Universal Socket Connectivity For Embedded Modems SocketModem – MT5600SMI SocketModem – MT5656SMI SocketModem – MT5634SMI SocketModem – MT2456SMI-22 SocketModem IP – MT2456SMI-IP SocketEthernet IP – MTXCSEM SocketModem ISDN – MT128SMI SocketModem GPRS – MTSMC-G SocketModem CDMA – MTSMC-C SocketWireless Bluetooth® – MTS2BTSMI Hardware Guide for Developers
Copyright and Technical Support Universal Socket Connectivity Developer's Guide PN S000342C, Version C Copyright This publication may not be reproduced, in whole or in part, without prior expressed written permission from MultiTech Systems, Inc. All rights reserved. Copyright © 2004 by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc.
Table of Contents Table of Contents Chapter 1 - Universal Socket Connectivity ................................................................................................................8 Multi-Tech Embedded Solutions .............................................................................................................................8 Universal Socket Connectivity Features .................................................................................................................
Table of Contents Parallel Host Bus Timing Table.............................................................................................................................48 SocketModem Parallel Interface ...........................................................................................................................49 Overview........................................................................................................................................................
Table of Contents Chapter 4 – SocketModem (MT2456SMI-22) ............................................................................................................80 Introduction ...........................................................................................................................................................80 Product Ordering Information................................................................................................................................
Table of Contents Chapter 8 – SocketModem GPRS (MTSMC-G)....................................................................................................... 112 Product Description............................................................................................................................................. 112 Product Ordering Information.............................................................................................................................. 112 Developer Kit .........
Chapter 1 Universal Socket Connectivity Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Chapter 1 - Universal Socket Connectivity Multi-Tech Embedded Solutions Multi-Tech’s family of embedded solutions creates communication-ready devices by integrating data/fax or Internet functionality into a single, universal socket design. Now you have the ability to provide remote monitoring, diagnostics, data collection, or virtually any communication ability to your existing or new device via interchangeable dial-up, wireless, or Ethernet communication modules.
Chapter 1 – Universal Socket Connectivity AT Commands, Fax Commands, and Voice Commands AT Commands Multi-Tech provides Reference Guides for each SocketModem's AT commands, fax commands, and voice commands. These reference guides are available on the CD included in the Developer Kit. They are also available by email at oemsales@multitech.com or by request using the Developer Guide Request Form on Multi-Tech's Web site.
Chapter 1 – Universal Socket Connectivity Universal Socket Configuration Universal Pin Descriptions 1 Signal Name Tip I/O Type I/O 2 Ring I/O 3 4 Safety Void NA TX+ O 5 TX- O 6 RX+ I 7 RX- I 8 11 12 22 23 Safety Void TCLK RCLK MIC+ MIC- NA O O I O Pin Description Tip Signal from Telco. Tip connection to the phone line (RJ-11 Pin 4). The SocketModem is Tip/Ring polarity insensitive. Ring Signal from Telco. Ring connection to the phone line (RJ-11 Pin 3).
Chapter 1 – Universal Socket Connectivity 24 Signal Name –RESET 26 29 GND LED DCD 30 LED RX 31 LED DTR 32 LED TX 33 –RTS 34 –RXD 35 –TXD 36 –RI or PIO5 37 –DSR or PIO7 Pin I/O Description Type Device Reset (with pull-up). I The active low –RESET input resets the device logic and returns the configuration of the device to the original factory default values of "stored values" in the NVRAM. –RESET is tied to VCC through a time-constant circuit for “Power-on-Reset” functionality.
Chapter 1 – Universal Socket Connectivity 38 Signal Name –CTS I/O Type O 39 –DCD O 40 –DTR or PIO6 I 41 42 43 56 GND SPKSPK+ –LED FDX GND O/O O/I O 57 –LED ACT O 58 –LEDLINK O 59 –LEDCOL O 60 –LEDSPD O 61 62 VCC MICV PWR I/O 63 AGND GND 64 SPKR O Pin Description Clear to Send (Active Low). –CTS is controlled by the module to indicate whether or not the module is ready to transmit data. –CTS ON indicates to the DTE that signals on TXD will be transmitted.
Chapter 1 – Universal Socket Connectivity Design Considerations Good engineering practices must be adhered to when designing a printed circuit board (PCB) containing the SocketModem module. Suppression of noise is essential to the proper operation and performance of the modem itself and for surrounding equipment. Two aspects of noise in an OEM board design containing the SocketModem must be considered: on-board/off-board generated noise that can affect digital signal processing.
Chapter 1 – Universal Socket Connectivity Electromagnetic Interference (EMI) Considerations The following guidelines are offered to specifically help minimize EMI generation. Some of these guidelines are the same as, or similar to, the general guidelines but are mentioned again to reinforce their importance. In order to minimize the contribution of the SocketModem-based design to EMI, the designer must understand the major sources of EMI and how to reduce them to acceptable levels. 1.
Chapter 1 – Universal Socket Connectivity Mechanical Dimensions in Inches Note: This tooling hole is not on all models. 64 63 62 61 60 59 58 57 56 55 54 1 2 3 4 5 6 7 8 9 10 11 53 12 52 13 51 14 50 15 49 16 48 17 47 18 46 19 45 20 44 21 43 22 42 23 41 24 40 25 39 26 38 27 37 28 36 29 35 30 34 31 33 32 Dimensions Are Shown in Inches Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Mechanical Dimensions in Millimeters Dimensions Are Shown in Millimeters Maximum Component Height Product Measurement from top of board to highest topside component Measurement from bottom of board to lowest bottom-side component SocketModem – MT5600SM SocketModem – MT5656SMI .110 inches (2.80 mm) .212 inches (5.38 mm) .290 inches (7.36 mm) .212 inches (5.38 mm) .228 inches (5.79 mm) .315 inches (8.00 mm) .153 inches (3.88 mm) .238 inches (6.04 mm) .
