Specifications
Chapter 1 – AT Commands, S-Registers and Result Codes 
Multi-Tech Systems, Inc. SocketModem MT5600SMI/MT5656SMI Reference Guide (S000306B)  31 
    +ES=3  Enable V.42 with Detection Phase originator. Disable V.80 
Synchronous Access Mode originator. 
    +ES=,,2  Allow LAPM, MNP, or Normal Mode connection answerer. 
Disable V.80 Synchronous Access Mode answerer. 
    +ES=3,,2  Enable V.42 with Detection Phase originator, allow LAPM, 
MNP, or Normal Mode connection answer. Disable 
Synchronous Access Mode originator and answerer.     
Report Commands:  +ES?  Reports the current values 
      Response: +ES: <orig_rqst>,<orig_fbk>,<ans_fbk> 
      Example: +ES: 3,0,2 For the default setting.     
    +ES=?  Reports supported range of parameter values 
  Response: +ES: (<orig_rqst> range),( <orig_fbk> range), 
(<ans_fbk> range) 
      Example: +ES: (0-4,6,7),(0-4),(0-6,8,9) 
Command:  +EB  Break Handling in Error Control Operation 
Description:  This extended-format compound parameter controls the break handling in 
V.42 operation. It accepts three numeric subparameters: 
Default:  None 
Defined Values:   <break_selection>  Decimal number 0 specifying that break is to be 
ignored, i.e., not signaled to remote DCE. 
    <timed>  Decimal number 0 specifying that any transmitted 
V.42 L-SIGNAL will not indicate break signal length 
<default_length>  Decimal number 0 specifying that break is not 
delivered to the DTE. 
Report Commands:   +EB?  Reports current or selected values    
  Response: +EB: 
<break_selection>,<timed>,<default_length><CR> 
      Example: +EB: 0,0,0 For default settings. 
    +EB=?  Reports supported range of parameter values 
      Response: +EB: (<break_selection> range),(<timed> range), 
(default_length> range) 
    Example: +EB: (0),(0),(0) 
Command: +ESR  Selective Reject 
Description:  This extended-format numeric parameter controls the use of the selective 
reject (SREJ) option in V.42. 
    Decimal number 0 specifying that SREJ is not used. 
Report Commands:  +ESR?  Reports Current or Selected Values: 
      Response: +ESR: <value> 
      Example: +ESR: 0 For default setting 
    +ESR=?  Reports Supported Range of Parameter Values 
      Response: +ESR: (<value>) 
  Example: +ESR: (0) 
Command:  +EFCS  32-bit Frame Check Sequence 
Description:    This extended-format numeric parameter controls the use of the 16-bit or 
32-bit frame check sequence (FCS) option in V.42. 
Defined Values:   <value> Decimal number 0 specifying the use of the 16-bit FCS specified 
in V.42. 
Report Commands:  +EFCS?  Current or Selected Values: 
        Response: +EFCS: <value> 
      Example: +EFCS: 0 For default setting. 
  +EFCS=?  Reporting Supported Range of Parameter Values     
      Response: +EFCS: (<value> range) 
      Example: +EFCS: (0) 