User's Guide

Page 19
Equipment Installation
2.5 Powering Up and Testing
CS100 LED Display
When the CS100 Base Station is receiving a supply of power, the LED
display will give you basic information as to its status.
Green Normal operation
Red Fault
Flashing red Subscription mode
Testing Base Station / Repeater Signal Coverage
The radio coverage provided by the CS100 Base Station can be tested by
using one or more handsets which has been registered to the system
(See section 3.1 – ‘Registering the Master Handset’).
When carrying out this test, the handset must be ‘Off Hook’ in field-test
mode. To set the handset to this mode, press “
*
99981
*
” followed by OK.
The display will now change to show the following:
RPN The first number is the Base Station / Repeater that the handset is in
communication with. The second number is the current preferred choice
Repeater for handover of a call if the user is moving. These numbers will
change as you move around.
Q52 This is the audio quality indicator. A number between 60 and 64 is
acceptable, with 64 being the best. Anything below 60 and the audio quality
may deteriorate.This should also be checked by setting up a voice connec-
tion to check the speech quality.
RSSI This stands for Received Signal Strength Indicator, and is a
measure of the received signal from the Base Station or Repeater. This is
used to determine when to ‘Hand Over a call. These readings are relative
to each handset, and so variations between handset readouts are normal.
RPN: 00 02
Q52: 64
RSSI: 55 40