Chapter 1 – Universal Socket Connectivity SocketModem Developer Board SocketModem Developer Board Layout This theoretical developer board drawing shows the major board components for all SocketModems. Note that the board shipped in the Developer Kit is designed and built with only the components required by the SocketModem in that kit; e.g., a serial dialup SocketModem board will not contain components for a wireless SocketModem. 5 V / 3.3 V Jumper – JP6 The operating voltage factory default setting is 3.
Chapter 1 – Universal Socket Connectivity SocketModem Developer Board Schematics Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Telecom Approvals Multi-Tech's Analog Dial-up Global* SocketModems are designed and approved for connection to the public switched telephone network in more than 50 countries or regions worldwide. Multi-Tech's SocketModems have been approved as host independent, which means our certification efforts can be transferred directly to your end product.
Chapter 1 – Universal Socket Connectivity United States Labeling Requirements Note: Telecom does not apply to all products. For example, this not applicable for the Wireless GSM/GPRS and CDMA products.
Chapter 1 – Universal Socket Connectivity Canadian Labeling Requirements The following requirements are established under section 69.3 of the Telecommunications Act for purposes of section 5 of the Telecommunications Apparatus Regulations.
Chapter 1 – Universal Socket Connectivity • • “XXXXXX” is the Company Number, as in (d) above; and “ZZZZZZZZ” is either the old certification number minus the old company number, or a new Unique Product Number assigned by the applicant. For example, if a new model is registered to the family of products with certification number “123 1234 A”, and that the Company Number for the registration is “123A”, then the self-mark for this new model would read “IC: 123A-1234 A”.
Chapter 1 – Universal Socket Connectivity Regulatory Compliance Statements EMC, Safety, and R&TTE Directive Compliance The CE mark is affixed to this product to confirm compliance with the following European Community Directives: Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility; and Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed f
Chapter 1 – Universal Socket Connectivity New Zealand Telecom Warning Notice 1. 2. 3. 4. 5. 6. 7. 8. The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with minimum conditions for connection to its network. It indicates no endorsement of the product by Telecom, nor does it provide any sort of warranty.
Chapter 1 – Universal Socket Connectivity Flash Upgrade Your modem is controlled by semi-permanent firmware, which is stored in flash memory. Multi-Tech's firmware is nonvolatile; that is, it remains stored in memory when the modem is turned off and can be upgraded as new features are added. Multi-Tech's Flash Wizard can be downloaded from Multi-Tech’s FTP site and is available on CD. Use this Flash Wizard for upgrading your firmware. Documentation for using the Flash Wizard is included with the wizard.
Chapter 1 – Universal Socket Connectivity XMODEM Serial Port Upgrade or TFTP Ethernet Upgrade The SocketEthernet IP Module, for example, contains a 2 MB flash wherein the boot image, the firmware and configuration files are stored in a compressed format. The flash can easily be upgraded both locally as well as remotely. Serial Port Upgrade The flash of the SocketEthernet IP can be upgraded locally through serial port using the upload feature of serial applications.
Chapter 1 – Universal Socket Connectivity Ethernet Port Upgrade The flash can be upgraded remotely through the Ethernet using TFTP. The SocketEthernet IP Module flash contains two main files, which are required for an upgrade. 1. Binary File The binary file contains the firmware of the Module. The name of this binary file would be in the following format. MTXCSEM-TFTP-vw- 2. Gun-zipped http.tar.
Chapter 1 – Universal Socket Connectivity Multi-Tech Systems, Inc. Flash Programming Protocol This information is provided exclusively for the users of Multi-Tech Systems, Inc. modems. Such users Multi-Tech Systems, Inc. modem owners have the right to use, modify, and incorporate this code into other products provided they include the Multi-Tech Systems, Inc. notice and the associated copyright notice with any such product. Copyright (C) Multi-Tech Systems, Inc.
Chapter 1 – Universal Socket Connectivity Other Supported Boot Code Commands 2.1 2.2 ATI0 ATI1 - ATI4- returns 000 or 247 for ISDN returns boot code version number MM.mmn where MM = unique code for each different platform that has boot code mm = version number of boot code n = version letter of the boot code Examples: 2.05e, 2.12d, 35.15 Boot code date and time. Other Programming Concerns 1. 2. 3. 4. 5. 6. 7.
Chapter 1 – Universal Socket Connectivity Extended Address Record Char Pos Field Type Value Description 1 Record Start “:” 2-3 Data Byte Count “02” Always 2 bytes for this record type 4-7 Address “0000” Not used for this record type (must be zero) 8-9 Record Type “02” Extended Address Record 10-13 Extended Address “EEEE” Top 16 bits of 20 bit address, most significant byte first 14-15 Checksum “ZZ” Zero minus the two’s complement addition of all data hex values 16-17 End of Line “\r\n” Carriage Return foll
Chapter 1 – Universal Socket Connectivity Wireless Account Activation Multi-Tech – A Certified National Activation Agent Multi-Tech Systems, Inc. is a certified national AT&T and Sprint activation agent for AT&T and Sprint wireless.
Chapter 1 – Universal Socket Connectivity Verizon Account Setup and Activation Follow these steps to set up a wireless account: • • Contact Verizon to obtain an account. • Verizon will give you the phone number for each modem.
Chapter 1 – Universal Socket Connectivity Multi-Tech Warranty Statement Multi-Tech Systems, Inc., (hereafter “MTS”) warrants that its products will be free from defects in material or workmanship for a period of two, five, or ten years (depending on model) from date of purchase, or if proof of purchase is not provided, two, five, or ten years (depending on model) from date of shipment.
Chapter 1 – Universal Socket Connectivity Repair Procedures for International Customers (Outside U.S.A. and Canada) Your original point of purchase Reseller may offer the quickest and most economical repair option for your Multi-Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or other repair service for your Multi-Tech product. The Multi-Tech sales office directory is available at www.multitech.
