Specifications
    Chapter 3 – Fax Class 2 Commands 
Multi-Tech Systems, Inc. SocketModem MT5600SMI/MT5656SMI Reference Guide (S000306B)  86 
Phase C Data Framing 
Phase C data may be presented to the DTE in stream mode. The DCE will transfer a stream of data to 
the DTE, followed by the <DLE><ETX> stream termination characters. 
The DCE will filter the stream as described in Voice Commands -- <DLE> Shielded Codes Sent to the 
Modem (DCE). 
Phase C Data Format 
The received data format is negotiated under T.30 reported by the +FDCS:VR,BR,WD,LN,DF,EC,BF,ST 
response. 
The DCE will delete the terminating RTC (6 EOLs) patterns. 
<CAN> - Escape from Reception 
From the +FDR command until the end of Phase D Date, the DCE is in a data transfer state, and will not 
respond to DTE command characters. The DCE will respond to three ASCII control characters: <DC1> 
(017) and <DC3> (019) flow control characters, and cancel <CAN> (024). 
Upon receipt of the <CAN> character, the DCE will terminate the reporting of received data by sending 
trailing <DLE><ETX> characters to the DTE, and will then execute an implied +FK command in order to 
conduct an orderly disconnection. 
Command:   +FK  Session Termination 
Description:    The +FK command causes the DCE to terminate the session in an orderly 
manner. In particular, the DCE will send a DCN message at the next 
opportunity and hang up. At the end of the termination process, the DCE will 
report the +FHNG response with result code. 
    This operation can be invoked by using the cancel <CAN> character during 
Phase C data reception (see prior section). 
    The DCE will wait until the current page completes, unless the reception is of 
unlimited length; in that case, the DCE may halt reception and terminate the 
session at any time. 
Syntax:    +FK 
Command:  +FCIG  Set Polling ID 
Description:    This command allows setting the Local Polling ID string used in a CIG frame. 
The syntax of this command is identical to +FLID. 
Write syntax:    +FCIG="<local ID string>" 
Valid value:    20-character ASCII string 
Default value:    Empty 
Command:  +FLPL  Indicate a Document for Polling 
Description:    This command allows setting up an answering modem to know that it has a 
document available for polling. This allows a calling modem to receive this fax 
from the answerer. 
Syntax:  AT+FLPL=? 
 0,1 
 OK 
 AT+FLPL=1 
 OK 
 AT+FLPL? 
 1 