB) To MultiFRAD TRUNK (RS232C/V.
Appendix B - Regulatory Information Appendix B - Regulatory Information Class A Statement FCC Part 15 NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
MultiFRAD User Guide FCC Part 68 Telecom 1. This equipment complies with Part 68 of the Federal Communications Commission (FCC) rules. On the outside surface of this equipment is a label that contains, among other information, the FCC registration number. This information must be provided to the telephone company. 2. As indicated below, the suitable jack (Universal Service Order Code connecting arrangement) for this equipment is shown.
Appendix C - Network Overview Canadian Limitations Notice Ringer Equivalence Number Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a phone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5.
MultiFRAD User Guide Appendix C - Network Overview Network architecture defines how computer equipment and other devices are linked together to form a communications system that enables users to share information and resources. There are proprietary network architectures and open architectures like the Open Systems Interconnection (OSI) model defined by the International Organization for Standardization (IOS).
Appendix C - Network Overview including more sophisticated error handling, prioritization, and security features. It provides quality service and accurate delivery by providing connection-oriented services between two end systems. The transport layer controls the sequence of packets, regulates traffic flow, and recognizes duplicate packets. It assigns packetized information which is a tracking number that is checked at the destination.
MultiFRAD User Guide different destination address, and in some cases, different sizes. A typical packet holds 512 bytes of information, so it takes many packets to transfer a large file over a network. As packets traverse a network, the addressing information contained in them is used by bridges and routers to direct packets to their destination, or keep them off of networks where they don't belong.
Appendix C - Network Overview IP Addressing Every node on an IP network requires a 4-byte numeric address that identifies both a network and a local host or node on the network. This address is written as four numbers separated by dots, for example, 148.1.9.1. In most cases, the network administrator sets up these addresses when installing a device.
MultiFRAD User Guide Appendix D - Disabling the Internal DSU Perform the following procedure if your WAN network has been upgraded to T1/E1 and you now want to disable the MultiFRAD’s internal DSU and use the back panel Trunk connection to obtain data rates of up to 2.048 Mbps. 1 Turn off the MultiFRAD using the back panel Power switch. 2 Locate the access window (side slot opening) near the left front corner of the MultiFRAD.
Glossary
MultiFRAD User Guide A Access: The T1 line element made up of two pairs of wire that the telephone company brings to the customer premises. The Access portion ends with a connection at the local telco (LEC or RBOC). Accunet Spectrum of Digital Services (ASDS): The AT&T 56K bps leased (private) line service. Similar to services of MCI and Sprint. ASDS is available in nx56/64K bps, where n=1, 2, 4, 6, 8, 12.
Glossary Basic Rate Interface (BRI): An ISDN access interface type comprised of two B-channels each at 64K bps and one D-channel at 64K bps (2B+D). Bell Operating Companies (BOC): The family of corporations created during the divestiture of AT&T. BOCs are independent companies which service a specific region of the US. Also called Regional Bell Operating Companies (RBOCs).
MultiFRAD User Guide Channel bank: A device that acts as a converter, taking the digital signal from the T1 line into a phone system and converting it to the analog signals used by the phone system. A channel bank acts as a multiplexer, placing many slow-speed voice or data transactions on a single high-speed link. Circuit-switched Network: A technology used by the PSTN that allocates a pair of conductors for the exclusive use of one communication path.
Glossary Device driver: Software that controls how a computer communicates with a device, such as a printer or mouse. Digital Cross-connect System (DCS): The CO device which splits and redistributes the T1 bandwidth. The DCS takes time slots from various T1 lines and alters them to provide the needed connectivity. DCS connections are made with software at an administrator's workstation. Digital Data: Information represented by discrete values or conditions (contrast "Analog Data").
MultiFRAD User Guide Exchange Termination (ET): The carrier's local exchange switch. Contrast with "Loop Termination - LT". Explicit Congestion Management: The method used in frame relay to notify the terminal equipment that the network is overly busy. The use of FECN and BECN is called explicit congestion management. Some end-to-end protocols use FECN or BECN, but usually not both options together. With this method, a congestion condition is identified and fixed before it becomes critical.
Glossary Graphical User Interface (GUI): A type of computer interface consisting of a visual metaphor of a real-world scene, often of a desktop. Within that scene are icons, representing actual objects, that the user can access and manipulate with a pointing device. H Handshaking: A process that two modems go through at the time of call setup to establish synchronization over the data communications link.
MultiFRAD User Guide L LAPB: Link Access Procedure Balanced; based on the X.25 Layer 2 specification. A full-duplex point-to-point bit-synchronous protocol commonly used as a data link control protocol to interface X.25 DTEs. LAPB is the link initialization procedure that establishes and maintains communications between the DTE and the DCE. LAPD: Link Access Protocol for the D-Channel; based on the ISDN Q.921 specification.
Glossary Multiprotocol: A device that can interoperate with devices utilizing different network protocols. Multithreading: The ability of a software system to be able to handle more than one transaction concurrently. This is contrasted to the case where a single transaction is accepted and completely processed before the next transaction processing is started. N Nailed Connection: A permanent or dedicated circuit of a previously switched circuit or circuits.
MultiFRAD User Guide Point of Presence (POP): The central office's end points of the long distance carriers. Point to Point Protocol (PPP): A protocol that lets a PC user access TCP/IP (Internet member) using an ISDN terminal adapter or a high-speed modem over a standard telephone line. Port: A location for input or output data exchange. Computers, muxes, etc. have ports for various purposes. Primary Rate Interface (PRI): Used on ISDN.
Glossary Robbed Bit Signaling: The popular T1 signaling mechanism where the A and B bits are sent by each side of the T1 termination and are "buried" in the voice data of each voice channel in the T1 circuit. Since the bits are "robbed" infrequently, voice quality is remains relatively uncompromised. See "bit robbing". The robbed-bit signaling technique is used in D4 channel banks to convey signaling information.
MultiFRAD User Guide Synchronous Transmission: The transmission of data which involves sending a group of characters in a packet. This is a common method of transmission between computers on a network or between modems. One or more synchronous characters are transmitted to confirm clocking before each packet of data is transmitted. Compare to Asynchronous Transmission.
Glossary Transport Layer: Layer 4 of the Open Systems Interconnection (OSI) model; provides reliable, end-to-end delivery of data, and detects transmission sequential errors. Transport Protocol Data Unit (TPDU): A transport header, which is added to every message, contains destination and source addressing information that enables the end-to-end routing of messages in multi-layer NAC networks of high complexity.
MultiFRAD II User Guide Index G Glossary .............................................................. 99 A I About the Internet ................................................ 86 ASCII String ......................................................... 25 Indicators Channels Clear To Send (CTS) ...................................... 8 Receive (RCV) ............................................... 8 Transmit (XMT) .............................................. 8 V35 (V35) ...............................
Index Power Connector ................................................. 10 Proxy Server Configuration ................................. 79 ProxyServer Software ......................................... 40 R Recording MultiFRAD Information ....................... 83 Regulatory Information ........................................ 91 Remote Address .................................................. 26 Remote Configuration LAN-Based Procedure ..................................... 76 Remote Management ........