Chapter 2 SocketModem MT5600SMI MT5656SMI Multi-Tech Systems, Inc.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Introduction The Multi-Tech SocketModem creates communication-ready devices by integrating data/fax/voice functionality into a single product design. The SocketModem is a space-efficient (1" × 2.5"), embedded modem that provides V.92 or V.34/33.6K data communication. The complete, ready-to-integrate modem dramatically reduces development time and costs for system designers.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Developer Kit A Developer Kit is available. The serial kit allows you to plug in the SocketModem and use it as a serial modem for testing, programming, and evaluation. The parallel kit turns the parallel module into an ISA modem. Each kit includes one SocketModem, one developer board with an RS-232 DB-25 connector, wall power adapter, RJ-11 jack, an RS232 cable, and a Developer Kit CD.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Category Intelligent Features Description Integrates the controller, data pump, and data access arrangement (DAA) in one module. Backward compatibility with lower speed data standards V.22bis Fast Connect FastPOS (V.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) SocketModem Configuration MT5600SMI Serial Configuration The serial interface use an 16-pin interface to provide an on-board DAA with tip and ring connections, audio circuit for call-progress monitoring and serial interface via logic level signals. Note: The bolded, shaded pins are the active SocketModem pins.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Parallel Configuration Note: The parallel configuration is not compatible with the serial universal socket. The parallel interface SocketModem uses a 22-pin interface to provide an on-board DAA with tip and ring connections, audio circuit for call-progress monitoring, and parallel interface.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Differences - Legacy Voice Modems and Current Modems Differences between the SFxxxD/SP and the MT5656SMI Note: The SFxxxD/SP is the legacy voice modem with speakerphone I/O. Pin 54 – “VC” This pin provided a reference voltage that is available from the data pump. This pin is not supported on the MT5656SMI SocketModem.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Electrical Characteristics 3.3 V Serial SocketModem 3.3 V DC Characteristics (TA = 0°C to 70°C; VDD = 3.3 V ± 0.3 V) VDDMAX = 3.6 V Inputs Input High –DTR (40), –TXD (35), –RTS (33), –RESET (24) Min 2.0 V Outputs Output High –DCD (39), –CTS (38), –DSR (37), –RI (36), –RXD (34) Min 2.4 V 2 mA, Z INT = 120 Ω Digital Input Capacitance Input Low Max 0.8 V Output Low Max 0.5 V 50pF 3.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Parallel Host Bus Timing Table Symbol t AS AH t CS t CH t RD t DD t DRH t t Parameter Min READ (See Notes) Address Setup 5 Address Hold 10 Chip Select Setup 0 Chip Select Hold 10 RD Strobe Width 45 Read Data Delay Read Data Hold 5 WRITE (See Notes) Address Setup 5 Address Hold 15 Chip Select Setup 0 Chip Select Hold 10 WT Strobe Width 75 Write Data Setup (see Note 4) Write Data Hold (see Note 5) 5 Max Units 25 - ns ns ns ns ns ns ns AS ns AH ns t CS
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) SocketModem Parallel Interface The modem supports a 16550A interface in parallel interface versions. The 16550A interface can operate in FIFO mode or non-FIFO mode. Non-FIFO mode is the same as the 16450-interface operation. FIFO mode’s unique operations are described in this chapter.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Register Functional Definitions The following table delineates the assigned bit functions for the twelve internal registers. The assigned bit functions are more fully defined in the following paragraphs. Internal Registers Register No. 7 6 5 4 3 2 2 1 (DLAB = 0) 0 (DLAB = 0) 0 (DLAB = 0) 1 (DLAB = 1) 0 (DLAB = 1) Register Name Scratch Register (SCR) Modem Status Register (MSR) 7 6 5 BIT No.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) IER – Interrupt Enable Register (Addr = 1, DLAB = 0) The IER enables five types of interrupts that can separately assert the HINT output signal (See the Interrupt Sources and Reset Control table in the IIR section of this chapter). A selected interrupt can be enabled by setting the corresponding enable bit to a 1, or disabled by setting the corresponding enable bit to a 0.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) FCR – FIFO Control Register (Addr = 2, Write Only) The FCR is a write-only register used to enable FIFO mode, clear the RX FIFO and TX FIFO, enable DMA mode, and set the RX FIFO trigger level. Bits 7-6 RX FIFO Trigger Level FCR7 and FCR6 set the trigger level for the RX FIFO (Receiver Data Available) interrupt.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) IIR – Interrupt Identifier Register (Addr = 2) The Interrupt Identifier Register (IIR) identifies the existence and type of up to five prioritized pending interrupts. Four priority levels are set to assist interrupt processing in the host. The four levels, in order of decreasing priority, are Highest: Receiver Line Status, 2: Receiver Data Available or Receiver Character Timeout. 3: TX Buffer Empty, and 4: Modem Status.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) LCR – Line Control Register (Addr = 3) The Line Control Register (LCR) specifies the format of the asynchronous data communications exchange. Bit 7 Divisor Latch Access Bit (DLAB) This bit must be set to a 1 to access the Divisor Latch Registers during a read or write operation. It must be reset to a 0 to access the Receiver Buffer, the Transmitter Buffer, or the Interrupt Enable Register.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) MCR – Modem Control Register (Addr = 4) The Modem Control Register (MCR) controls the interface with modem or data set. Bit 7-5 Not used Always 0 Bit 4 Local Loopback When this bit is set to a 1, the diagnostic mode is selected and the following occurs: 1. Data written to the Transmit Buffer is looped back to the Receiver Buffer. 2.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) LSR – Line Status Register (Addr = 5) This 8-bit register provides status information to the host concerning data transfer Bit 7 RX FIFO Error In the 16450 mode, this bit is not used and is always 0. In the FIFO mode, this bit is set if there are one or more characters in the RX FIFO with parity error, framing error, or break indication detected. This bit is reset to a 0 when the host reads the LSR and note of the above conditions exist in the RX FIFO.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) MSR – Modem Status Register (Addr = 6) The Modem Status Register (MSR) reports current state and change information of the modem. Bits 4-7 supply current state and bits 0-3 supply change information. The change bits are set to a 1 whenever a control input form the modem changes state from the last MSR read by the host. Bits 0-3 are reset to 0 when the host reads the MSR or upon reset.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) SCR – Scratch Register (Addr = 7) The Scratchpad Register is a read-write register at location 7. This register is not used by the modem and can be used by the host for temporary storage. Divisor Registers (Addr = 0 and 1, DLAB = 1) The Divisor Latch LS (least significant byte) and Divisor Latch MS (most significant byte) are two read-write registers at locations 0 and 1 when DLAB = 1, respectively.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Application Notes Tip and Ring Interface Main Board Filtering Multi-Tech Systems, Inc.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Microphone and Speaker Note: Applies to the MT5656SMI only. Microphone Input Option Speaker Output Option 1 Speaker Output Option 2 Multi-Tech Systems, Inc.
