Specifications

APPLICATION NOTE
Using the SUTRON RADAR LEVEL CONTROLLER (RLR-0002-1) with a MULTI-MODEM GPRS
(Wireless Modem MTCBA-G-F4)
19
4.2 MTCBA-G-F4 (RS-232 15-Pin Connector Pinout)
The Wireless Modem has a DE15-serial connector incorporated which includes a RS-232 interface link, audio link,
Boot and reset. This connector allows for access to the command line interface using a terminal program such as
HyperTerminal of Windows. The following table shows the pin assignment.
PIN EIA CCIT Designation
RS-232
1
DCD 109 Data Carrier Direct
6 RX 104 Receive Data (out)
2 TX 103 Transmit Data
8 DTR 108.2 Data Terminal Ready
9 GND Signal Ground
7 DSR 107 Data set ready
12 RTS 105 Request to Send
11 CTS 106 Clear to Send
13 RI 125 Ring Indicator
Audio 4 MIC (+)
5 MIC(-)
10 SPEAKER(+)
15 SPEAKER(-)
Boot 3 BOOT For factory use only
Reset 14 RESET To reset, connect toGND
momentarily
(Typical: 2mSec). Open for normal
operation.