Chapter 2 – SocketModem (MT5600SMI & MT5656SMI) Recommended Parts Disclaimer: Multi-Tech Systems makes no warranty claims for vendor product recommendations listed below. Other vendor products may or may not operate satisfactorily. Multi-Tech System’s recommended vendor products only indicate that the product has been tested in controlled conditions and were found to perform satisfactorily. Surface mount ferrites are used on T&R (Tip and Ring) to mitigate emission levels out the RJ-11 cable.
Chapter 3 SocketModem MT5634SMI-34 MT5634SMI-92 Multi-Tech Systems, Inc.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Introduction Multi-Tech’s SocketModem creates communication-ready devices by integrating data/fax/voice functionality into a single product design. The SocketModem is a space-efficient (1" × 2.5"), embedded modem that provides V.92/56K communication. The complete, ready-to-integrate modem dramatically reduces development time and costs for system designers.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Technical Specifications The SocketModem meets the following specifications: Category Description Client-to-Server Data Rates Supports V.92 and V.90 data rates AGC Dynamic Range 43 dB Cleaning No cleaning/washing due to the manufacturing process used to produce this product.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Category Description Receiver Sensitivity –43 dBm under worst-case conditions Serial Speeds Serial port data rates adjustable to 300, 1200, 2400, 4800, 9600, 19,200, 38,400, 57,600, 115,200, and 230,400 bps Storage Temperature –50 to +100° C Transmit Level –11 dBm (varies by country setting) Voice Compatibility TAM (Telephone Answering Machine): S-101 AT+V commands (no CODEC for speakers/microphone interface) Weight 0.02 Kg. (0.04 lb.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) SocketModem Configuration Serial Configuration The MT5634SMI SocketModem uses a 20-pin interface to provide an on-board DAA with tip and ring connections, audio circuit for call-progress monitoring, LED driver for call status annunciation, and serial interface. Note: The bolded, shaded pins are the active MT5634SMI pins. Serial SocketModem Pinout Multi-Tech Systems, Inc.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Parallel Configuration The parallel configuration is not compatible with the serial universal socket. The MT5634SMI-P (Parallel) SocketModem uses a 22-pin interface to provide an on-board DAA with tip and ring connections, audio circuit for call-progress monitoring, and parallel interface. Note: The bolded, shaded pins are the active MT5634SMI-P (Parallel) pins.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Electrical Characteristics 3.3 V Serial – Industrial Temperature (SMI-ITP) Build Option 3.3 V DC Characteristics (TA = -40 °C to 85 °C; VDD = 3.3 V ± 0.3 V) VDDMAX = 3.6 V Digital Inputs –DTR (40), –TXD (35), –RTS (33) –Reset (24) Digital Outputs –DCD (39), –CTS (38), –DSR (37), –RI (36), –RXD (34) Digital Input Capacitance Input High Min 2.52 V Input High Min 2.52 V Output High Min. 2.3 V Input Low Max 0.9 V Input Low Max 0.3 V Output Low Max 0.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Timing Requirements Timing Requirements for Parallel Write Parameter –DS to –WR Setup (low to low) A0, A1, A2 to –WR Setup (valid to low) –WR Pulse Width (low to high) D0–D7 to –WR Setup (valid to high) –WR to –DS hold (high to high) –WR to A0–A2 Hold (high to invalid) –WR to D0–D7 Hold (high to invalid) –WR interaccess (high to low) Non-MIMIC Accesses MIMIC Accesses Min 10 15 40 30 0 0 0 Max - Unit ns ns ns ns ns ns ns 10 110 - ns ns Min 10 15 4
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) SocketModem Parallel Interface Internal Registers The SocketModem parallel interface is a mimic of a 16C550A UART. It is similar to the MIMIC interface used in the Zilog Z80189. The SocketModem mimic (MMM) takes advantage of this standard interface while replacing the serial to parallel data transfer with a less complicated parallel to parallel data transfer. The MMM interface controls an 8-bit parallel data transfer which is typically interrupt driven.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) A typical (interrupt driven) write to the RX block is a two-step process. The MMM micro-controller must first write the 3 error bits to a shadow MMM LSR status register. Next, the micro-controller writes the data to the RX FIFO and during this write operation, the 3 error bits are directly loaded from the LSR shadow register into the bits 810 of the selected (11 bit-wide) FIFO register.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Time Out Interrupts The interrupts are enabled by IER bits 0-3. Care must be taken when handling these interrupts. Following a reset the transmitter interrupt is enabled, the SocketModem will issue an interrupt to indicate that transmit holding register is empty. This interrupt must be serviced prior to continuing operations. The LSR register provides the current singular highest priority interrupt only.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) RBR – Receive Buffer (RX FIFO) All eight bits are used for receive channel data (host read/data in; host write/data out). The three error bits per byte are copied into bits 2, 3, and 4 of the LSR during each host I/O read; therefore, they are available for monitoring on a per-byte basis. THR – Transmit Holding Register (TX FIFO) All eight bits are used for transmit channel data (host write/data out; host read/data in).
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) FCR – FIFO Control Bits 6–7: Bit 5: Bit 4: Bit 3: Used to determine RX FIFO trigger levels. Used to detect a change in the FCR. TX FIFO overrun bit. DMA mode select. If bit 3 is a 0, the 16450 mode is enabled which does only single-byte transfers. When bit 3 is a 1, it enables a multiple byte (FIFO mode) data transfer. Bit 2: TX FIFO reset. This will cause TX FIFO pointer logic to be reset (any data in TX FIFO will be lost).
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) LSR – Line Status Bit 7: Error in RX FIFO. This bit is always set to 1 if at least one data byte in the RX FIFO has an error. This will clear when there are no more errors in the RX FIFO. Bit 6: Transmitter empty. This bit is the same as LSR bit 5 (THRE) in MMM Bit 5: Transmitter holding register empty.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) SCR – Scratch The host programmer uses this register for temporary data storage. DLL – Divisor Latch (LSByte) This register contains low-order byte for the 16-bit clock divider. It is kept to maintain register set compatibility with the 16C550A interface. However, it is not used for clock generation since MMM does not require the generation of a real baud clock.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Application Notes Tip and Ring Interface Main Board Filtering Multi-Tech Systems, Inc.
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92) Recommended Parts Disclaimer: Multi-Tech Systems makes no warranty claims for vendor product recommendations listed below. Other vendor products may or may not operate satisfactorily. Multi-Tech System’s recommended vendor products only indicate that the product has been tested in controlled conditions and were found to perform satisfactorily. Surface mount ferrites are used on T&R (Tip and Ring) to mitigate emission levels out the RJ-11 cable.
Chapter 4 SocketModem MT2456SMI-22 Multi-Tech Systems, Inc.
Chapter 4 – SocketModem (MT2456SMI-22) Chapter 4 – SocketModem (MT2456SMI-22) Introduction The Multi-Tech SocketModem supports analog data modem operation with V.22bis Fast Connect, V.42bis data compression, and V.80 synchronous access mode. The SocketModem is a space-efficient (1" × 2.5"), embedded modem that is ready-to-integrate into your applications; therefore, dramatically reducing development time and costs for system designers.
Chapter 4 – SocketModem (MT2456SMI-22) Technical Specifications The SocketModem meets the following specifications: Category Description Client-to-Server Data Rates V.22 bis Client-to-Client Data Rates 2400, 1200, 0-300 bps Data Format Serial, asynchronous Modem Compatibility V.22bis, V.22; Bell 212A and 103/113; ITU-T V.21 & V.23 Error Correction ITU-T V.42 (LAP-M or MNP 2–4) Data Compression ITU-T V.
Chapter 4 – SocketModem (MT2456SMI-22) Category Description Approvals Safety Certifications UL60950 cUL60950 EN60950 IEC60950 ACA TS001 / AS 3260 CCC EMC Approvals FCC Part 15 (Class B) Canadian EMC (Class B) EN 55022 (Class B) EN 55024 TIA-602 AT command compatible V.22bis fast connect Supports V.
Chapter 4 – SocketModem (MT2456SMI-22) SocketModem Configuration Serial Configuration The MT2456SMI-22 SocketModem with a serial interface use a 16-pin interface to provide an on-board DAA with tip and ring connections, audio circuit for call-progress monitoring and serial interface via logic level signals. Note: The bolded, shaded pins are active Mt2456SMI-22 pins. Serial SocketModem Pinout Multi-Tech Systems, Inc.
Chapter 4 – SocketModem (MT2456SMI-22) Electrical Characteristics 3.3 V and 5 V Serial SocketModem 3.3 V DC Characteristics (TA = 0°C to 70°C; VDD = 3.3 V ± 0.3 V) VDDMAX = 3.6 V 5 V DC Characteristics (TA = 0°C to 50°C; VDD = 5 V ± 0.25 V) VDDMAX = 5.25 V Inputs Input High Input Low –DTR (40), –TXD (35), –RTS (33), –RESET (24) Min 2.0 V Max 0.8 V Outputs Output High Output Low –DCD (39), –CTS (38), –DSR (37), –RI (36), –RXD (34) 2mA, Z INT = 120 Ω Min 2.4 V Max 0.
Chapter 4 – SocketModem (MT2456SMI-22) Applications Notes Tip and Ring Interface Main Board Filtering Multi-Tech Systems, Inc.
Chapter 4 – SocketModem (MT2456SMI-22) Recommended Parts Disclaimer: Multi-Tech Systems makes no warranty claims for vendor product recommendations listed below. Other vendor products may or may not operate satisfactorily. Multi-Tech System’s recommended vendor products only indicate that the product has been tested in controlled conditions and were found to perform satisfactorily. Surface mount ferrites are used on T&R (Tip and Ring) to mitigate emission levels out the RJ-11 cable.
Chapter 5 SocketModem IP MT2456SMI-IP Multi-Tech Systems, Inc.
Chapter 5 – SocketModem IP (MT2456SMI-IP) Chapter 5 – SocketModem IP (MT2456SMI-IP) Introduction The Multi-Tech SocketModem IP integrates dial-up PSTN modem functionality and a complete TCP/IP protocol stack into a single product design. The SocketModem IP is a complete ready-to-integrate module that embeds Internet protocols inside your product device allowing it to send and receive data over the Internet without connecting to a PC or gateway server. The space efficient (1” x 2.
Chapter 5 – SocketModem IP (MT2456SMI-IP) Technical Specifications Category Description Data Format Serial, asynchronous Flash Memory 2 MEG Client-to-Client Data Rates 33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200, 16,800 bps 14,400, 12,000, 9600, 7200, 4800 bps 2400, 1200, 0-300 bps Data V.92; V.34, V.32, V.32bis, V.22 Error Correction V.42 (LAP-M or MNP 2–4) Data Compression V.44, V.
Chapter 5 – SocketModem IP (MT2456SMI-IP) Category Description Telephony/TAM TAM (Telephone Answering Machine) In modem (transparent) mode V.253 commands: V.
Chapter 5 – SocketModem IP (MT2456SMI-IP) SocketModem Configuration Serial Configuration The SocketModem IP use a 16-pin interface to provide an on-board DAA with tip and ring connections, audio circuit for call-progress monitoring and serial interface via logic level signals. Note: 5 Volt Tolerant Signal Inputs are –DTR –TXD, –RTS and –RESET. Drawing Note: The bolded, shaded pins are the SocketModem IP pins. SocketModem IP Pinout Multi-Tech Systems, Inc.
Chapter 5 – SocketModem IP (MT2456SMI-IP) Electrical Characteristics 3.3 V Serial 3.3 V DC Characteristics (TA = -40 °C to 85 °C; VDD = 3.3 V ± 0.3 V) VDDMAX = 3.6 V Digital Inputs –DTR (40), –TXD (35), –RTS (33) Note: These digital inputs are 5 volt tolerant Digital Inputs –RESET (24) Note: These digital inputs are 5 V tolerant Digital Outputs –DCD (39), –CTS (38), –DSR (37), –RI (36), –RXD (34) Input High Min 2.52 V Input Low Max 0.8 V Input High Min. 2.52 V Input Low Max. 0.3 V Output High Min. 2.
Chapter 5 – SocketModem IP (MT2456SMI-IP) Application Notes Tip and Ring Interface Main Board Filtering Multi-Tech Systems, Inc.
Chapter 5 – SocketModem IP (MT2456SMI-IP) Recommended Parts Disclaimer: Multi-Tech Systems makes no warranty claims for vendor product recommendations listed below. Other vendor products may or may not operate satisfactorily. Multi-Tech System’s recommended vendor products only indicate that the product has been tested in controlled conditions and were found to perform satisfactorily. Surface mount ferrites are used on T&R (Tip and Ring) to mitigate emission levels out the RJ-11 cable.
Chapter 6 SocketEthernet IP MTXCSEM Multi-Tech Systems, Inc.
Chapter 6 – SocketEthernet IP (MTXCSEM) Chapter 6 – SocketEthernet IP (MTXCSEM) Introduction The Multi-Tech SocketEthernet IP is a complete, ready to integrate serial-to-Ethernet module for connecting legacy devices to an IP network for remote monitoring, control and configuration. The space efficient module (1” x 2.5”) provides a high performance Ethernet bridge as well as a complete TCP/IP protocol stack into a single, universal socket design.
Chapter 6 – SocketEthernet IP (MTXCSEM) Technical Specifications Category Description Processor 150 MHz, ARM 9 Memory 8 MEG byte Flash Memory 2 MEG byte Board Dimensions 1.045” w x 2.541” h x 0.680” d; 0.6 oz. (2.65cm x 6.45cm x 1.7cm; 0.017 kg.) Weight 0.602 lb. (0.017 kg.
Chapter 6 – SocketEthernet IP (MTXCSEM) Category Description Approvals Safety Certifications UL60950 EN60950 IEC60950 ACA TS001 / AS 3260 EMC Approvals FCC Part 15 Canadian EMC EN 55022 EN 55024 Serial interface supports DTE speeds to 230K bps High performance 10/100BaseT Ethernet bridge High performance processor runs ARP, DHCP client, ICMP, IP, PPP, TCP, Telnet, TFTP, HTTP server, SMTP client, POP3 client, and PPP compression.
Chapter 6 – SocketEthernet IP (MTXCSEM) SocketModem Configuration Serial Configuration The SocketEthernet IP uses a 23-pin interface to provide an on-board Ethernet media access controller, an Ethernet physical layer (without the RJ-45 jack), an LED driver for Ethernet monitoring, and a serial interface. Note: The shaded, bolded pins are SocketEthernet IP active pins. SocketEthernet IP Pinout Electrical Characteristics 3.3 V Serial 3.3 V DC Characteristics (TA = -40 °C to 85 °C; VDD = 3.3 V ± 0.
Chapter 6 – SocketEthernet IP (MTXCSEM) Application Notes Ethernet Interface – Non-Isolated Design Note: VREF stands for Power in this drawing. Ethernet Interface – Isolated Design Isolated Design Application Note The MTXCSEM – HV was designed to meet Basic Isolation at 240Vac according to the international medical directive for safety (EN60601-1). The recommended components for an isolated design comply with the same standard.
Chapter 7 SocketModem ISDN MT128SMI Multi-Tech Systems, Inc.
Chapter 7 – SocketModem ISDN (MT128SMI) Chapter 7 – SocketModem ISDN (MT128SMI) Introduction The Multi-Tech SocketModem ISDN creates communication-ready devices by integrating BRI ISDN functionality and S/T interface into a single, universal socket design. The space-efficient (1” x 2.5”) embedded modem provides bidirectional communication bandwidth of up to 128K bps. This complete, ready-to-integrate modem dramatically reduces development time and costs for system designers.
Chapter 7 – SocketModem ISDN (MT128SMI) Technical Specifications Category Description ISDN Interface Service: 2B+D Interface (BRI) Interface: Four-wire S/T-type interface Rate: 64K bps/1 B-channel; 128K bps/2-channel; 16K bps/D-channel (for signaling) Sync or async (sync on one B-channel) U.S. National ISDN-1, AT&T 5ESS Custom, Northern Telecom DMS-100 Custom, ETSI/DSS1/NET3 (Euro ISDN), Japan NTT INS64, France VN-4 PPP, ML-PPP, MP+, V.120, X.
Chapter 7 – SocketModem ISDN (MT128SMI) SocketModem ISDN Configuration Serial Configuration The MT128SMI SocketModem uses a 23-pin interface. Note: The bolded, shaded pins are the MT128SMI active pins. SocketModem ISDN Pinout Multi-Tech Systems, Inc.
Chapter 7 – SocketModem ISDN (MT128SMI) Electrical Characteristics 3.3 V and 5 V Serial SocketModem ISDN 3.3 V DC Characteristics (TA = 0°C to 70°C; VDD = 3.3 V ± 0.3 V) VDDMAX = 3.6 V 5 V DC Characteristics (TA = 0°C to 50°C; VDD = 5 V ± 0.25 V) VDDMAX = 5.25 V Inputs –DTR (40), –TXD (35), –RTS (33) –RESET (24) RX+, RX- (S/T Interface Receive) Input Capacitance Outputs –DCD (39), –CTS (38), –DSR (37) –RI (36), –RXD (34), TCLK (11), RCLK (12) TX+, TX- (S/T Interface Transmit) Input High Min 2.0 V Min 2.
Chapter 7 – SocketModem ISDN (MT128SMI) MT128SMI Developer Board Multi-Tech Systems, Inc.
Chapter 7 – SocketModem ISDN (MT128SMI) MT128SMI Schematics Multi-Tech Systems, Inc.
Chapter 7 – SocketModem ISDN (MT128SMI) Multi-Tech Systems, Inc.
Chapter 7 – SocketModem ISDN (MT128SMI) Multi-Tech Systems, Inc.
Chapter 7 – SocketModem ISDN (MT128SMI) Multi-Tech Systems, Inc.
Chapter 8 SocketModem GPRS MTSMC-G Multi-Tech Systems, Inc.
Chapter 8 – SocketModem GPRS (MTSMC-G) Chapter 8 – SocketModem GPRS (MTSMC-G) Product Description The Multi-Tech SocketModem GPRS is a complete, ready-to-integrate, embedded wireless modem. Designed for global use, it offers standards-based multi-band GSM/GPRS Class 10. The SocketModem GSM/GPRS is based on industry-standard open interfaces and utilizes the same form factor as the SocketModem, SocketModem IP, or SocketEthernet IP modules from Multi-Tech.
Chapter 8 – SocketModem GPRS (MTSMC-G) Technical Specifications The SocketModem GPRS meets the following specifications: Category Description Data Speed Packet data up to 85K bps Circuit-switched data (GSM/GPRS) up to 14.4K bps transparent and non-transparent Interface Serial interface supports DTE speeds to 115.2K Data Compression V.42bis data compression Fax Compatibility GSM/GPRS Class 1 and Class 2 Group 3 Fax Dimensions 3.1” w x 1.4” h x 0.5” d (8.0 cm x 3.5 cm x 1.
Chapter 8 – SocketModem GPRS (MTSMC-G) Mechanical Dimensions SocketModem GSM/GPRS Mechanical Drawing Multi-Tech Systems, Inc.
Chapter 8 – SocketModem GPRS (MTSMC-G) SocketModem Configuration Serial Configuration The SocketModem GSM/GPRS uses a 13-pin interface. Note: The bolded, shaded pins are the SocketModem GSM/GPRS active pins. SocketModem Pinout Multi-Tech Systems, Inc.
Chapter 8 – SocketModem GPRS (MTSMC-G) Electrical Characteristics 5 V DC Characteristics (TA = -20° C to 55° C; VDD = 5 V ± 0.25 V) VDDMAX = 5.25 V Digital Inputs –DTR (40), –TXD (35), –RTS (33), –RESET (24) Digital Outputs –DCD (39), –CTS (38), –DSR (37), –RI (36), –RXD (34) Digital Input Capacitance Input High Min 3.675 V Output High Min. 4 V Input Low Max .7 V Output Low Max 0.
Chapter 8 – SocketModem GPRS (MTSMC-G) SIM Interface Electrical Characteristics Parameter Conditions Minimum SIMDATA VIH IIH = +/- 20µA 0.7xSIMVCC SIMDATA VIL IIL = 1 mA SIMRST, SIMDATA SIMCLK VOH Source current = 20µA SIMRST, SIMDATA SIMCLK VOL Sink current = -200µA Typical Maximum Unit V 0.3xSIMVCC SIMVCC – 0.1V V V 0.1 SIMVCC Output Voltage ISIMVCC <= 6mA 2.85 V SIMCLK Rise/Fall Time SIMRST, SIMDATA Rise/Fall Time Loaded with 30pF 2.70 2.
Chapter 8 – SocketModem GPRS (MTSMC-G) Application Notes SocketModem GSM/GPRS Interfaces • • • Flashing LED SIM Interface RF Interface Flashing LED Interface The flashing LED signal is used to indicate the working mode of the SocketModem.
Chapter 8 – SocketModem GPRS (MTSMC-G) General Guidelines for the Use of the SocketModem Hardware and RF • • • Ground plane: Multi-Tech recommends having a common ground plane for analog, digital, and RF grounds. ESD protection on serial link. Possible spurious emission radiated by the application to the RF receiver in the receiver band The Antenna The antenna sub-system and integration in the application is a major issue: Choice of antenna cable (type, length, performances, thermal resistance, etc.
Chapter 8 – SocketModem GPRS (MTSMC-G) MMCX Plug The SocketModem requires an MMCX plug to connect to an antenna. MMCX Connector Example (right angle type) MMCX / SMA Adapter A small MMCX / SMA adapter can be ordered, for example, from: Amphenol http://www.amphenol.com/ Order No: 908-31100 Antenna Cable An optional 6” antenna cable can be ordered from Multi-Tech Systems, Inc. 6-Inch Antenna Cable – SMA Jack to MMCX Plug Multi-Tech Systems, Inc.
Chapter 9 SocketModem CDMA MTSMC-C Multi-Tech Systems, Inc.
Chapter 9 – SocketModem CDMA (MTSMC-C) Chapter 9 – SocketModem CDMA (MTSMC-C) The Multi-Tech SocketModem CDMA is a complete, ready-to-integrate, embedded wireless modem. Designed for global use, it offers standards-based multi-band CDMA200 1x performance. The SocketModem CDMA is based on industry-standard open interfaces and utilizes Multi-Tech’s universal socket design. Notes about Activation: • • • These units are shipped without network activation.
Chapter 9 – SocketModem CDMA (MTSMC-C) Technical Specifications The SocketModem CDMA meets the following specifications: Category Description Data Speed Packet data up to 85K bps Circuit-switched data up to 14.4K bps Interface Serial interface supporting DTE speeds to 230K Fax Compatibility CDMA Class 2.0 Group 3 Fax Dimensions 3.1” w x 1.4” h x 0.5” d (8.0 cm x 3.5 cm x 1.2 cm) Weight 1.
Chapter 9 – SocketModem CDMA (MTSMC-C) Mechanical Dimensions SocketModem CDMA Mechanical Drawing Multi-Tech Systems, Inc.
Chapter 9 – SocketModem CDMA (MTSMC-C) SocketModem Configuration Serial Configuration The SocketModem CDMA uses a 13-pin interface. Note: The bolded, shaded pins are the SocketModem CDMA active pins. SocketModem CDMA Pinout Electrical Characteristics Electrical characteristics for the 5V Serial SocketModem are presented in this chapter. 5 Vdc Characteristics (TA = -20° C to 55° C; VDD = 5 V ± 0.25 V) VDDMAX = 5.25 V Digital Inputs Input High Input Low –DTR (40), –TXD (35), –RTS (33), –RESET (24) Min 3.
Chapter 9 – SocketModem CDMA (MTSMC-C) Application Notes SocketModem Interfaces Flashing LED Interface The flashing LED signal is used to indicate the working mode of the SocketModem. LED and SocketModem Status Signal OFF ON SocketModem Status Download mode or switched OFF> Continuously lit Switched ON (not registered on the network) Flashing Switched ON (registered on the network) RF Interface The impedance is 50 Ohms nominal. RF Connector The RF connector is MMCX standard type.
Chapter 9 – SocketModem CDMA (MTSMC-C) Sources for Peripheral Devices CDMA Antenna The integrated modem antenna connector is a MMCX connector. The MMCX connector incorporates a 'Snap On' latching action in order to make the connection easier with an excellent RF performance. An additional advantage is its small physical size, which is 50% of the standard MCX connector. This type of connector is suitable for the standard ranges of flexible and semi-rigid cables.
Chapter 10 SocketWireless Bluetooth MTS2BTSMI Multi-Tech Systems, Inc.
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Introduction The Multi-Tech Systems, Inc. SocketWireless with Bluetooth-enabled technology allows developers to establish wireless networks using a special set of AT commands and a developer board. The SocketWireless with Bluetooth technology makes the cable-replacement transition to wireless networks seamless and easy.
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Technical Specifications Category Description Serial Interface Supports speeds from 1200bps to 920Kbps RF Interface Frequency………………2402 – 2480MHz Modulation……………...FHSS/GFSK Channel Intervals………1MHz Number of Channels….79CH Transmission Rate…….
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Category Description Intelligent Features Can be configured, commanded, and controlled through simple ASCII strings over the Bluetooth RF link or directly through the hardware serial UART. Low power consumption. Secure and robust communication link.
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Mechanical Dimensions SocketWireless Bluetooth Mechanical Drawing Multi-Tech Systems, Inc.
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) SocketWireless Bluetooth Configuration Serial Configuration The MT2BTSMI SocketWireless uses a 17-pin interface. Note: The bolded, shaded pins are the active SocketWireless pins. SocketWireless Bluetooth Pinout Electrical Characteristics 3.3 V and 5 V Serial SocketWireless Inputs Input High Input Low –DTR (40), –TXD (35), –RTS (33) Min 2.0 V Max 0.8 V –RESET (24) Min 2.0 V Max 0.
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Application Notes Example of a Master Discovery/Connection Sequence From Power Up and No Connection 1. Verify local device is Master in Data Mode. Sent: ATSi,7 Reply: 1,1,0,0 2. If not Master, set to Master and Data Mode. Sent: ATSW25,1,1,0,0 Reply: OK 3. Perform an Inquiry to obtain BT_Addresses (unless it is already known).
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Example of a Slave Command Sequence From Power Up: 1. Check and verify Communication to Slave. Sent : AT Reply:OK 2. Get information on Slave Bluetooth address. Sent : ATSi,1 Reply: 12-digit address OK 3. Set Slave to automatically connect in Fast Data Mode on Bluetooth connection. Sent : ATSW25,0,0,0,0 Reply:OK 4. Either cycle power or send ATURST.
Chapter 10 – SocketWireless Bluetooth (MTS2BTSMI) Sources for Peripheral Devices Antenna Requirements Frequency Range Impedance VSWR Gain Radiation Polarization Wave Connector 2.4-2.5 Ghz 50 ohm nominal <2.0:1 2 dBi Omni Vertical Half Wave Dipole SMA Plug (male) Antenna An antenna that meets the requirements for use with the SocketWireless product can be ordered, for example, from Nearson. www.nearson.com Multi-Tech Systems, Inc.
Index Index 5 5 V/3.3 V Jumper .....................................................17 A AT Commands Reference Guides .............................9 AT&T wireless ..........................................................36 B Bluetooth Configurations, Changing.......................135 Bluetooth technology..............................................129 C Cleaning Safety Standards ....................................126 Cleaning the Wireless SocketModem ....................
Index Pin Configurations MT128SMI (ISDN) ..............................................104 MT2456SMI-22.....................................................83 MT2456SMI-IP .....................................................91 MT5600SMI ..........................................................44 MT5634SMI ..........................................................66 SocketEthernet IP.................................................99 SocketModem GSM/GPRS ................................